Hioki SS7012 Manuel utilisateur

i
Contents
Introduction .......................................................................... 1
Confirming Package Contents ............................................. 2
Safety Information ................................................................ 3
Operating Precautions ......................................................... 7
Chapter 1 Overview 13
1.1 Product Overview .............................................. 13
1.2 Features ............................................................ 14
1.3 Names and Functions of Parts .......................... 15
1.4 Sourcing and Measurement Flowchart ............. 23
Chapter 2 Sourcing, Measurement and
Loop test Preparation 25
2.1 Supplying Power ............................................... 25
Installing or Replacing the Batteries .................. 25
Connecting the AC Adapter (Option) ................ 27
2.2 Connecting the Input Cord and the Test Lead .. 28
2.3 Turning the Power On and Off .......................... 33
2.4 Pre-Operation Inspection .................................. 34
Chapter 3 Sourcing 37
3.1 Sourcing Example ............................................. 38
3.2 Sourcing Constant Voltage and
Constant Current ............................................... 39
3.3 Sourcing Thermoelectromotive Force ............... 43
3.4 0°C Check of the
100 Ω Resistance Thermometer ....................... 50
3.5 Output Monitor Function .................................... 51
3.6 Memory Source Function .................................. 54
Saving setting value to memory ........................ 55
Recall sourcing .................................................. 59
SS7012A981-08

ii
Scan sourcing ....................................................61
Initializing setting values ....................................63
3.7 When setting value is flashing ...........................65
Chapter 4 Measurement 67
4.1 Measurement Example ......................................67
4.2 Voltage Measurement and
Current Measurement ........................................68
4.3 Temperature Measurement ...............................71
Chapter 5 Loop Test 75
5.1 Loop Test Overview ...........................................75
5.2 Testing a Distributor (4-20 mA) .........................76
5.3 Testing a two-wire transmitter ...........................79
Chapter 6 Other Function 81
6.1 USB Communication Function ..........................81
Chapter 7 Specifications 83
7.1 General Specifications .......................................83
7.2 Accuracy ............................................................86
Chapter 8 Maintenance and Service 91
8.1 Troubleshooting .................................................91
8.2 Replacing the Circuit Protection Fuse ...............94
8.3 Cleaning ............................................................96
8.4 Error Indication ..................................................97
8.5 Other Indication .................................................97
8.6 When calibrating the instrument ........................98
Index Index 1

Introduction 1
Thank you for purchasing the HIOKI Model SS7012 DC Signal
Source. To obtain maximum performance from the instrument,
please read this manual first, and keep it handy for future refer-
ence.
Introduction

Confirming Package Contents
2
When you receive the instrument, inspect it carefully to ensure
that no damage occurred during shipping. In particular, check
the accessories, panel switches, and connectors. If damage is
evident, or if it fails to operate according to the specifications,
contact your dealer or Hioki representative.
Confirming Package Contents
Confirm that these contents are provided.
SS7012 DC Signal Source (1)
Instruction Manual (1)
9168 Input Cord (1 set)
LR6 alkaline batteries (4)
L9170-10 Test lead (1 set)
Spare fuse (1)

Safety Information 3
Options
9184 Temperature Probe (reference junction compensation)
9380 Carrying Case (Holds main unit only, soft case)
9782 Carrying Case (Holds options, hard case)
9445-02 AC Adapter (For Japan, US, and Canada)
9445-03 AC Adapter (For EU)
SS9000 Communication Package
(Includes USB cable and USB driver software)
Safety Information
This instrument is designed to comply with IEC 61010
Safety Standards, and has been thoroughly tested for
safety prior to shipment. However, mishandling during use
could result in injury or death, as well as damage to the
instrument. Using the instrument in a way not described in
this manual may negate the provided safety features.
Be certain that you understand the instructions and pre-
cautions in the manual before use. We disclaim any
responsibility for accidents or injuries not resulting directly
from instrument defects.

