SAFETY WARNINGS
• Installation should only be arried out by
ompetent and authorised personnel and in
a ordan e with the instru tions in this manual.
• Only make ele tri al onne tions when the devi e
is isolated from the main supply.
• If “Automati Start” is sele ted be aware that
safety output onta ts will swit h immediately
after the power supply is onne ted.
• Opening the devi e will void the warranty. Never
attempt to repair any devi e.
• Adhere to Safety Che ks.
• DO NOT DEFEAT, TAMPER, OR BYPASS THE
SAFETY FUNCTION. FAILURE TO DO SO CAN
RESULT IN DEATH OR SERIOUS INJURY.
• L'installation doit être effe tuée par un personnel
ompétent et autorisé et en onformité ave les
instru tions de e manuel.
• faites uniquement des onnexions éle triques lorsque
l'appareil est isolé de l'alimentation prin ipale.
• Si "Démarrage automatique" est séle tionné être ons ient
que les onta ts de sortie de sé urité passeront
immédiatement après l'alimentation est onne tée.
• Ouverture de l'appareil annule la garantie. Ne jamais tenter
de réparer tout appareil.
• Adhérer à des ontrôles de sé urité.
NE DÉFAITE PAS, SABOTAGE, OU DE CONTOURNER LA
FONCTION DE SÉCURITÉ. MANQUEMENT À S'Y PEUT
ENTRAÎNER LA MORT OU DES BLESSURES GRAVES
Installation and Maintenan e Information Regarding UL 508
Installation should as per EN 60204-1 in addition to any local
regulations. The safety relay should be mounted inside a
cabinet enclosure and on a 35mm DIN rail according to DIN
EN 60715. No maintenance is required, there are no
serviceable parts. (Refer to Safety Chec s). The product is
designed to be a component of a customised safety
orientated control system. It is the responsibility of the user
to ensure the correct overall functionality of its systems and
machines. IDEM, its subsidiaries and affiliates, are not in a
position to guarantee all of the characteristics of a given
system or product not designed by IDEM.
Pilot Duty R300, B300
Single contact must be used
250V AC/DC / 6,0A
Resistive
Single contact must be used
250V AC/DC 6,0A
General Purpose
All contact at once can be used
USE COPPER OR COPPER-CLAD ALUMINUM CONDUCTORS
Maximum surround air temperature 40°C
Safety Che ks:
1. Ensure the appropriate safety level is achieved for the application function.
2.
The safety functions must be tested regularly. For applications were infrequent use is foreseeable, the system must have a manual function
test. At least once per month for PLe Cat3/4 or once per year for PLd Cat3 (ISO13849-1 / ISO14119).
De laration of Conformity
Manufacturer: IDEM SAFETY SWITCHES Ltd.
2 Ormside Close, Hindley Industrial Estate, Hindley Green, Wigan, WN2 4HR, UK
Product: Safety Emergency Stop De ices
Model types: SCR-73-i
The abo e products conform to the safety requirements of the following directi es and standards:
Machinery Directi e 2006/42/EC
EMC Directi e 2004/108/EC
Low Voltage Directi e 2006/95/EC
EN 13849-1:2008+AC:2009
EN 13849-2:2012
EN 62061:2005+AC:2010+A1:2013
EN 61508 (Parts 1-7): 2011-02
EN 60204-1:2006+A1:2009+AC:2010
EN 50178:1997
Third Party Certification: NB 0035 TUV Rheinland Industrie Ser ice GmbH