SYMPTOM POSSIBLE CAUSE SOLUTION
Lights will not come on. 1. Light switch is turned off.
2. Flood lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a new installation.
6. Light control aimed in wrong direction.
1. Turn light switch on.
2. Check ood lamp and replace if burned out.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Verify wiring is correct.
6. Re-aim light control to cover desired area.
Lights come on in day-
light.
1. Light control may be installed in a relatively dark
location.
2. Light control is in TEST.
1. The xture is operating normally under these condi-
tions.
2. Set control switch to 1, 5, or 10 minutes.
Lights come on for no
apparent reason.
1. Light control may be sensing small animals or auto-
mobile trafc.
2. Range is set too high.
1. Re-aim light control.
2. Reduce range.
Lights turn off too late in
Dusk-to-Dawn setting.
Lightcontrolmaybe installed in a relatively dark location. Relocate light control, or use 3 hour or 6 hour setting.
Lights stay on continu-
ously.
1. A ood lamp is positioned too close to the light control
orpointed at nearbyobjects that causeheat to trigger
the light control.
2. The light control may be picking up a heat source
like an air vent, dryer vent, or brightly painted, heat-
reective surface.
3. Light control is in manual mode.
1. Reposition the ood lamp away from the light control
or nearby objects.
2. Reduce range.
3. Switch light control to AUTO.
Lights ash on and off. 1. Heat or light from the ood lamps may be turning the
light control on and off.
2. Heat being reected from other objects may be turn-
ing the light control on and off.
3. Light control is in the TEST mode and warming up.
4. Light may be leaking through the ood lamp reec-
tors.
1. Reposition the ood lamp away from the light control.
2. Reposition light control.
3. Flashing is normal under these conditions.
4. Replace the ood lamps with new high quality PAR
38 lamps. (Make sure the metal lamp protectors are
installed).
Lights ash once, then
stayoffin manual mode.
Light control is detecting its own lights. Reposition ood lamps to keep area below the light
control relatively dark.
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 180°
Electrical Load. . . . . . Up to 300 Watt Maximum Tung-
sten [Up to 150 Watt maximum
each bulb holder.]
Up to 60 Watt Maximum self-
ballasted CFL [Up to 30 Watt
maximum each bulb holder.]
TROUBLESHOOTING GUIDE
Power Requirements. 120 VAC, 60 Hz
Operating Modes. . . . TEST, AUTO, and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable