Homelift2 user guide Version 01/2012
R
RE
EC
CO
OM
MM
ME
EN
ND
DE
ED
D
C
CH
HE
EC
CK
KS
S
Item to check check
Periodicity : at least once a year and before renting it.
* Replacement after
10 000 cycles
1 Beam support / beam
axis connection
- Check stop-nut presence and assembling
- Check fixing screw worn state
- Check fixing metal tongue welding
2 Beam axle - Check axle worn state
- Check bottom fixing screw + ring worn state
3 Beam hooks - Check fixing points of the 4 hooks
- Check welding points worn state
4 Strap - Check seams
5 Actuator - Check charging operating
6 Emergency release
- Check electrical and manual release operating
7 Control box
- Check emergency stop operating
- Check battery charging
8 Electrical cables
- Check cables (pinching, plug state, cut …)
9 Actuator / beam
support connection
- Check fixing screw worn state
- Check stop-nut presence and assembling
10 Pole / beam support
connection
- Check brass ring worn state
- Check fixing screw worn state
- Check stop-nut presence and assembling
11 Actuator / pole
connection
- Check fixing screw worn state
- Check stop-nut presence and assembling
12 Pedals - Check pedals operating
- Check connecting rods worn state
13 Back wheels - Check braking system
14 Side foot / cross piece
connection
- Check fixing worn state (screw nut + brass rings)
15 Pole / cross piece
connection
- Check knobs presence and assembling
- Check pole welding
*See table on page 12 to list necessary spare parts
Hoists are conformed to EN 10535 standard which means that they can run 10 000 complete cycles under
the conditions of uses they are designed for. Please, carefully consider how important it is to evenly check
and maintain it in order to make sure that it is used under the standard specifications and under ours
recommendations. We will not be responsible for any damage due to an abnormal use or to a too high
number of cycles. You will find all the information you need for your checking and maintenance steps on
pages 9, 10, 11 and 12.