HOME ALARM 4099 Manuel utilisateur

1

2
BEFORE INSTALLING AND USING THIS SYSTEM, YOU ARE STRONGLY
RECOMMENDED TO READ THIS MANUAL CAREFULLY.
一、 BEFORE USING THE SYSTEM:
1. Make sure all the arming zones are working normally.
2. Avoid heavy impacts and unnecessary disassembly which might incurs accident or man-made
damage.
3. When installing, avoid touching the electronics components which on the PCB with hand or metal
parts.
4. When installing, make sure the AC power supply is stable (if the AC power supply is cut, the system
will shift to backup battery automatically).
5. The unit has alarm priority function. Make sure main unit is connected with telephone line so that it can
automatically dial the presented phone number.
6. Make sure you have charged the system for at least 12 hours uninterruptedly before using the system
for the first time.
7. Low voltage of the batteries in the main unit may cause constant beeps from main unit or subnormal
display on the LCD.
二、Main features and functions
(1)Built-in 16 wireless defense zones and 8 wired defensive zone microcomputer control
(2)Keyboard operation ,English LCD display for menu
(3)Latest American CPU processing circuit.
(4) CPU code
(5) CMS optional ,support Ademco Contact ID.

3
(6) Independent defense zone setting
(7) Multi-way to arm and disarm (by remote controller, keyboard ,regular,mobilephone)
(8) 36 event log that easily be managed the alarming scene
(9) listen to the record and monitor the alarming scene using mobile phone when receiving phone
calls.
(10) Door lock systems controlled by ID card
(11) Panic alarm
(12) Built-in 85 db siren
(13) Alarm time display
(14) 12v power supply outlet for wired accessories
(15) alarming zones alert with sound
三、Main parts name and instruction(see Picture 1)
(一)Built in DIP switch(Picture 1):
Picture 1

4
N
o.
Position
Pin switch
ON OFF
1
Remote
control switch
Enable (DEFAULT)
Disable
2
Password
Reset switch
Reset system
If you forgot password, you can put this DIP to
ON, then turn off the power, then turn on the
power again, the system’
s password will return to
“000000”. After resetting the system, remember to
put the DIP back to OFF position
Normal (DEFAULT)
3
CMS format
Switch
AOLIN format(DEFAULT) Ademco Contact ID
format
4
CMS
connection
Switch
Dial the phone number of CMS Not dial the phone
number of
CMS(DEFAULT)
(2). front(Picture 3)

5
(Picture 2)
(1) power supply indicator( red): Permanently on when turning on the control panel
(2) arm/disarm indicator(red) –arm : Permanently on when under status of arming, off when the
unit is disarmed.
(3)AC fault indicator (red): Permanently on AC power supply is off AC.
(4)LCD display : display for menu and alarm event log
(5) keyboard: for operation and card reading
(三)side(Picture 3)

6
(Picture 3)
(1) Antenna: Pull out the antenna when operating the unit for better signal receiving.
(2)Microphone: For monitor the alarming scene through Mobilephone.
(四)ARCHITECTURE OF THE CONTROL PANEL(Picture 4)
(Picture 4)
(1) Telephone port: AC:18V input,For connection of power transformer(connected)
Phone In: for connection of the main phone line

7
(Notice:If the system shares a same phone line with your daily-used telephone ,make sure the main
phone line goes in the system first, then you can connect yours telephone to the PHONE OUT
connector. This is to eliminate the possibility of faiture in the telephone which might block the
system to get in touch with you when there is a alarming)
(2) 12V DC:For connection of wired accessories
(3) SPK:For 12V/1A external speaker
LED:For showing the working status of the unit (notice:a current around 4.7k resistor is needed to
be in series connection with the LED lamp)
E.L.:Interface for electronic lock of door entry system. External power supply is needed.
BLU RED:For keypad ,BLU for black,RED for red
YEL GRN:For keypad or other accessories of BUS,YEL for yellow,GRE for green
1—-8 wired zone :for wired protective zones, Each interface needs one 2.2K resistor be connected.
(Zone 1 is for smoke/gas detectors, this zone is always in armed status for safety reason)
四、menu and operation
1. remote controller(Picture 5)
Arm : press the button once, the mainframe will give a short
“Bi” once to enter audio alarm status; press the button again, the
mainframe will sound “BI-BI” twice ,then the system will enter
mute alarm status.
Disarm : when the control panel is alarming, press the button
to stop it.
Panic : No matter what status is the control panel, press this
button once the control panel will alarm immediately.
Stay : Press the button to alter arm or disarm status for different
zones .
Quick entry + , the control panel enters arm status without
any delay.

