General information
The 3G-COM-G communicator is designed to report events through an
Internet connection across three communication channels:
1) Internet connection through a WiFi network
2) Internet connection using a mobile data service
3) Text message transmission using a cell phone service
The communicator prioritizes communications through a WiFi connec-
tion. Therefore, the mobile phone data connection or transmission is
used as support in case of a failure or absence of connection of the WiFi
network.
Technical specications:
WiFi:
• Transmission: Certied WiFi 2.4Ghz, IEEE 802.11.
• Certicate FCC/CE-RED/IC/TELEC/KCC/SRRC/NCC
• Transmit power: 20,5 dBm.
• Wi-Fi authentication via WEP, WPA-PSK and WPA2-PSK.
• Antenna: PCB trace type.
3G UMTS/HSDPA
• Transmission: GSM, GPRS / SMS.
• Automatic quad-band: 850/1900MHz UMTS
850/900/1800/1900MHz GSM
• Carriers settings: Automatic.
• 110dBm @UMTS Bands -108.5dBm @GSM 900MHz -108.5dBm @GSM 1800MHz
General specications
• Double communication channel WiFi and 3G UMTS/HSDPA.
• Compatible with PC-732G / A2K4-NG / A2K8.
• 1 mobile network receiver and 1 WiFi receiver for monitoring reports
• Allows own and panel programming with AC4 software
• Allows App programming in AP mode from Garnet Programmer
• Reports in residential format (event restriction).
• Allows the use of domain names instead of IP addresses.
• Connection with dedicated Bus (BUS-C485).
• Allows the remote system operation with smartphones using the
Garnet Control App.
• Up to 20 residential users.
• Report communication using UDP.
• WiFi monitoring period congurable from 1 to 99 minutes.

3
• 3G monitoring period congurable from 1 to 9999 minutes.
• Two Garnet reporting formats: DC1 and SDC2.
• 9 board status and signal Led indicators.
• No self powered battery, it shares the battery with the alarm panel.
• Nominal input voltage: 12VCC (9 to 14VCC).
• Consumption: 90 ~ 135 mA
Module description:
Communication formats:
The 3G-COM-G Alarm Communicator is designed to send alarm signals
to monitoring receivers that receive events under DC1 and SDC2 com-
munication protocols.
Panel control methods:
The 3G-COM-G Communicator allows panel control with two methods:
the use of the Garnet Control App and text or SMS messaging.
Compatible panels:
The 3G-COM-G Communicator is compatible with Garnet and DSC panel
families.
For Garnet panels, the communicator shall be installed in the keypad
data bus (See gure 2).
Garnet compatible panel models:
PC-732G / A2K4-NG / A2K8
DSC compatible panel models:
PC585, PC1565, PC832, PC1832, PC5015

4
Connections:
Figure 1 –BUS-C485 mode of operation:
+ A B Y G-
SIM-1
ANTENA
WIFI
SIGNAL 1-5
NO SIGNAL
ANTENA
3G
COMUNIC
WIFI
COMUNIC
3G
SIM-2
ACK
NAK
- AUX + + BELL - A B
PGM1 PGM2
Z1 Z6CZ5Z4CZ3Z2C R1 TIP
RING
T1
AC + BAT - A B+ AUX -

5
Figure 2 – DSC mode of operation:
+ A B Y G-
SIM-1
ANTENA
WIFI
SIGNAL 1-5
NO SIGNAL
ANTENA
3G
COMUNIC
WIFI
COMUNIC
3G
SIM-2
ACK
NAK
AC - AUX + + BELL - 1 PGM 2
KEY PAD
YEL GRN Z1 Z2
COM Z3 Z4
COM RNG T-1 EGND
R-1
TIP
PANEL DSC

6
Status led indicators
The 3G-COM-G Communicator has a variety of leds that report dierent
status of the communicator.
These include leds to indicate WiFi network signal strength, 3G network
signal strength, server report results and monitoring station report
results.
Explanation of led indicators
There are two groups of leds, those that indicate the WiFi or 3G network
connection signal strength and those that indicate the results of WiFi
and 3G network data communications.
WiFi signal or 3G network led indicators
These leds indicate if the communicator is connected to a network.
If the communicator is connected to a WiFi network, the blue Led, that
represents the WiFi Antenna, shall indicate the strength by blinking
according to its signal level.
The number of ashes represents the signal level, 1 ash indicates a low
signal level and 5 ashes indicate maximum signal level.
If the communicator is not connected to a WiFi network, the red led “No
Signal” shall be on indicating that the communicator is not connected to
a WiFi network.
The 3G antenna instructions are the same as the above.
Antena Wi Antena 3G Comunic Wi Comunic 3G
Signal 1-5
No Signal
ACK
NAK

