flamco MeiTronic W10B Manuel utilisateur

DEDE
W10B, W10, W20
Weather compensated heating controller
Witterungsgeführte Heizungsregler


3
EN
WEATHER COMPENSATED
HEATING CONTROLLER
W10B, W10 AND W20
INTRODUCTION
Weather compensated controllers W.. are intended for control of direct and/or mixing
heating circuit or two mixing heating circuits and d. h. w. warming with a boiler, solar
collectors and other energy sources.

4
EN CONTENTS
Introduction .....................................................................................................................................................3
USER MANUAL
Controller description..................................................................................................................................6
Initial controller setup..................................................................................................................................7
Graphic LCD display...................................................................................................................................10
Description of symbols presented on the display........................................................................... 11
Help, messages and warnings screen..................................................................................................16
Entering and navigating throug the menu ........................................................................................ 17
Menu structure and description............................................................................................................. 18
Temperature settings................................................................................................................................ 23
User functions ..............................................................................................................................................24
Operating mode selection....................................................................................................................... 27
Setting time programs.............................................................................................................................. 29
Basic settings ................................................................................................................................................ 31
Data overview .............................................................................................................................................. 33
SERVICE SETTING MANUAL
Controller parameters...............................................................................................................................34
User parameters.......................................................................................................................................... 35
Service parameters ....................................................................................................................................42
Parameters for floor screed drying .....................................................................................................65
Factory settings ..........................................................................................................................................66
Basic descriptions of controller operation .......................................................................................67
Mixing heating circuit.....................................................................................................................67
Direct heating circuit......................................................................................................................69
Heating curve....................................................................................................................................70
Liquid fuel boiler .............................................................................................................................. 72
Heat pump.......................................................................................................................................... 73
Pump for additional mixing in the boiler (Bypass pump) ............................................... 73
Domestic hot water ........................................................................................................................74
Domestic hot water circulation..................................................................................................76
Remote heating activation...........................................................................................................76
Operation of heating systems with two heat sources...................................................... 77
Divert valve operation by systems with two heat sources............................................. 78
Dierential controller.....................................................................................................................80
Minimum R6 pump speed level setup .....................................................................................80
Solar collector pump - impulsive mode................................................................................... 81
Source control with the Y2 analogue output ....................................................................... 82
Operation modes by sensors malfunction............................................................................. 83
Marking and description of temperature sensors...............................................................84
Sensor simulation ............................................................................................................................84

5
ENCONTENTS
INSTALLATION MANUAL
Controller installation................................................................................................................................ 85
Electrical connection of the controller...............................................................................................86
Connection of cables and sensors....................................................................................................... 87
Connection of temperature sensors ..................................................................................................88
Domestic hot water tank .........................................................................................................................89
RCD room units ...........................................................................................................................................90
Expanding the system on multiple heating circuits.......................................................................91
Connction of controller with internet cloud service HeatNext ................................................ 93
Installation and connection of VT safety limiter ............................................................................94
Controller malfunction and servicing ................................................................................................. 95
Technical data..............................................................................................................................................96
Disposal of old electrical & electronic equipment.........................................................................97
Hydraulic schemes .................................................................................................................................. 203

6 User Manual
EN
7
9
10
8
4
5
3
6
2
1Graphic display. button (one step back,
decrease).
Y2 output for energy source control. button (enters a menu,
confirms selection).
Y1 output for solar circulation
pump control.
button (Help).
button (one step forward,
increase).
Cover of the connection area.
button (Esc - return to previous). Screw for fastening the cover.
CONTROLLER DESCRIPTION
8
10
96
5
7
2
1
3
4

7User Manual
EN
INITIAL CONTROLLER SETUP
W.. heating controllers are equipped with an innovative solution which enables the
setup of controller in just three or four easy steps.
When the controller is connected to the network for the first time, the display first
shows the program version and company logo and then the first step of the procedure
for controller settings is presented.
STEP 1 - SET LANGUAGE
The controller requires a confirmation of language
selection with the button. In case you chose the
wrong language, return to the language selection
with the button.
Use buttons and to select the desired language.
Confirm the selected language by pressing .
If you do not find the desired language in the first screen, move to the next
screen with .
All schemes with mixing heating circuit are
available for radiators and floor/wall heating.
STEP 2 - SET HYDRAULIC SHEME
Select a hydraulic scheme for controller operation.
Move between schemes with buttons and
.
Confirm the selected scheme by pressing .

8 User Manual
EN INITIAL CONTROLLER SETUP
Later you can change the selected hydraulic scheme with service
parameter S1.1.
Later you can change the heating curve steepness with parameter P2.1.
The meaning of heating curve slope is described in chapter “heating curve”.
3. STEP - SET THE HEATING CURVE STEEPNESS FOR THE
FIRST CIRCUIT
The controller requires a confirmation of hydraulic
scheme with the button.
In case you choose the wrong scheme, return to
scheme selection with the button.
Set the heating curve steepness for room heating for
the first heating circuit.
Change the value with buttons and .
Confirm the selected value by pressing .
The controller requires a confirmation of the set
heating curve steepness with the button.
In case you choose the wrong heating curve
steepness, return to heating curve steepness
selection with the button.

9User Manual
ENINITIAL CONTROLLER SETUP
Later you can alter the set heating curve steepness with parameter P3.1.
The first and the second heating circuits are marked with their according
numbers on hydraulic schemes.
4. STEP - SET THE HEATING CURVE STEEPNESS FOR THE
SECOND CIRCUIT1
Set the heating curve steepness for room heating for
the second heating circuit.
Change the value with buttons and .
Confirm the selected value by pressing .
The controller requires a confirmation of the
heating curve steepness setting with the
button. In case you choose the wrong curve
steepness, return to heating curve steepness
selection with the button.
RESET
Disconnect the controller from power supply.
Press and hold the button and connect power supply.
Attention! The controller will be reset and requires additional setting. When
the controller is reset, all of its previous settings are deleted.
1This setting is not available in schemes with only one heating circuit.

10 User Manual
EN GRAPHIC LCD DISPLAY
On the LCD display we can look up all the important data for the controller operation.
DESCRIPTION AND PRESENTATION OF THE BASIC SCREEN
Review of temperatures, protection
functions and other data.
Heating circuit
Operation
mode
User functions
Room unit
Review of measured temperatures
Status of the controller’s control
outputs
Time and
date
Messages and
warnings
REVIEW OF DATA ON THE SCREEN:
Operation mode and user functions appear separately for each circuit on the upper
third of the screen. To switch between heating circuits and the screen with the
hydraulic scheme review use the button.
Temperatures, active outputs, protection functions and other data appear in the
middle section of the screen. To review temperatures and other data, use buttons
and . The number of sensors and other data displayed on the screen
depends on the selected hydraulic scheme and controller settings.
If you wish to retrieve the desired data after using the keyboard, look for the
data with buttons and , then confirm it by pressing the
button for 2 seconds.
If you press the button for 2 seconds, the temperature review will change
from a single line review into a double line review or vice versa. In the two-line
temperature review, the measured temperature appears in the first line, and
the desired or the calculated temperature appears in the second line.
Ce manuel convient aux modèles suivants
2
Table des matières
Langues :
Autres manuels flamco Contrôleurs