FLAJZAR EMA2 Manuel utilisateur

EN 1
Dear Customer,
thank you for purchasing the EMA2 alarm system – a car
alarm developed by FLAJZAR s.r.o.
The EMA2 is a miniature GSM car alarm designed to secure
almost any type of car without the need for installation and
it’s also easily transported from a car to a car.
Car security has never been easier to install and more en-
joyable to use! Installation of the EMA2 car alarm is based
simply on inserting the alarm into the cigarette lighter
socket. With automatic activation and deactivation of the
protection with authorisation pendants, you don’t have
to worry whether or not you have forgotten to turn the
protection on or o. The protection activates itself when
you leave the car and it deactivates itself when you arrive
to your car.
EMA2 – an innovated successor
to the popular car alarm

EN 2
Main advantages of the EMA2:
No installation
Automatic activation and deactivation of the protection
Very easy to set up
Backup battery life up to 7 days
Minimal operating costs
Possibility of upgrading the alarm with a GPS receiver
and wireless detectors
Optional accessories for the EMA2:
Authorisation pendants
GPS receiver
Wireless PIR motion detector
Wireless shock detector
Combined wireless detector
Power cord extension
The EMA2 doesn’t aim to replace expensive built-in
alarms and satellite systems, but it is a very welcome op-
tion that enhances the security of your vehicle – whether
you are parking at a shopping centre, on city streets, you
are possibly shing or at weekend cottage.
Summary of the main features and functions
A unique security device that requires no installation
Automatic activation and deactivation of the protection
Designed for any type of car*
An integrated shock sensor directly in the alarm
It can be upgraded with additional sensors
It allows you to connect a GPS receiver for accurate
positioning
In the case of a space violation, it calls and sends an
SMS to up to 3 phone numbers
It has a built-in backup battery
It can be congured easily with a PC, SMS or multi-
function button

EN 3
* A standard 12V on-board socket for a cigarette lighter with
an internal diameter of 20.5mm to 21.5mm is a prerequisite
for the device
Commissioning
Insert an activated micro SIM card from your mobile
operator with the PIN code o.
Insert the micro SIM card and briey press the multi-
function button at the top of the alarm. The green light
in the button lights up and after a while, the blue light
starts to ash.
This means that the EMA2 is logged on to the mobile
operator’s network and is ready for use.
Teach the EMA2 your phone number:
Briey press the button again, the green and blue lights
should ash alternately - EMA2 is in learning mode.
Send a text message to the EMA2 (SIM card telephone
number in EMA2) from your mobile phone with the fol-
lowing text: “LET’S GET STARTED”, after a while you will

EN 4
receive a welcome SMS, your phone number has been
stored in the EMA2.
Teach the EMA2 your authorisation pendant, or other
accessories:
Briey press the button, the green light alternates with
the blue – the EMA2 is in learning mode. Using a paper
clip, briey press the authorisation pendant’s learning
button, both LEDs will ash after learning is successful.
From now on, the EMA2 is set to factory default. Other
settings can be made at any time by connecting to a PC
and the EMA2Cong conguration programme.
Note: Insert the newly purchased SIM card into your mobile
phone and disable the PIN code. To activate and validate a
new card, we recommend that you to make the rst outgoing
call and send an SMS – therefore, the SIM card will be activat-
ed in the operator’s network.
Note: We recommend that you to turn o the voice mailbox
on the SIM card of the EMA2 alarm as well as the welcome
melody or other operator messages. This setting needs to be
carried out on the mobile phone with the SIM card inserted
from the EMA2 alarm.
Note: The EMA2 contains an integrated Li-Ion battery that
can discharge when it hasn’t been used for a long time.
Therefore, we recommend charging the EMA2 alarm prior to
its rst use. Full charge takes approximately 3 hours. Insert
the EMA2 into the 12V board connector or connect to a PC
with a USB cable.

EN 5
EMA2 default setting
Default conguration program and SMS password: 1234
Alarm call is turned on
Sending SMS when alarm is on
Service SMS is turned on
Controlling the monitoring state by calling is on
Daily SMS limit is enabled with a limit of 50 outgoing SMS
Intercept is switched on
Integrated shock detector is on, medium sensitivity
Activation and deactivation of the protection mode
The EMA2 allows two ways of activating and deactivat-
ing the protection:
Automatic activation and deactivation with an au-
thorisation pendant
When you leave the car with the authorisation pen-
dant, the EMA2 starts counting 60 seconds. If during
this time it doesn’t detect the presence of the authori-
sation pendant, it activates the protection.
When you are approaching the car with an authorisa-
tion pendant, the EMA2 detects the presence of the
pendant and automatically switches the protection o.

