Hillphoenix ONRB Manuel du propriétaire

HANDBOOK
INSTALLATION & OPERATION
REACH-IN
BEVERAGE
CASES
P057333G
Rev. 12 6/06
MODEL: ORB, ORBH,
ONRB & ONRBH
COMPONENT


Welcome to the ORIGIN2display case family. We’re very pleased you
joined us.
This installation and operation handbook has been especially
prepared for everyone involved with ORIGIN2display cases – owners,
managers, installers and maintenance personnel.
You’ll find this book different than traditional manuals. The most
dramatic difference is the use of many more illustrated instructions to
make it easier to read and to help you get the most from this innovative
new design. When you follow the instructions you should expect
remarkable performance, attractive fits and finish, and long case life.
We are interested in your suggestions for improvement both in case
design and in this handbook. Please call/write to:
Hill PHOENIX
Marketing Services Department
1925 Ruffin Mill Rd.
Colonial Heights, VA 23834
Tel: 804-526-4455
Fax: 804-526-7450
or visit our web site at
www.hillphoenix.com
We wish you the very best in outstanding food merchandising and a
long trouble-free operation.


1
TABLE OF CONTENTS
GENERAL INFORMATION – PAGES 3 - 8
General information, first step recommendations and case dimensional drawings.
THE USE OF CASTERS – PAGE 9
Cases roll on casters–general use and caster removal.
LINE-UP – PAGES 10 - 11
A twelve step procedure for initial case lineup with illustrations.
TRIM-OUT – PAGES 12 - 13
A fifteen step procedure for trimming out cases with illustrations.
REFRIGERATION PIPING – PAGE 14
Diagrams show coil outlet, case controls location, and other piping tips.
PLUMBING – PAGE 15
Information on drain connections.
ELECTRICAL HOOKUP AND WIRING DIAGRAMS – PAGES 16 - 25
Complete information on electrical connections.
CONTROL SETTING GUIDELINE – PAGES 26 - 29
Recommended settings for all case controls.
DEFROST AND TEMPERATURE CONTROL – PAGE 30
Defrost data - electric and hot gas defrost. Sensor bulb locations.
PRODUCT LOADING – PAGE 31
Air flow and load limits.
USE AND MAINTENANCE – PAGES 32 - 33
Cleaning and fan information.
PARTS ORDERING – PAGES 34 - 36
Replacement parts identification.
APPENDIX A - PAGE 37
NOTES - PAGE 38
PRODUCT WARRANTY - Inside Back Cover

2

3
GENERAL INFORMATION
DESCRIPTION OF CASES: The refrigerated display cases described in this handbook
are part of the Hill PHOENIX, Origin2design series. Specifically covered in this manual are
models ORB reach-in beverage, ORBH high reach-in beverage, ONRB narrow reach-in bev-
erage, & ONRBH high narrow reach-in beverage.
STORE CONDITIONS: Hill PHOENIX cases are designed to operate in an air conditioned
store with a system that can maintain 75OF (24OC) store temperature and 55 percent (maxi-
mum) relative humidity (CRMA conditions). Case operation will be adversely affected by
exposure to excessively high ambient temperatures and/or humidity.
REFRIGERATION SYSTEM OPERATION: Air cooled condensing units require ventilation for
efficient performance of condensers. Machine room temperatures must be a minimum of
65OF in winter and a maximum of 95OF in summer. Minimum condensing temperatures
should be no less than 70OF.
RECEIVING CASES: Examine fixtures carefully for shipping damage and shortages. For
information on shortages contact the Service Parts Department at 1-800-283-1109.
APPARENT DAMAGE: A claim for obvious damage must be noted on the freight bill or
express receipt and signed by the carriers agent, otherwise the carrier may refuse the claim.
CONCEALED DAMAGE: If damage is not apparent until after the equipment is unpacked,
retain all packing materials and submit a written request to the carrier for inspection within
15 days of receipt of equipment.
LOST ITEMS: This equipment has been carefully inspected to insure the highest level of
quality. Any claim for lost items must be made to Hill PHOENIX within 48 hours of receipt
of equipment.
TECHNICAL SUPPORT: If any technical questions arise regarding a refrigerated display
case contact our Customer Service Department in Richmond at 1-804-526-4455. For any
questions regarding our refrigeration systems or electrical distribution centers contact our
Customer Service Department in Conyers at 1-770-285-3200.
CONTACTING FACTORY: Should you need to contact Hill PHOENIX regarding a specific
fixture, be sure to know the case model number and serial number. This information is on
the serial plate located on the top flue panel of the case (see next page for details). Ask for
a Service Parts Representative at 1-804-526-4455.

