2.2.1 Status on the display
Auto
Mode
Defrost
Mode
Heating
Mode
Cooling
Mode
Timer
ON/OFF
2.2.2. Clock setting
1. Hold for5secondstoentertheclocksetting.88:88isashingonthedisplay
2. Press or to adjust the time. Then, press toconrmandexit.
3. If no settings are made within 30 seconds, any changes will be lost and the controller will exit
the clock setting.
2.2.3. Timer on and off
1. Hold the for10secondstoenterthetimersetting.The“ON”willbeashingtoenterthe
Timer ON setting. Press the or to adjust Timer ON time. You can choose Timer ON
(Display: ON), or Repeat Timer ON (Display: 1 ON) by pressing . Then press toconrm.
2. Whenthe“ON”stopsashing,and“OFF”isashing,youentertheTimerOFFmode.Pressthe
or to adjust Timer OFF time. You can choose Timer OFF (Display: OFF), or Repeat Timer
OFF (Display: 2 OFF) by pressing . Then press toconrm.
3. After entering the Timer ON/OFF setting, press directly without adjusting the time to
cancel the relevant Timer setting.
4. If no settings are made within 30 seconds, any changes will be lost and the controller will exit
the Timer ON/OFF setting.
Note: If daily time schedule is required (normal) repeat timers must be set.
2.2.4 Silence mode
1. The Smart mode as default will be activated when the machine is turned on. And the display
shows .
2. When machine is on, press button to enter the Silence mode. will show. Press again
to exit.
2.2.5 Compulsory defrost
1. When the machine is on heating mode and the compressor is working continuously for
10 minutes, press both and buttons for 5 seconds to start compulsory defrost.
(Note: the break between compulsory defrost needs to be more than 30 minutes.)
2. Thedefrostsymbolwillashwhenthemachineisincompulsorydefrostmodeorautodefrost
mode.
3. Compulsory defrost will take the same amount of time as auto defrost.
Heatseeker VortexC Inverter Heat Pump