Furuno DS-80 Manuel utilisateur

DOPPLER SPEED LOG
DS-80
Marine Speed and Distance Measuring Equipment (SDME)

Your Local Agent/DealerYour Local Agent/Dealer
9-52 Ashihara-cho,9-52 Ashihara-cho,
Nishinomi
y
a, Ja
p
anNishinomi
y
a, Ja
p
an
Tele
p
hone :Tele
p
hone : 0798-65-21110798-65-2111
Telefax :Telefax : 0798-65-42000798-65-4200
F
IRST EDITION :
F
IRST EDITION : FEB.FEB. 20002000
Printed in JapanPrinted in Japan
A
ll ri
g
hts reserved.
A
ll ri
g
hts reserved. MM :: FEB.FEB. 12,200212,2002
PUB.No.PUB.No. IME-72470-MIME-72470-M
*00080889800**00080889800*
*00080889800**00080889800*
(( TATATATA )) DS-80DS-80 * 0 0 0 8 0 8 8 9 8 0 0 ** 0 0 0 8 0 8 8 9 8 0 0 *
*IME72470M00**IME72470M00*
*IME72470M00**IME72470M00*
* I M E 7 2 4 7 0 M 0 ** I M E 7 2 4 7 0 M 0 *

i
SAFETY INSTRUCTIONS
CAUTION
Confirm that the power supply voltage
is compatible with the voltage rating
of the equipment.
Connection to the wrong power supply
can cause fire or equipment damage. The
voltage rating appears on the label at the
rear of the display unit.
Ground the equipment.
Ungrounded equipment can give off or
receive electromagnetic interference or
cause electrical shock.
Keep the following compass safe
distances.
WARNING
Only qualified personnel
should work inside the
equipment.
This equipment uses high
voltage electricity which can
shock, burn, or cause serious
injury.
Turn off the power at the
mains switchboard before
beginning the installation.
Post a sign near the switch
to indicate it should not be
turned on while the equip-
ment is being installed.
Fire, electrical shock or
serious injury can result if the
power is left on or is applied
while the equipment is being
installed.
Display Unit
Digital Indicator
Distance Indicator
Distribution Box 3.10 m 2.10m
Transceiver Unit 2.05 m 1.40 m
Terminal Box 0.65 m 0.45 m
Standard Steering
0.50 m 0.40 m
Careful consideration is required to avoid
ingress of water through the transducer
tank. The tank shall be strong enough to
withstand the water pressure in fully loaded
conditions in rough weathers. FURUNO
Electric Co., Ltd. is not liable to any loss of
ship and personnel which is caused by in-
stallation procedures.

ii
TABLE OF CONTENTS
SYSTEM CONFIGURATION ................. iii
EQUIPMENT LISTS .............................. iv
1. MOUNTING ........................................ 1
1.1 Category of Equipment ...........................1
1.2 Display Unit ............................................2
1.3 Transceiver Unit......................................3
1.4 Transducer Unit ......................................4
1.5 Distribution Box ....................................12
1.6 Terminal Box (option)............................13
1.7 Digital Indicator, Distance Indicator
(option)................................................13
1.8 Junction Box (option)............................14
1.9 Dimmer (option)....................................15
1.10 Range Switch Box, Analog Display Unit
(option)................................................15
2. WIRING ............................................ 16
2.1 Precautions for cable Installation...........16
2.2 Wiring of Distribution Box......................17
2.3 Wiring of Transceiver Unit.....................21
2.4 Wiring of Terminal Box ..........................23
2.5 Display Unit (Digital Indicator, Distance
Indicator) ............................................ 24
2.6 Dimmer, Analog Display Unit, Range
Switch Box.......................................... 24
2.7 Grounding............................................ 25
2.8 Wiring Check ....................................... 25
3. SYSTEM SETTINGS ........................ 26
3.1 Transducer Adjustment ........................ 26
3.2 Setting of System Menu 2 .................... 27
3.3 Checking the Interconnection............... 28
3.4 Setting of the Maximum Speed Range . 29
3.5 Ship's Speed Adjustment...................... 29
3.6 Setting for Analog Display .................... 30
3.7 DIP Switch S4 Settings ........................ 31
4. CHANGING AC POWER TAP .......... 33
APPENDIX CALIBRATION ..............AP-1
PACKING LISTS................................. A-1
OUTLINE DRAWINGS........................ D-1
INTERCONNECTION DIAGRAMS..... S-1

iii
SYSTEM CONFIGURATION
TRANSDUCER
DS-820
DISPLAY UNIT
DS-800
IEC 61162-1 Input
(Navigational equipment, GGA, VTG, VBW)
Power ON SW Signal
Distance Run Signal
IEC 61162-1 Output
DIGITAL INDICATOR DS-830
DISTANCE INDICATOR DS-840
: STANDARD SUPPLY
: OPTIONAL SUPPLY
DISTRIBUTION BOX
DS-801
TRANSCEIVER
UNIT DS-810
DIMMER MF-22L-1/MF-22L-2
TERMINAL BOX
DS-802
TERMINAL BOX
DS-802
DIMMER MF22L-1/MF22-2
SHIP'S MAINS
115 VAC or 230 VAC
1φ, 50/60 Hz
RANGE SWITCH BOX
DS-389
DIMMER MF-22L-1/MF-22-2
ANALOG DISPLAY
MF-22A-1
115 VAC or
230 VAC
JUNCTION BOX
CI-630
: LOCAL SUPPLY

