HQST M4860N Manuel utilisateur

SKU: HCC60HTR-PL-US/CA
尺寸:105X142 MM
形式:骑马钉 共 24 页
材质:铜版纸128G

60A MPPT
CHARGE CONTROLLER
Model: M4860N SKU: HCC60HTR-PL-US/CA
- 1 -- 24 -
The user manual is meant to offer you a brief walkthrough of the
device’s features.
Please save the user manual for future reference.
Still need help? Please contact us via sales@myhqsolar.com
hqsolarpower.com
Download ChargePro app in Apple Store / Google Play Store
User Guide

- 2 - - 3 -
WARNINGS AND TOOLS ICON CHART SAFETY TIPS
Icons Name Description
High Voltage
High voltage device.
Installation should be performed by an
electrician.
High
Temperature
This device will produce heat.
Mount device away from other items.
Environmental
Hazard
Electronic Equipment.
Do not put in landfill.
Wire Cutter A wire cutter is needed for cutting and
stripping wires prior to connection.
Multi-meter A multimeter is needed for testing equipment
and verifying polarity of cables.
Anti-static
Glove
Anti-static gloves are recommended to prevent
controller damage caused by static electricity.
Electrical
Tape
Electrical tape is recommended to
safely insulate spliced or bare wires.
Screwdriver A common size screwdriver is needed
to attach wires to the controller.
Review this manual thoroughly before attempting installation.
Beware of any nearby electrical equipment that may interfere with
installing this device.
Solar panels can generate high voltages and currents, make sure your
solar panels are completely covered from sunlight during installation. It is
recommended that installation be performed by a quali fied electrician.
Connecting wires to this device can generate sparks, please wear proper
insulation gear while installing this device.
Always keep children away from this device.
Be certain to use the correct gauge of wire, see below for a table of
recommended wire size for various current loads.
To avoid damage to the battery or controller, use proper fuses in wiring.
Please do not hesitate to contact the professionals if you need help with
fuse sizing.
5A 10A 20A 30A 40A
1.5 2.5 5 8 10
15 13 10 8 7
60A
12
6
Solar Input Current
Wire Cross Section Area (mm²)
Wire AWG

- 4 - - 5 -
1 LCD Display Screen
Function Key ([SET], [UP], [DOWN], [ESC])2
3 External Temperature Sensor Terminal
Solar Terminals4
5 Battery Terminals
DC Load Terminals6
7 RS485 Communication Port
LED Indicator (PV, BAT, LOAD, FAULT)8
9 Installation Mounting Holes
PRODUCT FEATURES
DEVICE DIAGRAM
Thank you for choosing our products. This MPPT solar charge controller is a
device for solar charge regulation and direct current output load control. This
device is mainly used in small and medium sized off-grid solar power
systems.
By continuously checking solar panel power output changes, the control-
lers employ multiple MPPT charge algorithms in combination to boost
charging efficiency in different weather and temperature conditions.
Built-in buffer, allows max 25% exceeding rated power input.
Charging modes available for most common deep-cycle battery types in
the market, including AGM (sealed lead acid batteries), GEL, Flooded, and
Lithium.
Provides multiple load control mode options for light based, time based and
manually adjusted scenarios. Low no-load loss.
Industrial grade design with reverse polarity protection for solar panels,
battery and load.
Built-in BT communication module for operation on mobile phone APP. For
extending BT transmission distance, you can also connect external BT
module (optional, not included in the package).
Auto recognition of 12V/24V/36V/48V battery system voltage. Lithium
battery excluded from this feature.
Supports recording of system running data including power generated and
power utilized for up to 300 days, compatible with monitoring App through
IOS and Android.
We have built-in BT communication module in this controller and we
provide APP ChargePro for mobile phone monitoring and operation. You
can search “ChargePro” and download the APP at IOS APP Store and
Google Play Store.
These MPPT charge controllers have features as follows:
Description#
1
28
9
3 4 5 6 7

