GEO Calibration 1000 SP Guide de démarrage rapide

i
Table Contents
Quick Start Guide .......................................................................................................................................... 1
Filling the Water Reservoir ....................................................................................................................... 1
Draining Water for Transportation ........................................................................................................... 3
Cleaning Instructions ................................................................................................................................ 4
Desiccant Installation................................................................................................................................ 5
Desiccant Removal.................................................................................................................................... 6
Refilling the Desiccant............................................................................................................................... 7
Unit Maintenance ..................................................................................................................................... 7
Introduction .................................................................................................................................................. 8
Operational Features .................................................................................................................................... 8
Temperature and Humidity Control ......................................................................................................... 8
Condensation prevention ......................................................................................................................... 8
Front Panel Operation .................................................................................................................................. 9
Main screen............................................................................................................................................... 9
Button Operation .................................................................................................................................... 10
Exit warming mode ................................................................................................................................. 10
Status Lights ............................................................................................................................................ 11
Setting the current temperature and humidity ...................................................................................... 11
Internal Probe Calibration Configuration................................................................................................ 12
Built in Test Heat Exchanger configuration............................................................................................. 12
Built in Test Humidity Generator configuration ..................................................................................... 13
Error List.................................................................................................................................................. 13
GEO 1000 SP Windows application............................................................................................................. 14
Software capabilities............................................................................................................................... 14
Windows Application Installation Guide................................................................................................. 15
Package Contents................................................................................................................................ 15
GEO 1000 SP USB installation ............................................................................................................. 15
Application installation ....................................................................................................................... 15

ii
GEO Windows Application | Usage ........................................................................................................ 16
Main Screen ............................................................................................................................................ 17
Experiments ............................................................................................................................................ 17
Phase....................................................................................................................................................... 18
Modbus Initial setup ............................................................................................................................... 19
Panel Mode ............................................................................................................................................. 20
Plot control.............................................................................................................................................. 21
Reports.................................................................................................................................................... 21
Record Mode........................................................................................................................................... 21
Error codes.................................................................................................................................................. 22
Contact Information.................................................................................................................................... 23

1
Quick Start Guide
Filling the Water Reservoir
Locate the Fill Port
Locate the Fill Tube
Remove Cover from Fill Port
A fill tube is shipping standard with every purchase of a GEO
Calibration calibrator.

2
Gently Connect Tube to Fill Port
Tilt the Unit Forwards
Tilt forwards at a 10 degree angle while filling, to observe fill
level.
Fill the Syringe Reservoir
Only use standard distilled water. Fill one 10 mL syringe at a
time while watching the fill level. The water will naturally flow
into the internal chamber reservoir. Due to the reservoir’s 50
mL capacity, do not fill more than four times in a row.
Un-tilt the Chamber
Once water is observed in the fill level indicator, un-tilt
chamber and fill to slightly less than maximum.

3
Draining Water for Transportation
Place Unit on Edge of Table
Make sure the rear of the unit is over the edge of the table,
with a bucket beneath.
Tilt the Unit Towards Edge
A book or other solid object may be placed under the front of
the unit for stability.
Locate & Remove Drain Cap
The water will immediately begin flowing from the unit into the
bucket below.
**WARNING**
Failure to replace drain cap will result in flooding of the table
top upon refill.
Overfilling of water will flood the chamber. In case of flooded
chamber, you may wipe it out with a standard cloth.

4
Cleaning Instructions
Open the Chamber Door
Unscrew any visible fasteners and pull the door from the
chamber with moderate force.
Clean With Paper Towel
Disinfect with Alcohol Wipes

5
Desiccant Installation
Locate Desiccant Canister
If indicating desiccant was included in your order, you should
check to ensure the desiccant has blue color throughout, with
no pink granules present.
Locate the Two Bungs on Rear
Make sure there are O-Rings inside of each bung.
Push Desiccant into Bungs
Make sure blue desiccant is on the left hand side.
Using gentle force, press the desiccant into the bungs.
Tighten and Attach Velcro Straps
Tightening the Velcro straps will complete the seal.
Make sure the desiccant is properly secured. It should feel and
look “tight,” as shown in the image provided.

6
Desiccant Removal
Unjoin Velcro Straps
Loosen Velcro Straps
Gently Pull Desiccant
Pull with two hands using even force on both sides of the
desiccant canister.
Use thumbs to push out from the chamber body, as shown in
image provided.

7
Refilling the Desiccant
Open Top Cover of Desiccant
Save the spring, the sieve and the three white felt filters.
Discard previous desiccant. Wipe the inside of the desiccant
canister with a clean cloth. Beat filters clean of debris. Clean
the sieve and the spring.
Fill Canister with Desiccant
(Assuming use of approved refill kit)
Insert and push a white filter to the bottom. Empty the
contents of the white desiccant bottle into the canister. Gently
tap to pack. Insert a second white filter. Empty the contents of
the blue desiccant bottle into the canister. Insert one more
filter. Insert one more sieve, followed by the spring. Tighten the
cover.
Unit Maintenance
Daily
Annually
Keep Unit Clean
Control Probe Calibration
Use Proper
Cleaning Materials
Ship unit back for preventative maintenance
annually
Make Sure Water
Level is Maintained
Watch YouTube videos for more information.