Operating intervals:
In order to avoid over heating of grindstones and grinding chamber (resulting unnecessary heating of the
coffee) the manufacturer is recommending using the appliance continuously for short intervals of a few
minutes each. Never exceed 10 minutes of continues grinding (or more than 1.5 kg of coffee beans).
Adjusting coffee grinding
The Titan grinders’ family (Titan I, II) are equipped with the revolutionary patented Bottom-Setting©®™
mechanism with LCD to read the grinding position accurately and constantly. The position of the grinding
setting knob and LCD are on the left side bottom part of the body (see fig. 5.2).
Fig 5.2
The grinding grindstones’ distance was factory pre adjusted to satisfy different common coffee grinds from
fine Turkish coffee powder to coarse filter brewing. This clearance span can be achieved by turning the
grinding setting knob for 12 full turns. Turning the grinding setting knob incrementally counterclockwise (CCW)
will make the grind coarser and turning it clockwise (CW) will make the grind finer. Practically we recommend
making grind changes by turning the knob ¼ turn at a time.
The coarseness setting and accordingly the LCD reading should be performed only when grinder is plugged
to power.
In course of normal usage (and especially if changing setting of the grinder while grinder is unplugged) there
might be a need to recalibrate the digital display to match the actual grinder’s setting
The digital system is including a self-homing (automatic reset). There are 2 possible cases for recalibration.
oCase 1: The display is showing a finer digit than the actual grinding
oCase 2: the display is showing coarser digit than the actual grinding
In both cases start the recalibration by empty the coffee beans from grinding chamber by closing the hopper’s
door and grinding till grind it is empty.
In both cases the recalibration is starting by setting the grinder to finest grinding coarseness by turning the
knob clockwise.
Case 1:
oWhile setting, note that the display will show ‘- - ‘ which is below 0.1, continue to turn the knob till it
cannot be turned any more. Then by turning back the knob counter clockwise the grinder already is
recalibrated and ready for use.
Case 2:
oWhile reaching the point where the knob cannot be turned any more and the display still showing a
number which is greater than ‘0.1‘
oDisconnect the power plug, turn the knob counterclockwise few turns (5-10),
oComplete the recalibration as in Case 1 above.
Test the recalibration by having the grinder plugged to the power, and make few turns coarser and back to
finer make sure that every time at most fine (where the knob cannot be turned any finer) the display is
showing ‘0.1’