7
Installation of Light controllers
For lament light bulbs, low energy bulbs, LED (110-
220V), uorescent tubes, dichroic bulbs (110-220V).
1. Dismantle the frame. If you use the light and tempera-
ture sensor, at least one blind module is required.
2. Identify the return conductor of the lamps and the line
or phase cable, using a voltage tester screwdriver. If you
can’t nd one, add a neutral cable, which will be neces-
sary for the performance of the controller.
-OPTIONAL-
3. Take the blind module o the frame and make a
20mm hole in the middle with the holesaw. A power
driver is recommended for this.
4. Disconnect the sensor’s module from the light
switch controller and press it onto the hole of the blind
module. We recommended gluing it in place with silico-
ne or multipurpose glue.
Extreme care: handling objects with electrical
voltage! Danger of electrocution!
Proceed only trained electrician or other suitably
qualied person. We recommend placing the
controller next to the light switch.
Installation of Light controllers |