Hensel EXPERT D 1000 Manuel utilisateur

U S E R M A N U A L //
Compact flash unit
// EXPERT D 500 / D 1000

RC
freemask
performing light
AUDIO SLAVE TEST
FULL PROP
RC FC
Made in Germany
HENSEL Profoto Air
1
20
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
18
19
22
21
23
17

F1 F2 F3 F4
F5
F6
F7
P1
P12
P2 P3 P4
P5
P6
P7
P10
P11
P9 P8
P1 P2 P3 P4
P13
P14
Strobe Wizard Plus / freemask
Profoto Air Remote Profoto Air Sync

User Manual Expert D 500/1000
4
HENSEL-VISIT GmbH & Co. KG
HENSEL-VISIT GmbH & Co. KG
Robert-Bunsen-Str. 3
D-97076 Würzburg-Lengfeld
GERMANY
Tel. +49 (0) 931 27881-0
Fax: +49 (0) 931 27881-50
E-mail: [email protected]
Internet: http://www.hensel.de
© HENSEL-VISIT GmbH & Co. KG, 2013
Distribution and reproduction of this documentation is not
permitted unless specically authorized. In case of violation,
payment of damages will be due. All rights reserved, including
rights created by patent grant, or registration of a utility model
or design (ISO 16016).
Subject to technical changes. Errors and omissions excepted.
The listed data are standard values and not to be regarded as
guaranteed values in a legal sense. Values can deviate depen-
ding on component tolerance.
Effective date: 07/2013

User Manual Expert D 500/1000
5
HENSEL-VISIT GmbH & Co. KG
1 Preface
Dear photographer,
By purchasing the Hensel-Visit compact ash unit
Expert D 500/1000, you have selected a high-quality and
high performance product.
Below, we want to give you some details and hints on how to
use this unit. These will ensure successful and productive work
with it in the coming years.
Observing this necessary information entitles you to warranty
adjustments, prevents damages, and extends the operational
life of the unit.
Hensel-Visit took great care and observed all pertinent regula-
tions in order to manufacture a safe product of highest quality.
Stringent quality checks ensure our high quality standard even
in large-scale production.
Please add your part and handle the equipment with the neces-
sary care.
If you have any questions regarding the use of this equipment,
feel free to call us any time.
We wish you great success and „good light.”
HENSEL-VISIT GmbH & Co. KG

User Manual Expert D 500/1000
6
HENSEL-VISIT GmbH & Co. KG
2 Content
1 Preface............................................................................5
2 Content...........................................................................6
3 Safety instructions ............................................................8
4 General ........................................................................11
Description...............................................................11
Scope of delivery ......................................................11
5 Technical data ...............................................................12
6 Summary of control elements .........................................14
7 Initial use.......................................................................15
Acclimatization .........................................................15
Removing transport cap ............................................15
Mounting/removing safety dome ...............................15
Inserting ash tube ...................................................16
Inserting halogen lamp for modeling light..................16
Power supply ............................................................17
8 Operation .....................................................................19
Switch on/off ............................................................19
Modeling light ..........................................................19
Performance output adjustment .................................20
Flash Check .............................................................20
Test ash ..................................................................21
Flash readiness.........................................................21
Daily ash counter....................................................21
Synchronization ........................................................21
PM mode (in connection with Power Max L) ................22
9 Operation Strobe Wizard Plus.........................................24

User Manual Expert D 500/1000
7
HENSEL-VISIT GmbH & Co. KG
Summary of control elements ....................................24
Setting transmitter.....................................................24
Setting receiver .........................................................25
Output adjustment....................................................25
Switching the modeling light......................................25
10 Operation with freemask................................................26
Settings for the freemask method...............................26
11 Operation with Profoto Air..............................................28
Basic functions..........................................................28
Summary of control elements ....................................29
Preparing transmitter ................................................29
Remote trigger..........................................................30
Remote control .........................................................32
12 Maintenance .................................................................33
Regular maintenance................................................33
Replacing fuses.........................................................33
Updating software ....................................................34
Replacing ash tube..................................................35
Replacing modeling light ..........................................36
Error messages.........................................................37
Warranty..................................................................38
Disposal...................................................................38
13 Customer service points .................................................39
Manufacturer’s service ..............................................39
Service points listed in the Internet .............................39
14 Accessories....................................................................40
15 Subject index .................................................................41
16 EU declaration of conformity ..........................................42

