Hamilton Manufacturing Corporation DRS Guide de démarrage rapide

Document#101-0007 1 9/12/05
RNS, DRS, & ER-60 M-Line
Operational Manual

Document#101-0007 2 9/12/05
TABLE OF CONTENTS
I. INSTALLATION .....................................................................................................4
Mounting ........................................................................................................................................ 4
Electrical ........................................................................................................................................ 4
II. VALIDATOR MOUNTING............................................................................ 5-10
STAMountingInstructions ........................................................................................................... 5
STA/StackerMountingDiagram .................................................................................................. 6
Coinco®/Mars®MountingInstructions ...................................................................................... 7
Coinco®PartsLayout ................................................................................................................... 8
Mars®Parts Layout ..................................................................................................................... 9
PartsIndex ................................................................................................................................... 10
III. PARTS ........................................................................................................... 11-12
APPENDICES
APPENDIX A - 1-H Harness Diagram...................................................................13
APPENDIX B - Bill Denomination Mylar Instructions........................................14

Document#101-0007 3 9/12/05
ABOUT THIS MANUAL
Thismanualwillprovidetheoperatorwithimportantinformationaboutinstallingandmaintainingthe RNS,
ER-60orDRS Changer.InformationisalsoprovidedfortheHopper,Stacker,andController. Basicmounting
informationisprovidedfortheValidator(s).Forfurtherinformation,pleasereferto the appropriateValidator
manual.Toobtain assistance fromthemanufacturer,please call(800)837-5561 or (419)867-4858.
Whencallingforassistance,it is very importantto have serialnumbers readily available.Please record these
numbersin the spacesprovided.(Note that theDRShas dual components.)
RNS / DRS / ER-60 SERIAL #
VALIDATOR MODEL, SERIAL & VERSION #
(MODEL DRS) #
SINGLE STACKER SERIAL #
(MODEL DRS) #
DUAL STACKER SERIAL #
(MODEL DRS) #
HOPPER SERIAL #
(MODEL DRS) #
CONTROLLER MODEL, SERIAL & VERSION #
(MODEL DRS) #
KEY / LOCK #
Pleasecompletethewarrantycard,which was includedwith your changer, and return itto the manufacturer.

Document#101-0007 4 9/12/05
I. Installation
Mounting
1. DURING INSTALLATION, REMOVEALLMAJOR COMPONENTS FROM
THECHANGER.
2. Cut anopening inthe wallmeasuring aminimumof34-5/8" Hx9"Wfor RNS, 34-
3/4" H x 18-1/8" W for DRS and 20-3/4" H x 15" W for ER-60.
3. Caulk aroundthe outsideedge oftheopening.
4. Place thecabinetintheopeningand press until the flange is flush on allsides.
5. Fasten thecabinet bybolting orweldinga2"angle iron onboth sidesofthecabinet.
Hamilton will not be responsible for injury due to improper installation.
FACEPLATE: 38 5/8" H x 12" Wfor RNS, 38 1/4" H x 21 5/8" Wfor DRS and 24-3/4" H x 18"W for ER-
60.
Electrical
Thischanger isoperatedon 120VAC, 60 Hz.This changerusesa 5AMPCIRCUITBREAKER.This unit
maybe hard-wired withconduitif desired.AGROUNDFAULTINTERRUPTERISREQUIRED.The
recommendedGroundFaultInterruptershouldhavethefollowingspecifications:
• 120 VAC
• 15 AMP
• 6-10mAtrip level
• Shouldnottrip whenpower isremovedfrom circuit.
Attached to the main harness is a 1-pin white Molex connected to a white wire. There should be a bright
yellowtagattachedtothiswirewiththefollowingwarning:
WARNING: Forsecurityreasons,thisplug shouldremaindisconnected until
suchtime asyouneedtoutilize thehopper’s manualrunswitch.
Thereisnoneedtoconnectthisplugfornormaloperation.Ifforsomereasonyouwishtoutilizethemanualrun
switch,besureto unplug theMolex afterward.

Document#101-0007 5 9/12/05
II. Validator Mounting
STA Mounting Instructions
1. Unplug thepower cordorremoveall powerfromthesystem at thecircuitbreaker.
2. Remove theexistingStackerandValidator.
3. Remove theValidatorbracket from the mountingstuds located onthe front wallof the
cabinet. Disconnecttheheater pad(if present)andremove it aswell.
4. Secure thenewValidatormounting bracket assembly(37-0055B)tothe studson thefront
wallofthecabinetusingfour 1/4-20 nuts.
5. Secure theadhesive backedfoamsealto the insideofthecabinet front aroundtheValidator
opening.
6. Connect thesmallend of the9-pin harness adapterto the STAValidator and theother end
tothesystemharness.
7. Slide theValidatorinto theValidator bracketfrom therear.
8. Connect theStackerharness and hangtheStackerfromtheback of theValidator mounting
bracket.

