5. ADD/REMOVE
Please read this before installation
The primary controller/gateway has a mode for adding or removing
devices. Please refer to your primary controller manual on how to set
the primary controller in add/remove mode. The device may only be
added or removed from the network if the primary controller is in add/
remove mode. When the device is removed from the network, it will
NOT revert to factory settings.
An always listening node must be powered continuously and reside on
a fixed position in the installation to secure the routing table. Adding the
device within a 2m range from the gateway can minimize faults during
the Interview process.
There are two ways to add the device to a Z-Wave network.
5.1 Method 1: Standard (Manual)
Add/remove mode is indicated on the device by a blinking green LED.
It indicates this for 90 seconds until a timeout occurs, or until the
module has been added to/removed from the network.
To start the configuration process, press the reset button 3 times in
rapid succession. The LED will light up in green for 3 seconds if adding/
removing is successful. The device is now ready for use with default
settings.
NB! When the device is removed from the gateway, the parameters are
not reset. To reset the parameters, see Chapter 6 ”Factory reset”.
If inclusion fails, please perform a ”remove device” process and try
again. If inclusion fails again, please see Chapter 6 “Factory reset”.
5.2 Method 2: SmartStart (Automatic)
SmartStart enabled products may be added to a Z-Wave network
by scanning the Z-Wave QR-Code on the product if your primary
controller supports SmartStart inclusion. No further action is required
and the SmartStart product will be added automatically after being
powered on within range of the primary controller.
6. FACTORY RESET
Press and hold the reset button. After 3 seconds the LED will start to
blink in green. After 20 seconds the LED will shine solid green for 3
seconds. You may now release the button.
Please use this procedure only when the network primary controller is
missing or otherwise inoperable.
7. STARTUP
After powering up the device for the first time, all the parameters will
have default settings.
8. LED BLINKING PATTERNS DESCRIPTION
The device supports numerous LED blinking patterns to make it as
easy as possible to identify what the device is doing.
Device Not in Network
The LED will flash in red when the
device is not added to a Z-Wave
network
Add/Remove
When device enters add/remove
mode the LED will flash green.
If successful, the LED will light up in
green for 3 seconds.
If unsuccessful, the LED will light up in
red for 3 seconds.
Communication
The device should blink green every
time it sends data over Z-Wave
Factory Reset
If the button is pressed for more than
3 seconds, the GREEN LED will start
flashing.
When the button has been pressed
for 20 seconds, the GREEN LED will
light up for 3 seconds.
Figure 1 (success)
Within the 3 second period the but-
ton must be released. If the button is
released within this period, the device
will reset and start flashing because it
is not included in a gateway.
Figure 2 (fail)
If the button is released before the
3 second period, the device will
indicate fail by turning RED LED on for
3 seconds.
Figure 3 (fail)
The button MUST be released
between 20 and 23 seconds for local
reset to take place. If held longer, the
device will ignore the command.
9. QRCODE PLACEMENT DSK
The QR-Code is needed when including a device using S2 security or
SmartStart. The DSK can be found in the QR-Code and is located;
• On the product.
• On the Quick Guide.
• On the gift box.
0s 1s 2s 3s
Z-Wave Data transmission indication
4s 5s
Figure 1
Figure 2
Figure 3