Safety Information
4
This manual contains information and warnings essential for
safe operation of the instrument and for maintaining it in safe
operating condition. Before using it, be sure to carefully read the
following safety precautions.
The following symbols in this manual indicate the relative impor-
tance of cautions and warnings.
Safety Symbols
In the manual, the symbol indicates particularly
important information that the user should read
before using the instrument.
The symbol printed on the instrument indicates
that the user should refer to a corresponding topic in
the manual (marked with the symbol) before
using the relevant function.
Indicates a grounding terminal.
Indicates DC (Direct Current).
Indicates the ON side of the power switch.
Indicates the OFF side of the power switch.
Indicates that incorrect operation presents
an extreme hazard that could result in seri-
ous injury or death to the user.
Indicates that incorrect operation presents a
significant hazard that could result in serious
injury or death to the user.
Indicates that incorrect operation presents a
possibility of injury to the user or damage to
the instrument.
Indicates advisory items related to perfor-
mance or correct operation of the instru-
ment.

Safety Information 5
Symbols for Various Standards
WEEE marking:
This symbol indicates that the electrical and
electronic appliance is put on the EU market
after August 13, 2005, and producers of the
Member States are required to display it on the
appliance under Article 11.2 of Directive 2002/
96/EC (WEEE).
Ni-MH
This is a recycle mark established under the
Resource Recycling Promotion Law (only for
Japan).
This symbol indicates that the product conforms
to regulations set out by the EC Directive.
Other Symbols
Indicates a prohibited action.
(p. #) Indicates the location of reference information.
[ ] The names of setting objects are indicated by
square brackets [ ].
OUTPUT
(Bold char-
acters)
Bold alphanumeric characters in this manual indi-
cate key labels.
The screen of this instrument displays characters in the follow-
ing manner.

Safety Information
6
To ensure safe operation of measurement instruments IEC
61010 establishes safety standards for various electrical envi-
ronments, categorized as CAT II to CAT IV, and called measure-
ment categories.
Using a measurement instrument in an environment designated
with a higher-numbered category than that for which the instru-
ment is rated could result in a severe accident, and must be
carefully avoided.
Use of a measurement instrument that is not CAT-rated in CAT II
to CAT IV measurement applications could result in a severe
accident, and must be carefully avoided.
Measurement categories
CAT II
Primary electrical circuits in equipment connected to an AC
electrical outlet by a power cord (portable tools, household
appliances, etc.)
CAT II covers directly measuring electrical outlet recepta-
cles.
CAT III
Primary electrical circuits of heavy equipment (fixed instal-
lations) connected directly to the distribution panel, and
feeders from the distribution panel to outlets.
CAT IV
The circuit from the service drop to the service entrance,
and to the power meter and primary overcurrent protection
device (distribution panel).

Operating Precautions 7
Follow these precautions to ensure safe operation and to obtain
the full benefits of the various functions.
Before using the instrument for the first time, verify that it oper-
ates normally to ensure that no damage occurred during storage
or shipping. If you find any damage, contact your dealer or Hioki
representative.
Operating temperature and humidity: 0 to 40°C at 80%RH or
less (non-condensating)
Temperature and humidity range for guaranteed accuracy:
23±5°C, 80%RH or less (non-condensating)
Operating Precautions
Preliminary Checks
Instrument Installation
Avoid the following locations that could cause an accident or damage
to the instrument.
Exposed to direct
sunlight
Exposed to high tem-
perature
In the presence of cor-
rosive or explosive
gases
Exposed to liquids
Exposed to high hu-
midity or condensa-
tion
Exposed to strong
electromagnetic fields
Near electromagnetic
radiators
Exposed to high lev-
els of particulate dust
Near electromagnetic
radiators (e.g., high-
frequency induction
heating systems and
IH cooking utensils)
Subject to vibration
Correct measurement may be impossible in the pres-
ence of strong magnetic fields, such as near transform-
ers and high-current conductors, or in the presence of
strong electromagnetic fields such as near radio trans-
mitters.