OPERATING TTHE FFIRE ((manual ccontrol mmodels)
The pilot is visible through the left hand side of the front ceramic strip. Push in and turn the control knob to the
SPARK position, and hold there for a few seconds.
Continue turning anti-clockwise through the spark click to the PILOT light position, ensuring the pilot has lit. If
not, return the knob clockwise, and repeat.
When the pilot lights after the spark, keep the knob depressed
for approximately ten seconds. Now release the knob and the
pilot should stay alight. If not, retry ignition. If the pilot is extin-
guished during use, wait three minutes before repeating the igni-
tion procedure.
To achieve the HIGH setting, push the control knob in slightly
and continue turning anti-clockwise to the high (large flame)
position. The main burner should light after a few seconds.
To decrease the setting to LOW, turn the control knob clockwise
to the low setting.
To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot
position and release.
To turn the fire OFF, keep the knob pressed in, return to the off position and release.
A safety interlock prevents re-ignition of the pilot flame until the thermocouple has cooled sufficiently to allow
the magnetic valve unit to reset itself.
OPERATING TTHE FFIRE ((remote ccontrol mmodels)
The gas valve has two control knobs ;
Turn the main burner control knob (shown on left
hand side of control valve) fully anti-clockwise.
Turn ignition knob (shown on right hand side of con-
trol valve) slightly left towards the ignition position
until reaching the stop, press down and hold for a
few seconds until pilot gas is flowing.
Continue pressing down the knob while turning fur-
ther to the left to activate the piezo spark, continue
to hold the knob down for a further 10 seconds after
the pilot has been lit. If the pilot does not light repeat
the previous steps.
Upon lighting the pilot and after the further 10 sec-
onds, release the knob and turn further to the left to the ON position. The main burner will light and be controlled
in accordance with the main burner control knob setting. Adjust the main burner control knob to the desired set-
ting.
If the pilot is extinguished during use of the fire, you must wait three minutes before repeating the ignition pro-
cedure.
To turn the main burner OFF whilst keeping the pilot flame lit, turn the ignition control knob to the pilot position
then only the pilot will remain lit.
To shut the fire off completely, press the ignition control knob down and continue turning to the right from the
pilot position to the OFF position.
A safety interlock prevents re-ignition of the pilot flame until the thermocouple has cooled sufficiently to allow
the magnetic valve unit to reset itself.
8
10.1
10.2