EN 6
Manual activation and deactivation using a mobile
phone
In this mode, the protection status is controlled by the
user – with a free ringtone or SMS. When leaving the
car, call the EMA2 or send an SMS with a command to
activate protection.
Before approaching the car, call the EMA2 or send an
SMS with a command to deactivate the protection.
Description of the signalling indicators
Both indicator lights are o – switched o
Green is on continuously – switched on, not protecting
Green ashes briey once every 2 seconds – switched
on, protecting
Green ashes briey once every second, blue is o –
sleep, protecting
Blue ashes – GSM signal strength is OK
Blue doesn’t ash – weak or no GSM signal
Green and Blue ashing alternately – learning mode
is on

EN 7
Operating conditions
O:
GSM o
Integrated sensor and wireless sensors are switched o
The EMA2 switches to this mode by pressing the button for a
long time or by discharging the backup battery. Button deac-
tivation is enabled only if the EMA2 is not in protection mode
(the authorisation pendant is within range or the protection is
turned o via an SMS command).
Switched on:
GSM turned on
Integrated sensor and wireless sensors are turned on
The EMA2 switches to this mode in the following cases:
Connection of 12V power or USB
Alarm activation with an integrated or wireless sensor
By pressing the button (if the EMA2 has been in Sleep or O
mode)
Sleep:
GSM turned o
The integrated sensor and wireless sensors are
turned on
The EMA2 switches to this mode in the following cases:
12V power or USB is disconnected and the protection is on
2 hours after the alarm was triggered
The EMA2 in a permanent power plug
The EMA2 is permanently on, it can receive SMS and calls.
The EMA2 in a plug with power o/on
As soon as the power is switched o and the protection
is activated (pendant out of reach, or SMS/call activa-

EN 8
tion), the EMA2 switches to Sleep mode after ve min-
utes to save the backup battery’s power.
Upon entering the car, an integrated or wireless sen-
sor is triggered, the EMA2 switches from Sleep mode
to ON mode and counts 20 seconds to catch the signal
from the pendant and as soon as it receives the signal,
it turns the protection o, otherwise it will trigger the
alarm.
After an alarm, the EMA2 remains in ON mode for two
hours, the two-hour interval begins to count down
from the moment the user sends an SMS.
Conguration using a computer
The EMA2 alarm can be congured easily using a com-
puter with OS Windows.
Download the EMA2Cong conguration program
from www.ajzar.cz, run the installation and follow the
installation program’s instructions.
After successful installation, an EMA2Cong icon is cre-
ated on the desktop, which can be used to start the
program.
Note: The installation and operation of the programme must
be carried out with PC Administrator rights. If during the in-
stallation, Windows alerts you to run and install an unknown
software, proceed with the installation.
Note: We recommend that you install Microsoft Net Frame-
work 3.5 from Microsoft’s Website for the application to run
properly.
Note: A password is required when running the program with
the connected EMA2 alarm (it is common for both SMS com-
mands as well as software conguration). The default pass-
word is 1234 and can be changed (recommended).

EN 9
Page 1 of the program – Settings
1. File – allows you to load and save the EMA2 settings
from a le and update the rmware from the le.
2. Settings – switches to the rst page of the congu-
ration program with the EMA2 settings
3. Wireless accessories – switches to the second page
of the conguration program with a wireless accessory
setting
4. Maintenance – allows to turn on/o the new rm-
ware automatic check and conguration program and
perform manual update checks
5. Languages – allows you to change the congura-
tion program language
6. About the application – opens the EMA2 instruc-
tion manual
7. Setting up phone numbers – the EMA2 allows
23231818 19 2020 2121 2222
17
1616
1515 14
1313
11109988
1212
77
112233445566

EN 10
communication with up to three phone numbers.
Telephone numbers have to be entered in an interna-
tional format with the dialling code: +420123456789
8.) Control – allows this phone number to control the
state of protection by calling
9. Call – in the case of an alarm, this number will be
dialled
10. SMS – in the case of an alarm, an SMS will be sent
to this phone number
11. Service – a service SMS will be sent to this phone
number
12. Password – change the password to access the
conguration program and SMS. Enter the new pass-
word in the “New” eld and “Check” eld and save the
settings with the“Save”button
13. Device name – this text will be at the beginning of
each outgoing SMS sent by the EMA2
14. Credit number –is a number to call to nd out
the amount of credit on pre-paid SIM cards. Enter the
number according to the SIM card phone provider in
the EMA2
15. Daily SMS limit – maximum number of outgoing
SMS in 24 hours. Enables/disables daytime SMS limit
feature (max. 50 SMS). Maximum: maximum amount of
outgoing SMS in 24 hours. Today sent: current amount
of outgoing SMS in 24 hours
16. Microphone – enables/disables listening function
17. Integrated motion detector – setting the vibra-
tion sensor inside the EMA2 On/O - Enables/disables
the integrated sensor. Sensitivity – setting the sensitiv-
ity of the integrated sensor
Table des matières
Autres manuels FLAJZAR Système de sécurité
Manuels Système de sécurité populaires d'autres marques

EDM
EDM Solution 6+6 Wireless-AE Manuel utilisateur

Highway Safety Group
Highway Safety Group EA401 Manuel utilisateur

Siren
Siren LED GSM Manuel utilisateur

Detection Systems
Detection Systems 7090i Instructions de montage

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuel utilisateur

Siemens
Siemens FDM273 Manuel utilisateur













