I. Overview
1.1 About this manual
This manual provides how to use the ZXPD-200L partial discharge
detector in a safe way. Before you use this product for the first time, please read
the instruction manual carefully, which will help you to use this product skillfully.
The instruction manual details the operation methods of the safety regulations
and the flow of using various measurement modes.
1.2 Liability statement
The company guarantees that each product has no quality problems in the host
and accessories when it leaves the factory, and that there is no defect in the
function of the host. The warranty period of the ZXPD-200L partial discharge
detector is one year, and the warranty period starts from the date of shipment.
Provide free repair services for products within the warranty period, and
guarantee that the repair period does not exceed 90 days. If the user damages
the product due to misuse, disassembly, negligence, accident, or abnormal
operation during use, the company will not provide any free maintenance
service.
When maintenance service is required, please contact the service center of our
company nearby. The service center will choose whether to provide door-to-door
pickup service according to your area. When the door-to-door pickup is not
available, the service center will negotiate with you whether to send the product

3
to the service center by mail. After the repair is completed, the service center will
contact you to negotiate the appropriate way to return the product. If the
company determines that the failure is due to misuse, disassembly, accident,
abnormal operation, or the product has passed the warranty period, the
company will estimate the repair cost and start repairs only after obtaining user
authorization. For users who pay for repairs, they will receive invoices for repairs
and return shipping costs at the same time they receive the repaired products.
This statement contains all the maintenance contents provided by our company,
and our company does not provide maintenance services expressed or implied
in other ways. At the same time, the company will not be responsible for any
special, indirect, accidental damage and data loss, regardless of whether it will
cause economic and civil losses to users. The right to use this manual is limited
to users of this company. Without any written permission of the company, it is
strictly prohibited to copy, transmit, distribute and store any content in this
document in any form.
2. Product Introduction
2.1 Notes
The ZXPD-200L partial discharge detector is used for the detection and
evaluation of the insulation status of high-voltage switchgear, ring network
cabinets, transformers, GIS, overhead lines, cable terminals, cable branch

4
boxes and other equipment. There are the following precautions when using this
device:
☀Please use indoors with a temperature of -20 ℃ ~ 50 ℃and a relative
humidity not exceeding 80%;
☀Please stay away from flammable and explosive dangerous goods;
☀Please charge the instrument when it is powered on for the first time, and only
turn on when the charging indicator is on;
☀To prevent interference or leakage, please turn off the power switch when
charging;
☀If the liquid and corrosive substances come into contact with the instrument, it
should be immediately stopped and shut down, and handled by a professional;
☀All connectors are imported connectors, and they should be plugged in and
out. Do not rotate, shake the connector, or pull the cable forcefully. The plug
connector is moderately strong and should be inserted into place when plugged
☀All mainframes and accessories must not be disassembled. If it is really
necessary, it needs to be disassembled by our after-sales service personnel.
2.2 Brief description
The ZXPD-200L partial discharge detector can be widely used in the theater
detection of power systems, including the insulation status of high-voltage
switchgears, ring network cabinets, voltage / current transformers, transformers
(including dry-type transformers), GIS, overhead lines, and cables Detection, to

5
measure the discharge level of electrical equipment through the following
indicators:
Partial discharge intensity detection: By measuring the discharge signal within a
power frequency period, the intensity of partial discharge is characterized
according to the maximum value (dB) in the discharge pulse sequence.
Partial discharge frequency detection: The device measures the discharge
signal within a power frequency period, extracts discharge pulses and
characterizes the frequency of partial discharges according to the number of
discharge pulses.
2.3 Product features
☀Configure different sensors to realize partial discharge detection of almost all
electrical equipment;
☀Provide time domain waveform, PRPD, PRPS and other discharge patterns to
realize the analysis of different discharge types;
☀Humanized man-machine interface facilitates data management of different
devices, including traceback of historical data change trends, horizontal and
vertical data analysis, and realizes 360 ° comprehensive diagnosis of the device
under test;
☀Built-in ultrasonic sensors and transient ground voltage (hereinafter referred
to as TEV) sensors, which can be connected with special sensors such as
transformers, GIS, overhead lines and cables;

6
☀Adopt non-intrusive detection method, no power failure during the test, maybe
no high voltage source is applied, which is more convenient to use than
traditional pulsed partial discharge detector;
☀The test bandwidth range is 30kHz ~ 2.0GHz, suitable for the detection
principle of various frequency bands;
2.4 Product Application
ZXPD-200L partial discharge detector is widely used in the following fields:
☀Development and distribution enterprises
☀Railway system
☀Petrochemical power supply system
☀Aerospace testing field
☀Automatic testing field
2.5 Parameters
TEV measurement
UHF measurement
Measuring range
0-60 dBmV
detection frequency
300-1500MHz
Resolution
1dB
measurement range
-75dBm-0dBm
Accuracy
±1dB
accuracy
<1dBmV
Maximum pulse per
cycle
1400
Sensor band
300-2000MHz
Measurement
frequency band
1~100MHz
AA measurement
AE measurement
Measuring range
-6dBμV - 68dBμV
Measuring range
-6dBμV - 68dBμV
Resolution
1dB
Resolution
1dB
Accuracy
±1dB
Accuracy
±1dB
Sensor center
frequency
40 kHz
Frequency range
40~200 kHz
HFCT measurement
Sensor
transmission
impedance
5mV/mA
Detection frequency
1~30MHz
Sensitivity
≤50pC
hardware

