9
www.gentecaustralia.com.au
Service inspections at regular intervals especially in high usage areas will assist in
optimising the operational life of the product.
• 2m extension cables are available if
required. The extension can be use
either for the sensor or for the power.
Not for extending both.
3. Connect the water supply to the
solenoid box inlet.
4. Plug in the solenoid box. Make sure
to turn the power first and then the
water flow.
• When the unit is powered on, water
should flow immediately when you put
your hands within range of the sensor.
When you remove your hands out
of range, water should stop within 2
seconds.
The maximum duration of continuous
flow is 1 minute.
BATTERY CHANGE
1. In case you have plugged in the mains,
disconnect power and open the cover
of the control box, open the battery
holder, remove the batteries and
replace all batteries with new ones
2. Please install the batteries in the right
direction, the + and – side are indicated
in the battery holder.
3. Close the battery holder, place the cover
back in place and tighten the screws.
1. Connect the flexible hose from the tap
to the control box outlet. Ensure the
connection is free of any water leak.
2. Connect the tap sensor wires (1m length)
onto the solenoid box matching the cables
by colour.