GE MobileLink CB-1000 Mode d’emploi

T-2 MobileLink Revision D
2002783-060 17 August 2004
127(The information in this manual only applies to the following software versions:
MAC 5000 version 7A.2 or higher;
MUSE 5C: version 005C.10 or higher
5D: version 005D.04 or higher
5E: version 005E.08 or higher
It does not apply to other software versions. Due to continuing product innovation, specifications in this
manual are subject to change without notice.
MAC, MUSE, and MUSE CVare trademarks owned by GE Medical Systems Information Technologies,
a division of General Electric Corporation. All other marks are not owned by GE and are instead owned by
their respective owners.
© 2003-2004, General Electric Company. All rights reserved.

Revision D MobileLink i
2002783-060
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
General Information and Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Customer Responsibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
On-Line Center Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Print the Configuration Capture File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Client Bridge Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Install the Client Bridge on the MAC 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Configure the MAC 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Repeat for Each MAC 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Set Up and Configure the MUSE File Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Using the Serial/IP Tools to Troubleshoot the Connection . . . . . . . . . . . . . . . . . . 29
Field Replaceable Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Original Style Trolley . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
New Style Trolley . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . 34
Client Bridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
PC Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . 34

Revision D MobileLink 1
2002783-060
Introduction
Introduction
This document provides detailed procedures for the installation and
configuration of the software and hardware necessary needed for
wireless transmission of data from the MAC 5000 resting ECG analysis
system to the MUSE CV information system. Once this option is properly
installed and configured, the modem of the MAC 5000 is not used, or
required, in order to transfer and receive data from or to the MUSE
system. To the MAC 5000 user who is transmitting data to the MUSE
system, the functionality of the MobileLink option and the modem option
are the same.
127(
Sending a report from the MUSE system to the MAC 5000 is not
supported by the MobileLink option.
General Information and Guidelines
These are the conventions used in this manual.
Items shown in Bold text are keys on the keyboard, text to be
entered, or hardware items such as buttons or switches on the
equipment.
To perform an operation which appears with a plus (+) sign between
the names of two keys, you press and hold the first key while
pressing the second key once. This is called a keystroke combination.
For example, “Press Ctrl + Esc” means to press and hold down the
Ctrl key while pressing the Esc key.
When instructions are given for typing a precise text string with one
or more spaces, the point where the spacebar must be pressed is
indicated as: [Space]. The purpose of the [ ] brackets is to ensure
you press the spacebar when required.
Enter means to press the “Enter” or “Return” key on the keyboard.
Do not type “enter”.
Italicized items are software terms which identify menu items,
buttons, or options in various windows.
Revision History
Each page of the document has the document part number and revision
letter at the bottom of the page. The revision letter changes each time the
document is updated.
Table 1. Revision History, PN 2002783-060
Revision Date Comment
A 1 February 2003 Initial release of document.
B 9 June 2003 Removed references to access point. Configuration
Capture file changed from “rtf” to “txt” file. Added
information about new MAC 5000 trolley.

2 MobileLink Revision D
2002783-060
Introduction
System Requirements
Before installing the MobileLink option, ensure that the following
requirements are met.
MAC 5000 carts must be at software version 7A.2 or higher.
MUSE CV system must meet one of the following requirements:
5C: 005C.10 or higher,
5D: 005D.04 or higher,
or
5E: 005E.08 or higher
Customer Responsibility
GE Service is responsible for the initial installation and configuration of
the MobileLink wireless communication for ECG. Any changes made to
configuration, security, etc. by the customer after the initial installation
are the responsibility of the customer.
On-Line Center Support
Contact the GE Medical Systems Information Technologies On-Line
Center at 1-800-558-7044 if you have questions or problems while
performing this installation.
C 17 July 2003 Added information about 5D.04 MUSE software.
D 17 August 2004 Added information for turning off firewall software. Added
European FRUs. Added MUSE 5E software.
Table 1. Revision History, PN 2002783-060 (Continued)
Revision Date Comment

Revision D MobileLink 3
2002783-060
Before You Begin
Before You Begin
Print the Configuration Capture File
Be sure all the information about this system has been accurately
entered into the Configuration Capture file (2002783-067). Prior to this
installation, you may have received a copy of this file from Project
Management with information gathered during pre-installation. If so,
use that copy of the Configuration Capture file. If you have not received a
Configuration Capture, you can obtain a blank version of this file on the
MobileLink CD (PN 2015391-001). Print a copy of this file as a reference
to use during the installation. During installation, you will be adding
information to this file and storing the completed file on the MUSE file
server.
127(
Station Name & Port Number have been pre-entered in this file with
the following convention:
127(
The Station Name & Port Numbering system is a suggested
convention.
Configuration Capture file
(2002783-067)providesdataentry
provided for up to 30 MAC 5000
systems. 18B
Station Name Port Number
MAC5K001 3001
MAC5K002 3002
MAC5K003 3003
etc. etc.

4 MobileLink Revision D
2002783-060
Installation Procedures
Installation Procedures
Client Bridge Configuration
127(
As you configure the bridge, be sure that the information is
accurately recorded on the Service Label (one provide with each
client bridge) and that this information matches the information in
the Configuration Capture file (2002783-067) and the information
entered during the configuration. After configuration is done and the
information has been entered on the label, you will be asked to apply
the label to the bottom of the client bridge bracket assembly.
Service Label
1. Connect the client bridge to a computer using a straight through
network cable. Plug in the AC adapter for power.
127(
In order for the symbolst.exe application to work properly, the
computer must be connected ONLY to the client bridge. Any
other network communications will cause errors with the
application.
If the computer is unable to access the client bridge, see
“Troubleshooting” on page 27 for a suggested remedy.
2. Insert the MobileLink CD.
3. Execute the SymbolStationManager program by double-clicking the
symbolst.exe file.
13A

Revision D MobileLink 5
2002783-060
Installation Procedures
The CB-1000 Unit List window appears.
4. Select the device identified on the top line and click Configure.
The startup screen for the configuration tool appears.
01B
02A

6 MobileLink Revision D
2002783-060
Installation Procedures
5. Select the Network tab on the left side.
Enter the IP Address of the MAC 5000 client bridge and the
associated Netmask for this network segment.
127(
The Gateway address is only needed if the MAC 5000 will be on a
different subnet than the MUSE file server.
6. Select the Serial tab on the left side and then select the UART tab
from the top row of tabs.
7. Select/verify the following in the UART tab:
Baud 115200
Data bits 8 bits
Stop bits 1bit
Parity none
03A
04A
Table des matières
Autres manuels GE Système de conférence
Manuels Système de conférence populaires d'autres marques

Kramer
Kramer VIA GO Manuel utilisateur

AVT
AVT MAGIC AC1 Go Manuel utilisateur

ProSoft Technology
ProSoft Technology AN-X4-AB-DHRIO Manuel utilisateur

Sony
Sony PCS-I150 Manuel utilisateur

Middle Atlantic Products
Middle Atlantic Products VTC Series Manuel utilisateur

Prentke Romich Company
Prentke Romich Company Vanguard Plus Mode d’emploi