7
Communication Led indicators
The communicator is prepared to communicate through WiFi and
mobile data. In both cases, in the event there is a communication or
some kind of report, the result will be indicated through leds represen-
ting such communications.
In case of a report to the monitoring station or in residential format,
the result shall be represented through two leds, one representing a
successful report (ACK) or another indicating a failure in communication
(NAK).
When the communicator reports supervision to monitoring or to server
XXX, both leds will turn on simultaneously.
“Status” led
This led indicates the work mode according to the ashing speed.
If the led ashes slowly (1 second interval) it means that it is congured
to work in “DSC” mode, if the ashing is rapid (10 times per second) it
means that it is congured to work in the BUS-C485T.
“NET” Led
This led indicates the status of the mobile data network.
Status Description
200mS on / 1800 mS o Network search
1800 mS on / 200 mS o Idle
125 mS on / 125 mS o Transriendo datos

8
Communicator / Alarm panels programming
Alarm panel programming:
To congure the Garnet alarm panels through the communicator, the
communicator shall previously be activated in the panels. To that end,
follow the steps below in the panel programming section:
With Keypad G-LCD732 / G-LCD732RF / KPD-860 / KPD-860RF
1) Enter Tool key + [5] + [INSTALLER CODE]
2) Program the command [299] with the following Values [xxxx11xx]
With Keypad G-LED732 / KPD-800
1) Enter *8 + [5] + [INSTALLER CODE]
2) Program the command [299] with the following Values [xxxx11xx]
NOTE: The DSC panels cannot be programmed through the communi-
cator and the conguration App.
Programming the communicator and the panel using
the Garnet Programmer app
The communicator shall be programmed through the “Garnet
Programmer” app. This app also allows the programming of Garnet
alarms panels.
To download the app please scan the following QR codes or search the
Garnet Programmer app in your download store.
Android
Click here
iOs (iPhone)
Click here

9
Follow the steps below:
1) Press the “AP ENABLE” button on the board.
This will cause the communicator to generate a WiFi network during a 5
minute period.
2) Search for available WiFi networks in your phone and connect to the
WiFi network named “3G-COM-Gxxxxxx”. The numbers XXXXXX are the
last 6 digits of the communicator mac.
3) Enter the default network password: admin1234.
4) Once the communicator enters the programming mode, the leds will
behave as follows
In case this result is not obtained, repeat the steps above. The cell
phone shall be in “Flight” mode when connecting to the module WiFi
network.
5) Once ready, open the Garnet Programmer app and follow the
instructions you wish to program.
Note: During communicator programming inside the “status” display,
you shall take note of the System Number since it will be used in the
next step
Activation of Telephones or Terminals
To activate telephones you shall rst make sure that the communicator
has been previously congured and has a successful WiFi or mobile data
Internet connection.
Antena Wi Antena 3G Comunic Wi Comunic 3G
Signal 1-5
No Signal
ACK
NAK

10
From you phone store download the User “Garnet Control” app.
Once the app is downloaded, you shall register with your personal data.
Once inside the app, press the button “+” to add a new system, enter
the System Number obtained in the previous step, enter a name to
identify the alarm system being installed and, nally, enter an icon.
Then you shall initiate the connection with your phone from the com-
municator.
Press 3 times the button “AP ENABLED” or, if you have an LCD keypad,
press [ ] + 8 + 7.
The conrmation of successful activation will be indicated with the
blink of the 4 upper leds that indicate antennas and communications.
Following press the button “Verify” on your cell phone.
Your app will be ready to be used in a few seconds.
Note: The Garnet Control app allows the addition of up to 20 users.
The main user will be the “Administrator”. The Administrator may invite
the remaining 19 users of the system in two dierent user categories:
• Main User:
This user may be dened by the administrator in terms of the functions
and permits held regarding the alarm panel.
Android
Click here
iOs (iPhone)
Click here
Table des matières
Autres manuels Garnet Téléphone portable