HDL SB-DN-512DMX Manuel utilisateur

User Manual
SB-DN-512DMX
DMX Controller – User Manual
Document updates:
Version
Date
Description
V1.0
2015.08.17
Finish new document

User Manual
SB-DN-512DMX
DMX Controller – User Manual
INDEX
1. Overview....................................................................................................................................1
1.1 General Information.......................................................................................................... 1
1.1.1 Description.............................................................................................................. 1
1.1.2 Mounting..................................................................................................................1
1.2 Function Qualities Description........................................................................................ 1
1.3 Device Description............................................................................................................ 2
2. Safety Instructions....................................................................................................................2
3. Technical Data.......................................................................................................................... 3
4. Installation................................................................................................................................. 4
4.1 Diagram...............................................................................................................................4
4.2 HDL BUS Pro Description................................................................................................5
4.3 Commissioning.................................................................................................................. 5
5. Software Configuration............................................................................................................6
5.1 Basic setting....................................................................................................................... 6
5.1.1 Change the ID of the device................................................................................ 6
5.1.2 Remark.................................................................................................................... 6
5.1.3 IP and IP MAC........................................................................................................ 6
5.2 Area Setup.......................................................................................................................... 7
5.3 Channel parameter........................................................................................................... 8
5.3.1 Display format.........................................................................................................8
5.3.2 Remark.................................................................................................................... 9
5.3.3 Changing attribute..................................................................................................9
5.3.4 Load test..................................................................................................................9
5.3.5 Modify patch......................................................................................................... 10
5.4 Scene Setup.....................................................................................................................10
5.5 Sequence..........................................................................................................................11
6. Operation On LCD Screen................................................................................................... 13
7. FAQ.......................................................................................................................................... 15
8. NOTES.....................................................................................................................................18

User Manual
SB-DN-512DMX
DMX Controller – User Manual 1
1. Overview
1.1 General Information
1.1.1 Description
SB-DN-512DMX is a high performance show controller developed by HDL. HDL panels
can control the DMX devices (e.g. Computer lighting, Moving heads) which can receive
DMX1990 signal or NET DMX signal via SB-DN-512DMX.
1.1.2 Mounting
Standard 35mm Din Rail Installation
Inside Distribution Box(DB)
1.2 Function Qualities Description
It has up to 16 areas, Each area can set 0~1024 scene, and the scene’s running time
is up to 60 minutes.
Total is 99 sequences, 4 running modes are available for each sequence: forward,
backward, forward & backward, random.
DMX512 (1990 version).
Support Art Net / HDN Net DMX protocol.
Low threshold, high threshold, maximum threshold are all available for each channel
for different devices.
Each channel has light protection delay time (0~25 seconds).
Each channel has protection delay time for power on after power off (0~60 minutes).
Gateway between HDL Buspro and Ethernet.

User Manual
SB-DN-512DMX
DMX Controller – User Manual 2
1.3 Device Description
`
2. Safety Instructions
Danger
Serious injuries, fire or property damage possible. Please read and follow safety
instructions fully.
Risk of fatal injury from electrical current
All work on the device should only be carried out by trained, fitted and skilled
electricians. Before working on the device or before exchanging light bulbs,
a. Line and Neutral
b. DMX512 signal
connection terminal
c. LCD screen
d. Control buttons
e. Ethernet port: RJ45
f. LED indicator
g. Provides DC power
for other devices
h. Buspro terminal
○
a
○
b
○
c
○
d
○
e
○
f
○
g
○
h
Control buttons:
【Enter】Confirm button
【Esc】Esc button
【 △ 】 Page up — used for modifying the setting, when you
press, the value will increase
【▽】 Page down — used for modifying the setting, when you
press, the value will decrease
【<】Left Move — used for selecting item and cursor location
【>】Right Move — used for selecting item and cursor location
Note: When you press all direction keys at the same time, the
module will be reset.

