Heta SCAN-LINE GREEN 250 Manuel utilisateur

1
OPERATING AND INSTALLATION
INSTRUCTIONS
DANISH DESIGN . DANISH QUALITY . DANISH PRODUCTION
www.heta.dk
EN
SCAN-LINE GREEN 250

2
Congratulations on your new wood stove, we are confident that you will be more than satis-
fied with your new Heta stove. Especially if you follow the following advice and instructions.
The Green 250 pellet stove is approved under EN 14785.
These approvals are your guarantee as a consumer that the pellet stove meets a number of
specifications and requirements which confirm that the stove is made of high-quality mate-
rials, that it is economical to use, and it is not harmful to the environment.
Please read these instructions for use carefully prior to installation and operation to avoid
personal injury or damage to building parts or the product itself.
Heta A/S
Jupitervej 22,
DK-7620 Lemvig
Phone: +45 9663 0600
E-mail: [email protected]
Copyright © 2014
Heta is a registered
trademark of Heta A/S
08.06.2022
0037-1795 Version 1,0
Printed in Denmark
Subject to printing errors
and changes.
Operating Instructions Contents
Before installation............................................................................... 3
1. Operating instructions........................................................................ 5
Before using ....................................................................................... 5
Filling of wood pellets ........................................................................ 5
First firing ........................................................................................... 5
Lighting............................................................................................... 5
Manual pellet feeding......................................................................... 5
Wood pellets ..................................................................................... 5
Display................................................................................................ 6
Menu structure ................................................................................... 6
Menu overview ................................................................................... 7
Timer setting .................................................................................... 11
Settings ............................................................................................ 12
Safety systems................................................................................. 12
2. Cleaning and Service ........................................................................12
Daily Clening .....................................................................................12
Monthly cleaning ...............................................................................13
Semi annually / Annually ...................................................................13
Vermiculitestone................................................................................14
Service interval..................................................................................14
Ash cleaning..................................................................................... 15
Cleaning interval................................................................................16
Troubleshooting ................................................................................17
Chimney fire ..................................................................................... 17
Stove data table EN 14785 .............................................................. 17
Adjustment of the combustion air.................................................... 18
Error codes and descriptions........................................................... 19
Wood pellets .................................................................................... 20
Parts ................................................................................................. 21
Garantee........................................................................................... 22
3. Installation Instructions .................................................................... 23

3
BEFORE INSTALLATION
Heta stoves are quality products, therefore, your
first impression is very important! We have a
good logistics network, which transports Heta
products with great care for our dealers. Never-
theless, when in transport or handling, damage
of the often-heavy stoves can occur. It is impor-
tant that upon receipt check your Heta product
completely and report any damage or defects to
your dealer.
The packaging must be disposed of as follows:
Wood, plastic and cardboard you can drop off
at your local recycling center.
Unpacking the stove
Mounting the display
2 x M4x6 0008-0036
1
2
3
5
4
1 x Display +
mounting brackets
Moving the stove

1
BETJENINGS- OG
OPSTILLINGSVEJLEDNING
DANSK DESIGN . DANSK KVALITET . DANSK PRODUKTION
www.heta.dk
DK
SCAN-LINE GREEN 250
Accessory External Fresh air kit
ø80 6000-026126
ø100 6000-024610
5032-0079
HETAclimate
Accessory
Accessory 0016-025501
Flue pipe
250 mm
Required tools are not supplied.
4
With your new wood stove you should find the following:
Operating /
Instruction manual
Data plate
CHR list
8056-0000-D
K
CE
Heta A/S Jupitervej 22
7620 Lemvig Denmark
Produk�ons år: 2016
Produkt beskrivelse Produk�onsnummer
Afstand �l brændbart materiale - bag ovn
Afstand �l brændbart materiale - side af ovn
Afstand �l møbel
Middel CO emission nominel last ved 13% O2
Middel CO emission I Mg/Nm3 ved 13% O2
656 Mg.
Røggas Temp. Nominel last
261 C°
Støv
> 3 Mg/Nm3
OGC
32 Mg/Nm3
Ydelse nominel last 4,5 k
w
Virkningsgrad nominel last
81%
Støv (NS 3058/3059) samlet vægtet par�kelemission
0,63 g/kg
Brændsel
Træ
ovnen er egnet �l intermiterrende drif
t
Anvend kun godkendt brændsel
Følg fabrikantens brugervejledning
DOP-Scan-line 1000 -XXXX-2016
0,05%
DS/EN 13240, AEA, NS 3058/3059, Aus §15A
120 mm
350 mm
850 mm
Scan-Line 1000 brændeovn