Document#101-0007 6 9/12/05
STA/Stacker Mounting

Document#101-0007 7 9/12/05
Coinco®/Mars® Mounting Instructions
Inthefollowingsection,partquantitiesarerepresentedbyparanthesis
andthe#indicatestheindexnumberaccordingtothediagramonpages
8-9.
1. Mount CoverPlate-#14to FillerPlate-#12using (2)10-24 x 3/8 Philips head screws-#13.
2. Then mounttofaceof cabinetusing(4)1/4-20Hex nuts-#3and (4) internallockwashers-
#4.
3. Take Slider-#9 andValidator Face Plate-#10 and insert (4) 8-32 x 5/8 ballstuds-#11
throughFace Plate andinsertintofront ofcabinet.Thentake (4)8-32 nylonnuts-#8and
tightenonballstuds.
4. Mount (4)10-32x 3/16 Phillisterhead screws-#17 toValidatorPlate-#7. Screwingthem
frominsidetoout.
5. Then mountSecurity Bracket-#1tothebottom of thetwoPhillisterhead screws soit
swingsupanddown.
6. TakeU-Channel-#5and place itinsideofValidatorPlate-#7 and matchupwith studs on
faceofcabinet.
7. Then bytaking(4) 1/4-20Hexnuts-#3 and(4)1/4 internallockwashers-#4, mountto
cabinetandtightendown.
8. Then takeValidatorand placeinto U-Channel-#5andmount it with(4)8-32x5/8Philips
headscrews-#2. Then swingSecurityPlate-#1up andhookontothe toptwo Phillister
headscrews-#17 ofValidator Plate-#7.
9. For theCoinco®Validator only, take PowerPack Holder-#15 andmount tostuds on door
using(2) 6-32Hexnuts-#16.
10. For theMars®Validator only,Take Relay Box-#15and mount abovePower Box onface
ofcabinetusing (2)10-24 nylonlocknuts-#16.

Document#101-0007 8 9/12/05
Coinco® Parts Layout
COINCO VALIDATOR
CABINET FACE
LEXAN
CABINET DOOR
17
16 15
14
1
13
12
11
10
9
8
7
6
5
4
3
2

Document#101-0007 9 9/12/05
CABINET FACE
LEXAN
MARS VALIDATOR
CABINET FACE
1
2
34
56
78
910
11
12
13
14
15
16
17
Mars® Parts Layout

Document#101-0007 10 9/12/05
Parts Index
ITEM # PART # MOUNTING PARTS FOR COINCO QTY.
1 60-2053 SECURITY BRACKET 1
2 90-0145 #8-32 X 5/8 PHILLIPS HEAD SCREW 4
3 90-0331 #1/4-20 HEX NUT 4
4 90-0403 #1/4 INTERNAL LOCK WASHER 4
5 60-2051 U-CHANNEL 1
6 90-0629 #10-32 X 1/2 THUMB SCREW 1
7 60-2050 VALIDATOR PLATE 1
9 60-2054 SLIDER 1
10 60-0282 VALIDATOR FACE PLATE 1
11 90-0517 #8-32 X 5/8 BALL STUD 4
13 90-0148 #10-24 X 3/8 PHILLIPS HEAD SCREW 2
17 90-0628 #10-32 X 3/16 PHILLISTER HEAD 4
ITEM # PART # MOUNTING PARTS FOR MARS QTY.
1 60-2055 SECURITY BRACKET 1
2 90-0145 #8-32 X 5/8 PHILLIPS HEAD SCREW 4
3 90-0331 #1/4-20 HEX NUT 4
4 90-0403 #1/4 INTERNAL LOCK WASHER 4
5 60-2051 U-CHANNEL 1
6 90-0629 #10-32 X 1/2 THUMB SCREW 1
7 60-2050 VALIDATOR PLATE 1
8 90-0321 #8-32 NYLON NUT 4
9 60-2052 UVM SLIDER 1
10 60-0282 VALIDATOR FACE PLATE 1
11 90-0517 #8-32 X 5/8 BALL STUD 4
13 90-0148 #10-24 X 3/8 PHILLIPS HEAD SCREW 2
17 90-0628 #10-32 X 3/16 PHILLISTER HEAD 4
Ce manuel convient aux modèles suivants
2
Table des matières
Manuels Changeur de monnaie populaires d'autres marques

American Changer
American Changer AC6007 Manuel utilisateur

American Changer
American Changer AC2007 Manuel utilisateur

Coinco
Coinco vortex Instructions d'utilisation d'origine

American Changer Corp.
American Changer Corp. AC401-2 Guide de configuration

Coinco
Coinco Guardian 6000 Manuel utilisateur

Comestero
Comestero Suzohapp Multi PRO Manuel utilisateur