Greenlee CMA-40 Manuel utilisateur

999 3250.4 © 1999 Greenlee Textron IM 1392 7/99
CMA-40
CLAMP-ON
CURRENT
ADAPTER
ADAPTADOR DE
CORRIENTE CON
PINZA
ADAPTEUR DE
COURANT A PINCES
Read and understand all of the instructions and safety
information in this manual before operating or servicing this tool.
Lea y entienda todas las instrucciones y la información sobre
seguridad que aparecen en este manual, antes de manejar estas
herramientas o darles mantenimiento.
Lire attentivement et bien comprendre toutes les instructions et
les informations sur la sécurité de ce manuel avant d’utiliser ou de
procéder à l’entretien de cet outil.
INSTRUCTION MANUAL
MANUAL DE INSTRUCCIONES
MANUEL D’INSTRUCTIONS

2
Description
The Greenlee CMA-40 Clamp-on Current Adapter is an AC-current measuring accessory.
It is intended to be connected to any multimeter (purchased separately) capable of reading
AC millivolts.
The CMA-40 clamp takes a current input and produces a voltage output. The ratio is 1000:1.
Every amp of input produces a millivolt of output.
Safety
Safety is essential in the use and maintenance of Greenlee tools and equipment. This
instruction manual and any markings on the tool provide information for avoiding hazards and
unsafe practices related to the use of this tool. Observe all of the safety information provided.
Purpose
This instruction manual is intended to familiarize all personnel with the safe operation and
maintenance procedures for the Greenlee CMA-40 Clamp-on Current Adapter.
Keep this manual available to all personnel.
Replacement manuals are available upon request at no charge.
and are registered trademarks of Greenlee Textron.
KEEP THIS MANUAL

CMA-40
3
Important Safety Information
This symbol is used to call your attention to hazards or unsafe practices which could
result in an injury or property damage. The signal word, defined below, indicates the
severity of the hazard. The message after the signal word provides information for
preventing or avoiding the hazard.
SAFETY ALERT SYMBOL
Immediate hazards which, if not avoided, WILL result in severe injury or death.
Hazards which, if not avoided, COULD result in severe injury or death.
Hazards or unsafe practices which, if not avoided, MAY result in injury or property
damage.
Read and understand this material before operating or servicing
this equipment. Failure to understand how to safely operate this
tool can result in an accident causing serious injury or death.

4
Important Safety Information
• Do not operate with the case open.
• Before opening the case, remove the jaw from the circuit.
Failure to observe these warnings can result in severe injury or death.
• Do not attempt to repair this unit. It contains no user-serviceable parts.
• Do not expose the unit to extremes in temperature or high humidity.
See Specifications.
Failure to observe these precautions can result in injury and can damage the unit.
Electric shock hazard:
• Do not use the unit if it is wet or damaged.
• Use test leads or accessories that are appropriate for the application. See the
category and voltage rating of the test lead or accessory.
• Inspect the test leads or accessory before use. The item(s) must be clean and dry,
and the insulation must be in good condition.
Failure to observe these warnings can result in severe injury or death.
Electric shock hazard:
Contact with live circuits can result in severe injury or death.

CMA-40
5
Identification
1. Jaw Unit
2. Leads
3. Lever
Operation
Note: The CMA-40 requires a multimeter (purchased separately) capable of reading AC millivolts.
1. See the instruction manual supplied with the multimeter.
2. Connect the CMA-40 to the voltage input terminals of your multimeter. Set the meter to
read AC voltage.
3. See Typical Measurements for illustrations of typical uses.
4. Test the unit on a known functioning circuit or component. If the unit does not function as
expected, send the unit to Greenlee for repair.
5. Take the reading from the circuit to be tested. If the resolution is not satisfactory, remove
the meter from the circuit and change to the next lower range.
Electric shock hazard:
Contact with live circuits can result in severe injury or death.
1
3
2

6
Typical Measurements
Clamp Around
Line Splitter
Clamp Around Wire
Notes:
• Clamp the jaw around one conductor only.
• Close the jaw completely.
• Center the wire in the jaw for highest accuracy.
Notes:
• The Greenlee 93-30 Line Splitter is divided. One section
renders amps; the other renders amps multiplied by 10.
• Close the jaw completely.
• Center the line splitter in the jaw for highest accuracy.
COMmA µAA V
COMmA µAA V
Multimeter set to
read AC voltage.
Note: Every amp of input
produces a millivolt of output.
Multimeter set to
read AC voltage.
Note: Every amp of input
produces a millivolt of output.

CMA-40
7
Accuracy
• See the Specifications section for operating conditions.
• Accuracy is specified as follows: ±(a percentage of the reading + a fixed amount)
at 23 °C ±5 °C (73.4 °F ±9 °F), 0% to 75% relative humidity.
• Accuracy is for the CMA-40 only. See the instruction manual supplied with your multimeter
for its accuracy.
Accuracy Table
Specifications
Measurement Range: 0.1A to 400A (AC only)
Voltage Output: 1 mV output per 1 amp input (AC only)
Output Impedance: 75 Ω
Temperature Coefficient: 0.2 x (specified accuracy) per °C below 18 °C or above 28 °C
Operating Conditions: 0 °C to 45 °C (32 °F to 113 °F), 0% to 75% relative humidity
Elevation: 2000 m (6500') maximum
Indoor use
Storage Conditions: –20 °C to 60 °C (–4 °F to 140 °F), 0% to 75% relative humidity
Jaw Opening: 30 mm (1.18")
Pollution Degree: 2
Overvoltage Category: Category II, 600 Volts
)spmACA(tupnIycaruccAegnaRycneuqerF
A053ot1.0)A5.0+%9.1(± zH06ot05
A004ot053)A1+%2.3(±

8
Descripción
El Adaptador de corriente con pinza modelo CMA-40 de Greenlee es un accesorio de medición
de corriente alterna (CA).
Está diseñado para conectarse a cualquier multímetro (vendido por separado) capaz de leer
milivoltios de CA.
La pinza del CMA-40 toma la lectura de la corriente y produce una lectura de voltaje. La relación es
1000:1. Cada amperio de entrada produce un milivoltio de salida.
Acerca de la seguridad
Es fundamental observar métodos seguros al utilizar y dar mantenimiento a las herramientas y equipo
Greenlee. Este manual de instrucciones y todas las marcas que ostenta la herramienta le ofrecen la
información necesaria para evitar riesgos y hábitos poco seguros relacionados con su uso.
Siga toda la información sobre seguridad que se proporciona.
Propósito de este manual
Este manual de instrucciones tiene como propósito familiarizar a todo el personal con los
procedimientos de operación y mantenimiento seguros para el Adaptador de corriente con pinza CMA-
40 de Greenlee.
Mantenga siempre este manual al alcance de todo el personal.
Puede obtener copias adicionales de este manual de manera gratuita, previa solicitud.
y son marcas registradas de Greenlee Textron.
CONSERVE ESTE MANUAL

CMA-40
9
ImportanteInformaciónsobreSeguridad
Este símbolo se utiliza para indicar un riesgo o práctica poco segura que podría ocasionar
lesiones o daños materiales. Cada uno de los siguientes términos denota la gravedad del
riesgo. El mensaje que sigue a dichos términos le indica cómo puede evitar o prevenir
ese riesgo.
SÍMBOLO DE ALERTA
SOBRE SEGURIDAD
Peligros inmediatos que, de no evitarse, OCASIONARÁN graves lesiones o incluso la muerte.
Peligros que, de no evitarse, PODRÍAN OCASIONAR graves lesiones o incluso la muerte.
Peligro o prácticas peligrosas que, de no evitarse, PUEDEN OCASIONAR lesiones o daños
materiales.
Lea y entienda este documento antes de manejar esta herramienta o
darle mantenimiento. Utilizarla sin comprender cómo manejarla de
manera segura podría ocasionar un accidente, y como resultado de
éste, graves lesiones o incluso la muerte.

10
ImportanteInformaciónsobreSeguridad
• No haga funcionar este medidor con su caja abierta.
• Antes de abrir la caja, retire la pinza del circuito.
De no observarse estas advertencias pueden sufrirse graves lesiones o incluso la muerte.
• No intente reparar este medidor ya que contiene piezas que deben recibir mantenimiento
por parte de un profesional.
• No exponga el medidor a ambientes de temperatura extrema ni a altos niveles de humedad.
Véase la sección “Especificaciones” en este manual.
De no observarse estas precauciones podrían sufrirse lesiones o daños al medidor.
Peligro de electrocución
• No utilice este medidor si se encuentra mojado o dañado.
• Utilice cables de prueba y accesorios que sean apropiados para la aplicación que se va a
realizar. Consulte la información sobre categoría y voltaje nominal del cable de prueba o el
accesorio.
• Revise minuciosamente los cables de prueba o el accesorio antes de utilizarlos. Deberán
estar limpios y secos, y su forro aislante deberá hallarse en buenas condiciones.
De no observarse estas advertencias pueden sufrirse graves lesiones o incluso la muerte.
Peligro de electrocución
El contacto con circuitos activados puede ocasionar graves lesiones o
incluso la muerte.