3 Setting and Wiring 4 Menu Sheet1 Overview 2 Operation Specications
1-3
Setting Parameters (WB1F)
1. 5 Setting Parameters (WB1F)
The setting parameters and setting values necessary for the PLC connection are as follows:
Adjust the setting according to the using environment.
zAll the settings of the WB1F should be performed before using the PLC connection.
zWhen the device of setting the WB1F (as PC) is dierent from the device to be connected through the PLC
connection, prepare a cable supporting both devices.
zDo not access or change any settings that are not listed here.
zDo not access or change any settings in reserved areas.
zWhen the setting values have been changed, save the setting value by “Save Set Values”on the control com-
mand.
Turning OFF the power, resetting, or changing the operation mode without performing “Save Set Values”will
return to the setting value that existed before change.
When conguring settings that specify ASCII code for the setting value, be aware of the following points.
zNUL (00H) cannot be used as a setting value.
zThe characters up to the rst NUL (00H) are considered the data and any data after that is not valid.
Setting value (hex) of bold face is default value (Setting at the time of factory shipments).
Item Sub item Address
(hex)
Size
(dec)
Default
(hex)
Setting value
(hex) Remarks
RS-232 setting
Communication
speed 0100 1 03
00 : 1,200bps
01 : 2,400bps
02 : 4,800bps
03 : 9,600bps
04 : 19,200bps
05 : 38,400bps
06 : 57,600bps
07 : 115,200bps
0a : 600bps
After saving, the settings are
reected when the power is
turned on, the WB1F is reset,
or the operation mode is
changed.
Data length 0101 1 01 00 : 7bits
01 : 8bits
Parity 0102 1 01
00 : NONE
01 : EVEN
02 : ODD
Stop bits 0103 1 00 00 : 1bit
01 : 2bits
Flow control 0104 1 00 00 : NONE
01 : CTS/RTS
PLC
Connection
Function enabled 06C0 1 00 00 : Disabled
01 : Enabled
If enabled, it will begin
the process to establish a
connection with connected
external devices at start up.
New settings will be reected
after saving and resetting the
device.
Protocol Select 06C1 1 00 00 : MC Protocol Format
4 4C (Q,L Series)
Select the communication
protocol of the external device
that is to be connected to the
WB1F.
Monitoring cycle 06C2 1 0A 01 - FF : Setting Value × 10ms
(10ms to 2,550ms)
Congure the monitoring
interval for the special area.
Timeout 06C3 1 14 01 - FF :
Setting Value × 100ms
(100ms to 25,500ms)
Configures response timeout
from a PLC.