- 6 - - 7 -
φ 10
φ 5
Step 1
Find a cool, dry and weather
safe location for installation.
Step 3
Drill holes in the marked
mountiong hole location.
Step 5
Fasten the controller into the
pilot screws.
Step 6
Continue to wire battery. solar DC
load and other accessories to the
controller
Step 4
Insert pilot screws in the mounting
holes.
Step 2
Mark the controller's mounting
holes on the mounting surface.
Temperature Sensor
Connect the positive battery wire followed by the negative battery wire.1.
Make sure your solar panels are fully covered to prevent electrical shock.2.
Connect DC load wires to the DC load output (if applicable).4.
Connect the external temperature sensor to its terminal shown above, and
attach or stick the temperature sensor to the battery side.
5.
Connect the positive solar array output wire followed by the negative solar
array output wire.
3.
Download APP ChargePro and turn on the BT function in the mobile
phone. Testing the APP function with the controller.
6.
MOUNTING INSTRUCTION WIRE CONNECTION SEQUENCE
During installation of the controller, please follow the order of connection
below:

- 8 - - 9 -
Google Play and the Google Play logo are
trademarks of Google LLC
(Android)
LED Name LED Display Signal Indication
PV
BATTERY
Flash
Steady On
Flash
Steady On
Detected PV Error-Check Error code
In the Charging
Detected Battery Error-Check Error code
Battery On
Solar Input Not Charging
*PV LED is generally off during nighttime.
Check the Fault light to spot if a system error may be present.
LOAD
FAULT
Off
Off
Flash
Steady On
Load Off
Detected Load Error-Check Error code
DC Load On
Off
Steady On
No Errors
System Error – Check Error Code
LED LIGHT SIGNAL INTERPRETATION CHART
Connecting to the ChargePro app
(iOS/iPadOS)
Connecting to the ChargePro app
(Android)
Download the ChargePro app (iOS/iPadOS) to set up your charge
controller and monitor real-time data for enhanced charging experience.
Download the ChargePro app (Android) to set up your charge
controller and monitor real-time data for enhanced charging experience.
Apple and the Apple logo are
registered trademarks of Apple Inc
(iOS/iPadOS)

- 10 - - 11 -
Flash Status Indication Description
on
off
on
off
on
off
Steady On LED light on.
Off LED light off.
Fast Flash LED light blinks at frequency of
2Hz (twice every second).
RS485 PIN (RJ12)
Charge
Status
Active Functions
*Support 3.3 V,20mA
PIN-1
VDD
PIN-2
VDD
PIN-3
GND
PIN-4
GND
PIN-5
D-
PIN-6
D+
Display
Unit
Charge Status
Charge Mode
& Parameter
Active Functions
Display Section Display Layout
RS485 COMMUNICATION PORT
LCD DISPLAY INTERFACE
LCD DISPLAY INTERFACE OVERVIEW
LED FLASH RHYTHM CHART

- 12 - - 13 -
Solar Charge
Indication
Solar Power Charging Battery
Solar Power Not Charging Battery
DC Load
Indication
Charge Mode
Flowing
Steady
On
DC Load Drawing Power
DC Load Off
MPPT Charge Mode
Boost Charge Mode
Float Charge Mode
Not Charging
Flowing
Status Icon Indication Status Description
Voltage
Setting
Setting Charge Voltage
Charge Voltage Has Been Set
On
Solar Icon
Daylight Detected
No Daylight Detected
Solar System Over Voltage
Steady On
Over Discharge
Volt Settings
Flash
Setting Charge Voltage
Charge Voltage Has Been Set
Battery Icon
Battery Connected and Functional
No Battery Connection
Battery Over-Discharged
Steady On
Off
Off
Flash
Load Status
DC Load Short Circuit or Over-Load
Load On
Load Off
Flash
ON
OFF
On
Off
Off
Off
Off
Off
Function Key System Mode Input Input Function
Function Key System Mode Input Input Function
View Mode
View Mode
View Mode
View Mode
Long Press
Short Press
Short Press
Short Press
Enter SET mode
View Previous Page
View Next Page
DC Load On/Off
(Manual Control Program Only)
Set Mode
Set Mode
Set Mode
Short Press
Short Press
Short Press
Increase Parameter Value
Decrease Parameter Value
Exit SET Mode Without
Saving
Save Data & Exit SET Mode
Next Setting
Long Press
Short Press
Set Mode
KEY FUNCTIONALITY CHART
LCD STATUS INFORMATION

- 14 - - 15 -
Setting Battery Mode
LCD Screen Display Cycle
Pre start-up display cycle when the MPPT controller turns on, this usually last
several seconds while controller detects operating environment.
Charging PV Voltage Charging Amperage
Charging
Watt-hour
Controller
Temperature
Load ModeLoad Watt-hour Load Amperage
Battery Voltage
Battery Capacity
(Only for reference)
Error Code
Default Page
The battery voltage view will be displayed by default. Use the up and down
arrow keys to cycle through different views. The battery voltage view will
resume upon 30 seconds of inactivity. The error code view will be displayed
when an error is detected. The backlight in the screen will be on for 20
seconds with any button operation.
Abbreviations Battery Types Description
FLD
SEL
GEL
LI
USE
Flooded Battery
Sealed/AGM Battery
Gel Battery
Lithium Battery
Advanced User Mode
Auto-recognition with default
parameters set for each type of
batteries.
Low temperature protection (
Frozen charge forbid). Some
parameters can be customized.
Most parameters can be
customized.
LCD DISPLAY RULES & CYCLES
Enter SET mode by pressing the Setting key in any view page other than
Load Mode Or Controller Temperature. Use the up and down arrow keys to
select battery mode, then long press Setting key to save.

- 16 - - 17 -
Enter Load SET Mode by pressing the Setting key in Load Mode view only.
Use the arrow key to cycle through load modes before long pressing SET to
save and exit. Short pressing ESC will exit without saving.
In the temperature display interface, enter the temperature unit setting mode
by long pressing the setting button. You can switch between ℉(Fahrenheit)
and ℃(Celsius) by pressing up and down arrow key. Long press the setting
button to confirm saving and exit, and short press the ESC key to exit the
setting without saving.
Load Mode Settings
Load Mode View Setting Load Mode
Long [ SET ] press
save and exit setup
short [ESC]press
exit without saving
[ SET ]
Temperature Unit Setting
Advanced Battery Settings
Pressing the Setting key to enter SET mode.Choose Lithium or User mode,
short press the Setting key again to cycle through each parameter view.
Use the up and down arrow key to adjust parameter value, then long press
Setting key to save.
For Battery Type: Li
Low Temperature Proctection(Frozen Charge Forbid)
Battery Type: USER System Voltage Equalize Charge Voltage Boost Charge Voltage
Float Charge VoltageEqualize Charge Interval
Over-discharge Recovery
Over-discharge Voltage
Battery Type: Li System Voltage Charge Voltage
Over-discharge Voltage Over-discharge Recovery
Frozen Charge Forbid = OFF
Frozen Discharge Forbid Range = 5±9℉/-15±5℃
When the temperature reaches the protected
on/off range, the low-temperature protection will
automatically turn on/off after 30 seconds.
Frozen Charge Forbid Range = 32±9℉/0±5℃
For Battery Type: USER
ON
Frozen Forbid = ON
Mode Definition Description
0
1~14
15
16
Daylight Auto-Control
Daylight On/Timer Off
Manual Mode
Testing Mode
DC load turns on when no daylight is detected.
DC load turns on when no daylight is detected.
DC load turns off according to timer.
DC load turns on/off by pressing the Return key.
DC load turns on and off in a quick succession.
DC load stays on.
Always On17