iv
EQUIPMENT LISTS
Standard supply
Name Type Code No. Qty Remarks
Display Unit DS-800 - 1
DS-801-100 - 100 VAC
DS-801-110 - 110 VAC
DS-801-115 - 115 VAC
DS-801-200 - 200 VAC
DS-801-220 - 220 VAC
Distribution Box
DS-801-230 -
1
230 VAC
Transceiver Unit DS-810 - 1
Transducer Unit DS-820 - 1 with 10/20/30m cable
Terminal Box DS-802 - 1
Spare Parts SP65-00700 000-029-046 1 set
w/SP65-00701,
SP65-00702, SP65-00601
Installation
Materials CP65-00900 000-029-047 1 set
w/CP65-00901,
CP65-00902, CP65-903
Optional equipment
Digital Indicator (000-029-020)
Name Type Code No. Qty Remarks
Digital Indicator DS-830 - 1
Spare Parts SP65-00601 002-889-730 1 set Fuse
Accessories FP65-00400 000-029-028 1 set FP65-00401, FP65-00402,
FP65-00403
Installation
Materials CP65-00800 000-029-027 1 set
CP65-00801,
MJ-A7SPF-005-020,
MJ-A6SPF-003-020
Remote Distance Indicator (000-029-022)
Name Type Code No. Qty Remarks
Distance Indicator DS-840 - 1
Spare Parts SP65-00601 002-889-730 1 set Fuse
Accessories FP65-00400 000-029-028 1 set FP65-00401, FP65-00402,
FP65-00403
Installation
Materials CP65-00800 000-029-027 1 set
CP65-00801,
MJ-A7SPF-005-020,
MJ-A6SPF-003-020

v
Optional equipment
Name Type Code No. Qty Remarks
Terminal Box DS-802 000-029-048 1 set w/CP65-00903
DS-389 000-028-039 1 set w/CP66-01000
MF-22R-1 000-069-391 1 set Flush mount type
Range Switch Box
MF-22R-2 000-069-392 1 set Bulkhead type
MF22L-1-100V 000-069-401 1 set flush mount
MF22L-1-200V 000-069-402 1 set flush mount
MF22L-2-100V 000-069-403 1 set bulkhead
Dimmer
MF22L-2-200V 000-069-404 1 set bulkhead
Junction Box CI-630 - 1 set w/CP66-00703
DS-850 000-029-050 1 set w/tightening handle
DS-781 000-029-051 1 set
Projection type
Through-hull Pipe [TFB-5000
(1)]
DS-782 000-029-052 1 set Gate valve, projection type
DS-784 000-029-054 1 set Flush type
Seachest
DS-786 000-029-055 1 set Gate valve type
Analog Display MF22A-1 000-069-381 1 set -10 to +30 knots, compact type

This page is intentionally left blank.

1
1 MOUNTING
1.1 Category of Equipment
Equipment for protected area
• Display Unit
• Distribution Box
• Transceiver Unit
• Terminal Box (one standard, other optional)
• Digital Indicator (option)
• Distance Indicator (option)
• Range Switch Box (option)
• Dimmer (option)
• Junction Box (option)
• Analog Display (option)
Equipment to be submerged
• Transducer

2
1.2 Display Unit
1.2.1 Mounting considerations
The display unit can be installed on a tabletop, on the overhead, on the bulkhead or flush
mounted in a console or panel.
When selecting a mounting location for the display unit keep the following in mind.
• Keep the display unit out of direct sunlight.
• The temperature and humidity of the mounting location should be moderate and stable.
• Locate the unit away from exhaust pipes and vents.
• Keep the unit away from electromagnetic field-generating equipment such as motors and
generators.
• For maintenance and checking purposes, leave sufficient space at the sides and rear of the
unit and leave slack in cables.
• A magnetic compass will be affected if the display unit is too close to it. Observe the
compass safe distances to prevent disturbance to the magnetic compass.
Tabletop Overhead
Display unit, tabletop and overhead mounting method
1.2.3 Mounting procedure (tabletop, overhead)
1. Fix the hanger with four tapping screws (M5x20).
2. Screw knob bolts in display unit, set it to hanger, and tighten knob bolts.
1.2.4 Flush mounting
There are two types of flush mount kits, F type and S type. For details, see the outline diagrams
at the back of this manual.
Autres manuels pour DS-80
2
Table des matières
Autres manuels Furuno Équipement nautique

Furuno
Furuno FELCOM 250 Manuel utilisateur

Furuno
Furuno GS-100 Manuel utilisateur

Furuno
Furuno GP-1870F Manuel utilisateur

Furuno
Furuno GP-1640F Manuel utilisateur

Furuno
Furuno LH-3000 Manuel utilisateur

Furuno
Furuno TZTL12F Manuel utilisateur

Furuno
Furuno FCV-38 Manuel utilisateur

Furuno
Furuno FELCOM 250 Manuel utilisateur
Manuels Équipement nautique populaires d'autres marques

Dowco
Dowco V322 CC - 2019 Manuel utilisateur

Humphree
Humphree HCS-5 Manuel utilisateur

Vetus
Vetus BOW4512D Fiche technique

Dock Doctors
Dock Doctors SLIDING BOARDING STEP Manuel utilisateur

Mastervolt
Mastervolt Mass Combi 12/2000-100 Instructions d'utilisation d'origine

Zattini Group
Zattini Group bamar BOXTRON E14S Guide de l'utilisateur











