Page 5
828 Manual
SET CLOCK+SHIFT button: Set the on board real time clock.
Use the up and down buttons to change the highlighted time/
date, and the sideways buttons to select which item to set. Use
the ENTER button to save the time and date shown, and exit the
menu. To exit the menu without saving, use the ESC button.
SET PTO POLARITY+SHIFT button: Select whether the PTO is
active when high or low polarity is present on the PTO wire. Use
the up and down buttons to change the selection. Use the ENTER
button to save the value shown, and exit the menu. To exit the
menu without saving, use the ESC button.
SET PTO PULLUP+SHIFT button: Select whether the PTO pull-up
is on or off. Use the up and down buttons to change the selection.
Use the ENTER button to save the value shown, and exit the menu.
To exit the menu without saving, use the ESC button.
SET PTO DELAY+SHIFT button: Sets the delay after the PTO is
engaged or disengaged before a serial data transmit is done. Use
the up and down buttons to change the value shown. Use the
sideways buttons to select the engage or disengage delay. Use
the ENTER button to save the value shown, “st” will be shown for a
couple of seconds to verify that the value has been stored. Once
the new values have been stored, use the ESC button to exit the
menu. Any changes made after pressing the ENTER button will
not be stored.
VERSION+SHIFT button: Shows the hardware and software
version of the 828.
SET NO. TANKS+SHIFT button: Set the number of compartments
to be monitored and displayed on the LCD screen for updates. This
should match the number of SEELEVEL™ gauges. Use the up and
down buttons to change the value shown. Use the ENTER button
to save the value shown, and exit the menu. To exit the menu
without saving, use the ESC button. Currently, 806 gauges can
only monitor compartment one. The 806 gauge must be viewing
compartment one to work.
SET TX INTERVAL+SHIFT button: Sets the interval between
automatic serial data transmissions of the levels shown on the
display. This can be from 1 to 99,999 seconds. Use the up and
down buttons to change the highlighted digit. Use the sideways
buttons to select a different digit. Use the ENTER button to save
the value shown, and exit the menu. To exit the menu without
saving, use the ESC button.