User Manual Expert D 500/1000
8
HENSEL-VISIT GmbH & Co. KG
3 Safety instructions
In addition to the general rules for handling electrical equip-
ment, the following safety precautions must be observed.
Read and observe the below listed information before initial
operation of the equipment.
Supply a copy of the safety precautions when selling, leasing, or
otherwise distributing this equipment.
ATTENTION!
Improper handling of the device, non-compliance with the safety
hints below, or tampering with the safety features can cause
property damage, bodily injury, electric shock, or even death.
The compact ash unit Expert D 500/1000 is intended for
professional use inside the studio. It is only to be used with the
accessories described in this manual and approved by Hensel-
Visit.
The equipment may not be used for any other purpose than
described above, especially not for other electrical applications.
Set-up and initial operation
• Do not use ash units in explosive environments.
• Before connecting the equipment to the power supply, make
sure that the mains voltage corresponds to the specications
listed on the unit’s specication plate.
• Compact ash units and generators must only be connected
to grounded power supply systems.
• Check the protective conductor function of the power supply
before initial use.
• Only use plugs/connectors with awless contacts. Burned or
corroded plug contacts can cause res. Defective plugs can
cause substantial damage to the plug socket.
• Do not connect accessories from other manufacturers, even
when these look similar or alike.
Normal use
Abnormal use

User Manual Expert D 500/1000
9
HENSEL-VISIT GmbH & Co. KG
• To prevent damages and tripping hazards, avoid laying
cables on the oor. If this is not possible, make sure that
the cables cannot be damaged by vehicles, ladders, etc.
• Damaged cables and housings need to be replaced imme-
diately by an authorized service department.
• Keep the minimum distance around the equipment unobst-
ructed to ensure proper ventilation.
• Keep core ducts unobstructed during operation to ensure
proper air supply.
• Do not insert objects into core ducts.
• Do not place any objects on top of the equipment (coffee
cups, vases, containers lled with water, etc.).
• Protect the equipment from moisture, dripping or splashing
water.
• Choose safe locations for set up and make sure that the
equipment cannot fall into pools or bodies of water. Never
Never run cables directly along or even through pools or
bodies of water.
• Keep proper distance from ammable materials like deco-
rative fabrics or paper to prevent the risk of re.
• Secure the equipment with a back-up support when atta-
ching it to ceilings or pantographs. Use the tilt bracket’s
safety screw 11 and secure the device additionally with a
safety rope. Suitable safety ropes can be purchased from
Hensel-Visit, see „14 Accessories“ on page 40.

User Manual Expert D 500/1000
10
HENSEL-VISIT GmbH & Co. KG
Generators, compact flash units and flash heads
ATTENTION!
Defective ash tubes and false handling can pose a mortal
danger.
A damaged ash tube can mean mortal danger because you
could come in contact with the electrodes conducting high vol-
tage. Therefore, never touch exposed electrodes inside the ash
tube!
Before replacing ash tubes or modeling lights, the unit must
be switched off and disconnected from the power supply or
the generator. Even when the unit is switched off and properly
disconnected from the power supply, the capacitor could still be
highly charged in case of a malfunction. This means touching
the device could pose a life-threatening danger.
Halogen lamps and ash tubes may burst and must only be
operated with properly mounted Hensel safety dome.
ATTENTION!
Contact with capacitor voltage can pose mortal danger.
Opening the housing or repairs of the unit must only be done by
an authorized customer service provider.
Working with the equipment
• Do not ash into eyes at short distances since this may lead
to eye damage.
• Do not look directly into the ash tube or the reector. The
ash could be triggered accidentally.
• Regularly air closed rooms to prevent build-up of inadmissi-
ble ozone concentrations which can occur due to the use of
high-powered ash systems.
• Cover the equipment which is not in use with a proper dust
guard when working in a dusty environment.
Table des matières
Autres manuels Hensel Lampe de poche