ACAM Trouble Shooting Guide ACAM Trouble Shooting Guide
This is the ACAM Troubleshooting Guide. When used in conjunction with IDEAL
ACAM Set-up and Instruction Manual, it offers a comprehensive maintenance and
repair system. Refer to the ACAM Instruction Manual for detailed explanations of
"Solutions" listed in the ACAM Trouble Shooting Guide.
Through the ACAM Troubleshooting Guide, you will see "Reference" listed. Refer to
the inside back page for detailed address and phone number information for IDEAL
Technical Services / Engineering Applications Service, Customer Service, Quality
Hotline and your OEM Sales Specialists.
Quick Guide
I. General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pages 1 to 4
Connector won't tighten completely
Connector won't tighten at all
Finished connection doesn't have twists
Stripped wire twists off
Stripped wire is exposed
ACAM won't turn on
Electronic board will not function
Hand tool stops before completing connection
Connector is backward
Connector falls out of hand tool
Connector is jammed
II. Feed System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pages 4 to 7
Connector jammed in bowl
Connectors spilling out of bowl
Bowl will not stop vibrating
Vibration of bowl is inconsistent
Wire connector does not reach hand tool
III. Wire Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pages 7 and 8
Connector has no spring
Connector separates from spring
IV. Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 9
Connector won't tighten completely
V. Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . .Back cover page
Automatic Connector Application Machine
Optional Accessories
General Trouble Shooting Guide
Situation
If the wire connector won't tighten completely...
Possible Cause: Solution:
Torque adjustment too low. Check torque range (high vs. low)
and adjust torque level upward by
increments of 5 until connector
tightens correctly.
Gun is out of adjustment Adjust hand tool. Check to see if
finger receiving washer is correctly
positioned as hand tool is adjusted.
Incorrect strip length of wires Check with IDEAL for recommended
strip length. (Reference #1.
Situation:
If the wire connector won't tighten at all...
Possible Cause: Solution:
Hand tool is out of adjustment Adjust hand tool.
Disassembled, damaged or Repair or replace as needed.
broken drive shaft Check set-screws making drive shaft
connections.
Using wrong connector for machine Check machine number to connector
used. Reference #1.
Incorrect strip length of wires or Check with IDEAL for recommended
incorrect connector for strip length wire and wire connector
combinations for your specific wire size, insulation
and combinations. Reference #1.
Hand tool friction is set too low Increase hand tool friction setting on
keypad up to a maximum of 250.