4
41 7/16 in [105.2 cm]
81 1/4 in
[206.3 cm]
83 1/4 in
[211.5 cm]
6 13/16 in [17.2 cm]*
42 11/16 in [108.4 cm]
COIL PLENUM
30 7/8 in [78.4 cm]
59 in
[149.9 cm] 62 3/8 in
[158.4 cm]
(Door Height)
64 in
[162.6 cm]
(Frame Height)
C
L
34 11/16 in
[88.1 cm]
31 9/16 in
[80.2 cm]
10 in
[25.4 cm]
JUNCTION BOX
(STANDARD)
8 in [20.3 cm] WIRING-TO-TOP
(OPTIONAL)
35 1/8 in
[89.2 cm]
**
1 1/2" PVC DRAIN
CONNECTION
28 5/8 in
[72.7 cm]
33 9/16 in
[85.3 cm]
39 1/4 in
[99.7 cm]
REFRIGERATION
1 1/2 in
[3.8 cm]
{END}
8 11/16 in [22.1 cm]
FRONT OF CASE
5 1/8 in
[13.1 cm]
16 1/16 in
[40.9 cm]
8 1/2 in
[21.6 cm]
31 9/16 in [80.2 cm]
39 1/4 in [99.7 cm]
NOTES:
* STUB-UP AREA
** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS
zENDS ADD APPROXIMATELY 1 INCHTO CASE HEIGHT
zWIRING-TO-THE-TOP- ADDS APPROXIMATELY 1 INCHTO CASE HEIGHT
zA 2" MINIMUM AIR GAP IS REQUIRED BETWEENTHE REAR OFTHE CASE AND AWALL
zSUCTION LINE (ALL LENGTHS) 1/2"
zLIQUID LINE (ALL LENGTHS) - 3/8", LIQUID LINE w/ HOT GAS DEFROST (ALL LENGTHS) - 1/2"
zAVAILABLE SHELF SIZES: WIRE SHELVES 16", 18", 20", 22" & 23 1/2"
SOLID SHELVES 18", 20", 22", 24" & 27"
(TOP SHELF MUST BE 24" OR SHORTER WHEN USING 27" SHELVES.
RECOMMENDED CONFIGURATION IS 1 - 24" SHELF AND 4 - 27" SHELVES BELOW
TOP SHELF)
60 in [152.4 cm] {2 Door}
90 in [228.6 cm] {3 Door}
120 in [304.8 cm] {4 Door}
150 in [381.0 cm] {5 Door}
180 in [457.2 cm] {6 Door}
4 in [10.2 cm]
PIPING-TO-TOP
(OPTIONAL)
12 3/4 in [32.4 cm] 3 3/8 in [8.6 cm]
REAR REFRIGERATION
(13 15/16" off of floor)
42 11/16 in
[108.4 cm]
7 1/2 in
[19.1 cm]
1/2 BUMPER OPTION
ELECTRICAL
16 1/16 in [40.8 cm]
18 9/16 in [47.1 cm]
Amp plate &
Serial Plate
location
MODEL
ORB
GENERAL INFORMATION

5
NOTES:
* STUB-UP AREA
** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS
zENDS ADD APPROXIMATELY 1 INCHTO CASE HEIGHT
zWIRING-TO-THE-TOP- ADDS APPROXIMATELY 1 INCHTO CASE HEIGHT
zA 2" MINIMUM AIR GAP IS REQUIRED BETWEENTHE REAR OFTHE CASE AND A WALL
zSUCTION LINE (ALL LENGTHS) 1/2"
zLIQUID LINE (ALL LENGTHS) - 3/8", LIQUID LINE w/ HOT GAS DEFROST (ALL LENGTHS) - 1/2"
zAVAILABLE SHELF SIZES: WIRE SHELVES 16", 18", 20", 22" & 23 1/2"
SOLID SHELVES 18", 20", 22", 24" & 27"
(TOP SHELF MUST BE 24" OR SHORTER WHEN USING 27" SHELVES.
RECOMMENDED CONFIGURATION IS 1 - 24" SHELF AND 4 - 27" SHELVES BELOW
TOP SHELF)
7 1/2 in
[19.1 cm]
1/2 BUMPER OPTION
41 7/16 in [105.2 cm]
6 13/16 in [17.2 cm]*
42 11/16 in [108.4 cm]
COIL PLENUM
30 7/8 in [78.4 cm]
5 1/8 in
[13.1 cm]
16 1/16 in
[40.9 cm]
8 1/2 in
[21.6 cm]
31 9/16 in [80.2 cm]
39 1/4 in [99.7 cm]
85 1/16 in
[216.0 cm]
87 1/16 in
[221.1 cm]
63 in
[160.1 cm] 66 3/8 in
[168.6 cm]
(Door Height)
68 in
[172.7 cm]
(Frame Height)
C
L
34 11/16 in
[88.1 cm]
31 9/16 in
[80.2 cm]
10 in
[25.4 cm]
JUNCTION BOX
(STANDARD)
8 in [20.3 cm] WIRING-TO-TOP
(OPTIONAL)
35 1/8 in
[89.2 cm]
**
1 1/2" PVC DRAIN
CONNECTION
28 5/8 in
[72.7 cm]
33 9/16 in
[85.3 cm]
39 1/4 in
[99.7 cm]
REFRIGERATION
1 1/2 in
[3.8 cm]
{END}
8 11/16 in [22.1 cm]
FRONT OF CASE
4 in [10.2 cm]
PIPING-TO-TOP
(OPTIONAL)
12 3/4 in [32.4 cm] 3 3/8 in [8.6 cm]
REAR REFRIGERATION
(13 15/16" off of floor)
42 11/16 in
[108.4 cm]
60 in [152.4 cm] {2 Door}
90 in [228.6 cm] {3 Door}
120 in [304.8 cm] {4 Door}
150 in [381.0 cm] {5 Door}
180 in [457.2 cm] {6 Door}
96 in [243.8 cm] {8' case}
144 in [365.8 cm] {12' case}
ELECTRICAL
16 1/16 in [40.8 cm]
18 9/16 in [47.1 cm]
MODEL
ORBH
Amp plate &
Serial Plate
location

6
C
L
NOTES:
* STUB-UP AREA
** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS
zENDS ADD APPROXIMATELY 1 INCHTO CASE HEIGHT
zWIRING-TO-THE-TOP- ADDS APPROXIMATELY 1 INCHTO CASE HEIGHT
zA 2" MINIMUM AIR GAP IS REQUIRED BETWEENTHE REAR OFTHE CASE AND A WALL
zSUCTION LINE (ALL LENGTHS) 1/2"
zLIQUID LINE (ALL LENGTHS) - 3/8", LIQUID LINE w/ HOT GAS DEFROST (ALL LENGTHS) - 1/2"
zAVAILABLE SHELF SIZES: WIRE SHELVES 16", 18", 20" & 22"
SOLID SHELVES 18", 20" & 22"
(TOP SHELF MUST BE 20" OR SHORTER. RECOMMENDED CONFIGURATION IS 20"
SHELF AND 4 22" SHELVES BELOW TOP SHELF)
JUNCTION BOX
(STANDARD)
WIRING-TO-TOP
(OPTIONAL)
ELECTRICAL
1 1/2" PVC DRAIN
CONNECTION
REFRIGERATION
FRONT OF CASE
10 in
[25.4 cm]
8 in [20.3 cm]
16 1/16 in [40.8 cm]
18 9/16 in [47.1 cm]
27 9/16 in
[70.0 cm]
**
23 1/4 in
[59.1 cm]
26 7/8 in
[68.3 cm]
1 1/2 in [3.8 cm]
{END}
8 11/16 in [22.1 cm]
COIL PLENUM
23 1/4 in
[59.1 cm]
6 13/16 in [17.3 cm]*
24 3/16 in
[61.4 cm] 31 7/8 in
[81.0 cm]
35 3/8 in [89.8 cm]
5 1/8 in
[13.1 cm]
16 1/4 in
[41.3 cm]
8 in
[20.3 cm]
64 in
[162.6 cm]
(Frame Height)
62 3/8 in
[158.4 cm]
(Door Height)
59 in
[149.9 cm]
24 3/16 in [61.4 cm]
31 7/8 in [81.0 cm]
27 5/16 in
[69.4 cm]
REAR REFRIGERATION
(12 1/4" off of floor)
4 in
[10.2 cm]
PIPING-TO-TOP
(OPTIONAL)
3 3/8 in [8.6 cm]
12 3/4 in [32.4 cm]
60 in [152.4 cm] {2 Door}
90 in [228.6 cm] {3 Door}
120 in [304.8 cm] {4 Door}
150 in [381.0 cm] {5 Door}
81 1/4 in
[206.4 cm]
83 1/4 in
[211.5 cm]
34 5/8 in [88.0 cm]
7 1/2 in
[19.1 cm]
1/2 BUMPER OPTION
35 3/8 in
[89.8 cm]
MODEL
ONRB
Amp plate &
Serial Plate
location
GENERAL INFORMATION
Ce manuel convient aux modèles suivants
7