15 16
五、 FAULT ANALYSIS AND TROUBLESHOOTING
Fault Source matter Checking method Solution
Motor doesn‘t rotate
Control box doesn't
display(Left area)
Control box doesn't
display(right area)
Display temperation
is 300℃
Cables between Main control
board to the foot phase
Main control board
5V power supply
24V power supply
PCB of the display box
Cables between main control
board to the display
Main control board of ironing
table
Cables between Ironing table
to steam generator
The main board of steam
generator
Main control board of ironing
table
Main control board of ironing
table
Temperature sensing cables
Temperature sensor
The interface
Short circuit the foot phase interface on the main
control board and check whether the main LED is on
Disconnect the foot phase signal connection port on
the main control baord, short-circuit with a cap, check
whether the LED light up / whether the motor is
rotating
Use a multimeter to measure whether the connection
is virtual.
Observe the indicator light of the power supply. If the
indicator light is not on, check the switching power
supply and the power supply. Otherwise, check the
cablses from the switch power supply to the main
control board of the ironing table.
Observe the indicator light of the switching power
supply. If the indicator light is not on, check the
switching power supply and the switching power
supply. Otherwise, check the wire from the switch
power supply to the main control board of the ironing
table board of the ironing table.
Replace the new display board and check whether it
is work properly.
Disconnect the main power supply and use a
multimeter to measure whether there is a short circuit
at both ends .
Disconnect the main power supply and use a
multimeter to measure whether there is a short circuit
at both ends .
Use the multimeter to measure the voltage at dc gear
and AC gear respectively. If there is voltage, it is
normal .
Use the multimeter to measure the on-off of j6-15 to
chip u10-2.
Use a multimeter to test both ends of the wire with a
resistance of 20K. If there is about 1100r, it is ok.
Use a multimeter to test both ends of the wire with a
resistance of 20K. If there is about 1100r, it is ok.
Crimp terminal tightly.
replace main control board
Cables between the main control
board to the AC contactor
四、 Maintaince and Maintaince Methods
Figure 4
Fault Analysis
Control box (Figure 4)
•Drying of platform board and arm
•adjustion of suction air volume
(* increase 15min for each press,
120min for maximum timing, cycle
switching) (* arm is optional part)
(*suction air volume adjustion is
only supported for 220V model)
③
Clean the dust, fluff and lint of each part of the ironing table before operation,and keep the
working environment clean and tidy.
After start-up, confirm whether the ironing table can absorb air and heat, whether there is
steam in the iron (open the iron to output steam for about 5 to 15 seconds, until the iron
steam does not contain water drops), etc., and then it can be used normally.
Step the foot phase, check the wind force and damper, listen for abnormal sound, and check
whether the foot phase is flexible and reliable.
When leaving temporarily or OFF work, the machine must be shut down. It is prohibited that
keep the machine power ON and steam generating when the personnel leave.
Shut down the machine and clean the ironing table before OFF work.
Clean or replace the sponge pad,If the air volume becomes less and less, otherwise the
ironing effect will be affected.
In case of abnormal sound or peculiar smell of the ironing table during operation, turn off the
power immediately and contact a mechanic for checking and fixing.
Perform an overall safety checking on the ironing table weekly.
Check the iron frequently for dirt and keep the ironing table clean.
In case of iron failure during operation, contact professional maintenance engineer for
repairing.
Maintenance engineer shall regularly check the iron for surface cleaning and internal inspec-
tion and maintenance.
Replace cables / fix virtual
connecting
Replace the new display
board
Replace cables / fix virtual
connecting
replace a main control
board
Replace cables / fix virtual
connecting
Replace cables / fix virtual
connecting
replace a main control
board
replace a main control
board
Replace cables / fix virtual
connecting
replace a Temperature
sensor
Replace cables / fix virtual
connecting