User Manual
SB-DN-512DMX
DMX Controller – User Manual 3
disconnect mains voltage and switch off circuit breakers.
Device can be damaged
Do not bypass or short-circuit the dimmer. Do not connect any LED, lights with
integrated dimmers or compact fluorescent lamps that are not specifically
suitable for dimming.
Product Manipulation
Only operate the device according to the specifications stated in the Technical
data. Opening the housing of the device causes the immediate end of the
warranty period.
3. Technical Data
Electric Parameter :
Power input
DC12~30V
Power consumption
200mA/DC24V
Signal type
DMX512(1990)
4CH/3A
HMI
128×64 raster graphic LCD
6 soft-touch buttons
RJ45
RJ45-TCP/IP network interface
Control channel
512
Ethernet network interface
10Mbps/RJ45
Environmental Condition:
Working temperature
0%~45%
Working relative humidity
Up to 90%
Storage temperature
-20%~+60%
Storage relative humidity
Up to 93%
Approved
CE
RoHS
Production information:
Dimensions
144×90×66 (mm)
216×90×66 (mm)

User Manual
SB-DN-512DMX
DMX Controller – User Manual 4
Weight
428.6(g)
716(g)
Housing material
Nylon, PC
Installation
35mm Din Rail installation
Protection degree
IP20
4. Installation
4.1 Diagram

User Manual
SB-DN-512DMX
DMX Controller – User Manual 5
4.2 HDL BUS Pro Description
Connector Information
Buspro
Buspro/KNX
CAT5/CAT5E
DC24V
Red
Brow/Orange
COM
Black
Brow white/Orange white
DATA-
White
Blue white/Green white
DATA+
Yellow
Blue/Green
4.3 Commissioning
a) Unlock the LCD screen of 512DMX. (Press [ENTER] and [ESC] buttons together, and
then press [ENTER] button again to enter the PASSWORD interface, fill in the correct
password to unlock the LCD screen of 512DMX)
b) After filled in the correct password, follow below steps to check its ID: ‘1 SYSTEM
SETUP 1 D-Bus ID Set’
c) Open the HDL-BUS Pro Setup tool.
d) Click the search button, it will show a new window, click search button, search the
online devices. Click the “Add all” button, the devices which be searched will be add
in ‘ON-line devices’ list.
e) find the 512DMX on the ‘ON-line devices’ list
Password:4573
☺

User Manual
SB-DN-512DMX
DMX Controller – User Manual 6
5. Software Configuration
5.1 Basic setting
5.1.1 Change the ID of the device
Every HDL Buspro device has one Subnet ID and one Device ID, the Device ID should be
unique in its subnet.
5.1.2 Remark
Generally set it like “for living room”, or “in DB3”(distribution box 3) to indicate some info.
5.1.3 IP and IP MAC
The factory default IP and IP MAC are 192.168.10.250 and M-I-R-255-255-255. To avoid
conflict, you can connect only one at first, modify and save it before you connect another
one and configure.
DMX channel: the start channel of NET DMX signal. The range of HDL-Net is 001~255;
the range of Art-Net is 000~255.
DMX port: the port for HDL-Net / Art-Net; if use Art-Net, this port will be fixed as 6454, no
need to change.

User Manual
SB-DN-512DMX
DMX Controller – User Manual 7
5.2 Area Setup
Below screen shot shows all 512 channels of SB-DN-512DMX are not assigned to any
area, actually there is no area yet.
Suppose according to the wiring, channel1 to 16 are used to control 16 LEDs in area1,
channel 17 to 50 are used to control 33 LEDs in area2. The configuration steps would be
like this:
a) Click “Create area”, area 1 is created, we can find and select it in “Select area”.
b) Select channel 1 to 16 and move them from left block to the right block, click “save”.
c) Click “Create area”, area 2 is created, we can find and select it in “Select area”.
d) Select channel 17 to 50 and move them from left block to right block, click “save”.
e) Exit this “Area setup” window, we can name the two areas, i.e., area1 and area2.