8
(Picture 6)
(5)Keypad (picture 6)
1、KEY
A.
* : cancel the present operation and go to the previous menu.
# : confirm the present operation and go to the next menu
ARM:
(1) As cursor key under status of setting or as the backspace key when editing.
(2) Press the button once, the mainframe will give a short “Bi” once to enter audio alarm status.
STAY:Press the button to enter the presetted particially alarm .
PANIC:No matter what status is the control panel , Quick press this button 3 times, the control panel will
alarm immediately and dial the preset phone number.
MUTE:(1)。As cursor key under status of setting
(2). press the button, the control panel will sound “BI-BI” twice ,then the system will enter mute alarm
status.
B. quick arming via keyboard (3 ways):
①:keep pressing * for 3 second until hearing a short sound under disarming status, the control
panel enter 8 wired and 8 wireless defense zone(from left to right),then press “ 0” to turn off the
defense zone that cursor key locates, press “1” to turn on the defense zone that the cursor key

9
locates , the control panel enter the arming status if pressing “#”.(the control panel will never store
the setting for next time using this way )
②:”arm” for turning on all audio defense zone and “mute” for turning on all mute defense
zone (the control panel has memory function if using the way for setting)
③:”stay” for particail defenses zone setting (the control panel has memory function if using
the way for setting)
C.quick disarming via keyboard
Press “#” and insert code, then press “#“ under arming status
3. System settings & functions
(1) Enter system setting
Make sure the control panel is in disarmed status, then enter the MENU (default setting is disarmed).If
the system is in armed status, you need to enter the disarming password (default 000000),then press “#
“ to confirm to enter the system setting status, The control panel will sound BIBI and the programming
indicator is on if the password is correct .The control panel will sound BIBIBI if the password is not
correct.
(2) Exit system setting
Under the status of setting ( not under the subtitle status), press “ # # “ to exit ,programming indicator
is off.
The system will exit automatically if you have no operation with 20 seconds
(1).Modify the default password
max. length of the password is 6 numbers
(2).Modify the system display time
after enter new time, press “#” to confirm.
(3).Telephone setting
“Menu” – “telephone setting” ,input the 1st telephone number and press “#” to confirm,
press “ arm ” or “ mute ” to select the “ telephone 2 ” ,then input the 2nd telephone

10
number ,repeat the process to set the 3rd telephone, press “arm” to modify the input
number.
(4).CMS
The system can be connected with centre monitoring station ,CMS telephone number and
user’s code is needed.
(5).Record and record playback
Record is for recording message that can be heard when receiving alarm call from the control
panel, the max. length of the record is 20 sec.
Playback is for testing the record contents from the control panel.
4.2 advantage menu
4.2.1 code learning
4.2.1.1 remote controller
Each remote controller can be set freely to control the wish defense zone.
Select “code learning for remote controller” ,press “#”,the LCD displays “code is learning”,press
any button on the remote controller for 3 seconds .The code learning is successful when you
hear ”DIDI”, The LCD displays interface of defense zone setting, all defense zones are selected
in original, the cancel or select the defense zone by using button ”arm”, ”mute”, 0”, ”1”, press “#”
to confirm the setting and then set the next remote controller, press “*” to exit after all the remote
controllers have been set .
Remark: Max. 10 remote controllers can be learnt.
4.2.1.2 detector
select “code learning for detector”and press ”#” ,the LCD displays “please input defense zone
Table des matières
Manuels Système de sécurité populaires d'autres marques

EDM
EDM Solution 6+6 Wireless-AE Manuel utilisateur

Highway Safety Group
Highway Safety Group EA401 Manuel utilisateur

Siren
Siren LED GSM Manuel utilisateur

Detection Systems
Detection Systems 7090i Instructions de montage

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuel utilisateur

Siemens
Siemens FDM273 Manuel utilisateur