Fulcrum DRX-4C Manuel utilisateur

DRX-4C
Instruction Manual Model
Fulcrum Inc.
23 Carol Street.
Clifton, NJ 07014
(973) 473-6900
(973) 777-8302
http://www.fulcruminc.net


TABLE OF CONTENTS
0
0
0
0
0
0
0
0
0
1. Specifications..........................................................................1
2. Parts Description .....................................................................2
3. Keys and display indicators .........................................................3
4. Commands .............................................................................4
5. Getting Started ........................................................................5
6. Weighing................................................................................ 7
7. Zeroing the scale ......................................................................8
8. Taring ....................................................................................9
9. Clearing the Tare ....................................................................11
10. Compounding (Recipe Making) ..................................................12
11. Printing the Recipe .................................................................14
12. Pill Counting (Counting prescription drugs for the first time.) .............15
13. Pill Counting (Counting prescription drugs which
have been previously stored in the scale's database.) .......................20
14. NDC Verification .....................................................................23
15. Printing a pill count receipt ........................................................25
16. Maintaining and modifying the database ......................................26
17. Calibration ............................................................................29
18. Sealing the DRX-4C .................................................................32
19. Setting the Time and Date...... ...................................................34
20. Common Errors and Troubleshooting ..........................................38

Instruction Manual
a
Important handling Cautions and Warnings
Always handle your scale with care.
Damage caused by improper handling is not covered under the scale’s warranty.
Never drop or throw any
articles onto the scale’s pan
or onto any other parts of the
unit!
DO NOT let the scale fall or
drop from its tabletop
surface!
When moving the scale do
not press or apply force onto
the scales pan!
DO NOT pass or handle
liquids directly over the
scale to avoid spillage and
liquid damage!

Instruction Manual
C
CAUTIONARY NOTES AND PRECAUTIONS
The TORBAL Precision scale is a sensitive and a delicate instrument. Always handle your scale with care.
The correct location and proper environment affect the accuracy of your TORBAL Precision Scale.
The best location for your scale:
1.Stable, horizontal, vibration-free surface
2.Away from direct sunlight
3. ot exposed to high temperature variations
4.Away from direct drafts
5.The best location is on a stable bench away from drafts, doors, windows, radiators and air
conditioner vents.
CAUTION:
oThe scale is designed for indoor use only.
oDo not operate the scale in hazardous areas or under dangerous conditions.
oDo not use the scale in locations subject to high humidity or dust levels.
oDo not connect cables in ways other than those mentioned in this manual.
oSet the scale on a firm, stable, horizontal surface.
oever stand on or lean on this product. Equipment may fall or collapse, causing
breakage and possible injury.
oBefore moving the product, unplug it and unplug all cables connected to it.
oWhen storing, transporting or returning the scale for service, use the original
packaging.
WARNING:
a. ever attempt to repair, disassemble or modify the scale. Tampering with the scale
may result in injury and cause greater damage to the equipment.
b. Never swap the pan, pan base, or any other parts of the scale with pans or parts from
other units. Pans and all components are uniquely assigned to each unit.
c. Be sure to use the specified power source.
d. Do not allow foreign matter to fall into the scale.
e. If water or other liquids spill into the scale, unplug the power cord immediately and
contact technical support
TORBAL Precision scale is a sensitive and a delicate instrument. Always handle your
scale with care.
3

Instruction Manual Model DRX-4C
Specifications:
1
Specifications:
CHAPTER 1

Parts Description:
2
Front View Rear View
Scanner Stand Scanner Pan Base Pan
Adjustable Legs
Seal Screws AC Adaptor socket
RS232 Serial Port
Calibration Switch Level Indicator
Instruction Manual Model DRX-4C
Scanner Cable RJ Connector
(Plugs into
the scanner)
Rs232
(Plugs into
the scale)
AC Adaptor
CHAPTER 2

Keys and display indicators
3
Center of zero NET result indicator
Stabilization indicator Used Capacity Indicator
*To enter the calibration mode, the rear calibration switch must be toggled to the "ON" position.
**For the scale to enter and remain in the standby mode, the power supply must be plugged into
the scale.
NOTE:
Tare button used to tare the weighing pan and to enter or accept
commands.
Function button used to swap between the weighing and counting
modes.
Power On/Off button - when turned "Off", the scale enters the
standby mode. **
Scale stabilization indicator - signals the weighing result has
stabilized and an accurate reading may be taken.
Indicates the Auto Zeroing Setting Mechanism (AZSM) is active.
AZSM automatically maintains a "center of zero" condition within
+/- .6d (6mg)
Weighing unit, in grams
Print button, used to print or send data to a PC.
Zero button, used to re-zero the scale.
Instruction Manual Model DRX-4C
Total and sum
Clear and Cancel key - Used to cancel compounding and counting
operations.
C
Dotted line on the display - indicates the T or buttons have been
pressed and the scale is taring or re-zeroing.
SUM key used to verify the total recipe weight in the compounding
function.
CHAPTER 3

Indicates to scan the NDC code. **
The scale failed to find a match between NDC codes in the
NDC Verification feature. **
Commands
4
*These commands apply to the calibration mode only.
**These commands apply to the counting mode only.
NOTE:
When the P button is pressed, "PRINT" indicates data is
printing via the Serial port.
Indicates the rear calibration switch has been toggled to
the "ON" position and the scale is in the calibration mode.*
Indicates the scale is taring for the calibration procedure
to begin.*
Indicates to load the calibration weight of 300 grams on
the pan in order to begin calibration.*
The scale is calibrating.*
Calibration procedure is finished.*
Instruction Manual Model DRX-4C
Indicates the scale is in the counting mode.
Indicates NDC verification is disabled. **
Indicates NDC verification is enabled. **
Indicates to place a container on the pan and tare it by
pressing the T key. **
Indicates to begin filling the prescription in order for the
count to begin. **
Indicates the counting operation is finished; to start a new
count, press the C key. **
CHAPTER 4
Indicates SUM is not available. There are no ingredients
entered into the scale's memory.

Getting Started
5
1. Carefully remove the scale, pan,
scanner, and all of its components out
of the packaging and place them on a
stable base where the scale will not be
affected by any mechanical vibrations
or air movements.
2. After removing the pan base and the pan from their packaging, carefully
install the pan base onto the scale by placing it on the pan support located
in the middle of the scale. Once the pan base has been installed, carefully
place the pan on the base as shown below.
Instruction Manual Model DRX-4C
3. Connect the scanner to the scale by plugging in the RJ connector to the
scanner and the RS232 connector to the scale. The RS232 port is
located in the rear of the scale. Using a small flat-head screwdriver,
tighten the connector screw to secure the cable and prevent it from
unintentional unplugging.
CHAPTER 5
Table des matières
Autres manuels Fulcrum Échelle