1
2
3
The bag of wood pellets must not be placed on
the rubber seal when filling pellets in the tank.
Open the pellet lid.
5
1. OPERATING INSTRUCTIONS
Before using
Before using the pellet stove, make sure
that the installation requirements have been
complied with. See page 24.
Filling of wood pellets
Remember to close the pellet lid, otherwise the
lid sensor will be activated and the wood pellets
will not be fed through.
First firing
The stove paint is fully cured from the factory,
but a minor unpleasant odour could still arise.
Lighting the stove
1. Check that the burn pot is in place in the
frame. See page 13.
2. Roll out the room temperature sensor which
is located on the back of the stove. Make
sure that it does not come into contact with
cold or hot surfaces.
3. Connect the stove to the mains using the
supplied cable.
4. Set the desired settings using the display.
See page 6.
5. Feed the pellets through as mentioned
below.
6. Start the stove. See page 7.
Manual pellet feeding
Before starting your stove for the first time or if
it has run out of wood pellets, the pellet feeder
may be completely empty and therefore ignition
may fail. To avoid this, on the display you can
manually fill the pellet feeder before starting the
stove.
Follow these steps to enable pill feeding:
Press and then select .
Activate manual pill feed by sliding the button
to the right. When the bottom of the burn pot
is covered with wood pellets, the pellet feed is
deactivated again and the burn pot is emptied
of pellets to ensure that the ignition sequence is
performed correctly.
Important
The burn pot must be empty
Of wood pellets before start-up.
Wood pellets
Only burn wood pellets in the pellet stove, Heta
recommends 6 mm wood pellets.

Display
Avoid water or other liquids coming
into contact with the electronics,
which may be destroyed and result
in technical failures or malfunction
and be dangerous to life.
6
24°
22°C
12:18 Ven 14 Ott 2016 Er52
Never open the stove door while
the stove is in operation. When
the oven is switched on, all sur-
faces and glasses are extremely
hot and should only be handled
using the appropriate protection.
Transparent protective film
It is recommended that you remove the protec-
tive film before using the Display to guarantee
the best performance of the sensitive (touch)
surface.
Main menu 1 Time and date Error code
Menu structure
11:24 Man 14 Apr 2019
24°
21°C
Er.01
OFF
Status
By swiping down from the top
of the display, you can see the
combustion state and the cur-
rent combustion effect.
OFF
Room temperature
Set temperature
Power Timer
P3
* Off / Daily / Weekly / Monthly
On/Off Settings Customization Info Chrono

Menu overview
1
Swipe for at tænde
ON
Slide to turn on/off.
2Justering
Power Thermostat Combustion Manuel pellet
setting feed
Power
P3
5Calibrazione Ventilatore
Power level
P4
P5
Auto
Power level
2
3
7

Thermostat
Temperature 40
3
5
10
24
22
23
25
26
Temperature
4
Combustion setting
Combustion levels
5
1
2
4
1
3
4
Combustion levels
8
To select room
temperature

5
Manual pellet feed
Manual pellet feed
00:00
Manual pellet feed
Manual pellet feed
Important
The burn pot
must be empty
for wood pellets
before start-up.
See page 5.
9

6
Settings System Menu Screen Menu
Settings
Settings
Time and Date
Language
Adjusting pellet quantity
Only for service
technician
Brightness
Standby brightness
Display stand-by
Screen Saver
Control panel address
Restart Display
Alarm with sound
Delete errors
System Info
Background
Display Info
Text black/white
Display Menu
76
10
16
10
Table des matières
Autres manuels Heta Brûleur