7
Shell
ABS
Display
4.0 inch RGB LCD screen
Controller
ARM
Connector
USB interface (also charger input)
3.5mm stereo headphone jack
External ultrasonic sensor input
wireless wifi
Wireless synchronization benchmark
Earphone
minimum 8 ohm
SD card
standard 16G
Built-in battery
3.7V/1Ah lithium battery
Working time
about 8 hours
Charger
AC 90-264V or DC 5V
Operating temperature
-20 ~ 50℃
Humidity
20-85% relative humidity
Weight
0.4KG(host)
2.6 Standard
DL / T 500-2009 Technical conditions for voltage tester
GB / T 4208-2008 Classification of enclosure protection level (IP code)
GB / T 2423.1-2001 Basic environmental test regulations for electrical and
electronic products Test A: Low temperature test method
GB / T 2423.2-2001 Basic environmental test regulations for electrical and
electronic products Test B: High temperature test method
GB / T 2423.4-1993 Basic environmental test regulations for electrical and
electronic products Test: alternating damp heat test method
GB / T 2423.5-1995 Environmental testing for electrical and electronic products
Part 2: Test methods Tests and guidelines: Impact test methods
GB / T 2423.10-1995 Environmental testing for electrical and electronic products
Part 2: Test methods Tests and guidelines: Vibration (sine) test method
GB / T 17626.2-2006 Electromagnetic compatibility test and measurement
technology Electrostatic discharge immunity test (IEC 61000-4-2: 1995)

8
GB / T 17626.5-2008 Electromagnetic compatibility Test and measurement
technology Surge (shock) immunity test (IEC 61000-4-5: 1995)
GB / T 17626.3-2006 Electromagnetic Compatibility Test and Measurement
Technology Radio Frequency Electromagnetic Field Radiation Immunity Test
(IEC 61000-4-3: 1995)
GB / T 17626.4-2008 Electromagnetic Compatibility Test and Measurement
Technology Fast Transient Electrical Pulse Group Immunity Test (IEC 61000-4-4:
1995)
GB / T 17626.7-1998 Electromagnetic compatibility Test and measurement
technology Power supply system and connected equipment Harmonic and
interharmonic wave measurement and measurement instrument guide
GB / T 19862-2005 Industrial automation instrument insulation resistance,
insulation strength technical requirements and test methods
2.7 Product configuration list
The ZXPD-200L partial discharge detector is composed of the detection host,
sensor, PC, software CD and related accessories. Among them, the sensor, PC
and software CD are optional parts.Shown as Table 1
Name
Model
Quantity
Unit
Remarks
1
Detection host
ZXPD-200L
1
set
standard
2
External contact ultrasonic sensor
GAE-40
1
pcs
optional for partial discharge
detection of transformers,
GIS, motors, etc
3
UHF sensor
GUHF-2
1
pcs
option for GIS partial
discharge detection
4
High frequency transformer
GCT-3
1
pcs
1 option for cable partial
discharge detection
5
test leads
-
1
set
standard

9
6
charger
-
1
pcs
standard
7
USB cable
-
1
pcs
charging and PC data
communication
8
Use manual
-
1
copy
9
Factory inspection report
-
1
copy
10
Certificate
-
1
copy
11
Warranty card
-
1
copy
Table 1
This manual demonstrates that the device language is Chinese, and it can
be completely set to English when overseas customers purchase
3. Operating Instructions
3.1 Structure
ZXPD-200L Host
The front end of the ZXPD-200L host has a built-in non-contact ultrasonic sensor
and a built-in TEV sensor, which can realize the detection of partial discharge of

10
high and low voltage switch cabinets without external sensors. For the detection
of partial discharge of equipment such as cable terminals and cable branch
boxes, it is only necessary to connect the corresponding special sensor through
the sensor expansion port at the bottom of the host. The host can automatically
switch the measurement mode according to the different sensors. For sensors
that can be connected to ZXPD-200L, please refer to the optional part in Table 1
of the product configuration list.
3.2 System power on and off and status display
Power button
ZXPD-200L realizes the switch on and off by touch switch, only need to touch on
the power label, the status indicator will show the current working status of the
host after power on, if the power adapter is connected, and the indicator C Lights
up until the battery is fully charged.
The indicator S is used to show the status of data sampling or online status. In
normal measurement mode, the S status indicator flashes red, and when the
host is online (connected with PC) and the PC is successfully connected, the S
status indicator flashes green .
Indicator light
3.3 Test
3.3.1 Test with built-in sensor
There are two principles for the partial discharge detection of the switchgear: the
Table des matières