FISNAR VPP50 Manuel utilisateur

VPP50 Vacuum Pickup System Operating Manual
© 2020 Fisnar - 2 - VPP50 Rev 01
Table of Contents
Machine Overview 3
Product Safety Statements 4
Specifications 6
Accessories 6
External Controls 7
Machine Setup 10
Vacuum Pickup Pen Setup 11
Operation Mode 12
External Machine Actuation 13
Spare Parts List 14

VPP50 Vacuum Pickup System Operating Manual
© 2020 Fisnar - 3 - VPP50 Rev 01
OVERVIEW
Model VPP50 Vacuum Pick System
The VPP50 Vacuum Pickup System is designed for safely and efficiently picking up and
placing delicate lightweight components with ease. Unlike conventional tweezers, the use of
a rubber suction cup prevents possible accidental damage or contamination to the
component during the lifting and positioning process.
Its simple pneumatic only control and easy to use finger actuated design; allows the system
to be used in workspace environments, where electrical supply is not available or not
permitted.
Operation Mode
1.) The component is lifted by lightly placing the suction cup on the component.
2.) The operator’s finger is then positioned over the hole on the finger grip of the vacuum pickup
pen and kept held down to apply the vacuum through the suction cup.
3.) This then allows the component to be picked up and safely positioned.
4.) The operator’s finger can then be removed from the hole on the finger grip, which stops the
vacuum, allowing safe release of the component.
Compliant for use in ESD safe environments
Simple set-up and operation
Manually finger actuated design
Adjustable vacuum control
Pneumatic only system, allows it to be used in workspace environments where electrical supply is
not available or not permitted
Lightweight ergonomic pickup pen included
Compact & durable aluminum housing designed for industrial work environments.
Stand included for safe storage of vacuum pick-up pen when not in use.
A selection of ESD safe tips and vacuum cups included to ensure compatibility with differing
applications

VPP50 Vacuum Pickup System Operating Manual
© 2020 Fisnar - 4 - VPP50 Rev 01
General Precautions
Do not operate the machine in excess of its maximum ratings / settings.
Make sure that the input air supply is clean and dry. A 5 micron air filter/regulator
(item number 560567) is recommended to ensure the input air supply is clean
and dry.
Do not smoke or use near an open flame.
Do not expose the machine directly to sunlight.
Avoid cleaning the machine with aggressive solvents – neutral detergents are
preferred.
Place the vacuum pickup pen in the supplied holder when not using the machine.
This will prevent the suction cup from being damaged – refer to figure A below.
Fig. A
VPP50 Malfunction
If the machine malfunctions, shut down the machine immediately. This can be
done by shutting off the compressed air supply connected to the air input
connector on the back of the machine.
SAFETY

VPP50 Vacuum Pickup System Operating Manual
© 2020 Fisnar - 5 - VPP50 Rev 01
Inappropriate Use
If the machine is used in a way other than described in this manual, it may cause damage
to self or property.
Do not use any components with the machine other than Fisnar authorized
components.
Do not use incompatible materials.
Do not make any modifications to the machine.
All repairs are to be done using Fisnar specified spare parts.
Do not operate the machine in excess of its maximum ratings / settings.
Fire Prevention
Refer to the following instructions to avoid any fire or explosion.
Assess your surroundings and the location of the nearest fire extinguisher and
Emergency Exit.
Do not smoke or use near an open flame.
Do not expose the machine directly to sunlight.
Maintenance
The VPP50 is generally a maintenance free machine. However, to ensure smooth
operation please follow the below instructions.
Only use non-woven cleaners on the machine.
Avoid cleaning the machine with aggressive solvents – neutral detergents are
preferred.
Ensure that compressed air supply to the machine is clean and moisture free.
Place the vacuum pickup pen in the supplied holder when not using the
machine. This will prevent the suction cup from being damaged.
SAFETY

VPP50 Vacuum Pickup System Operating Manual
© 2020 Fisnar - 6 - VPP50 Rev 01
ACCESSORIES
Item Description Quantity
561851 Air Inlet Hose Assembly 1
5601947 ESD Grounding Cable Assembly 1
5601948 Vacuum Pickup Pen Holder 1
580046-ESD Vacuum Pickup Pen – ESD Safe 1
QK-VTK Vacuum Tip Kit 1
Note: Standard Vacuum Pickup Pen (part # 580046) & ESD Workstation kit (part # ESD-WSK-US / ESD-WSK-
EU / ESD-WSK-UK) available to purchase separately.
Part # 580046
SPECIFICATIONS
Dimensions (W x D x H): 3.78” x 5.04” x 3.00” (96 x 128 x 76 mm)
Weight: 0.84 lbs (0.38 kg)
Relative Humidity: 20 – 90% (No Condensation)
Operating Temperature: 50 – 104
℉
(10 – 40
℃
)
Air Input: 100 psi (7 bar) max
Vacuum: Up to 400 mm-Hg (15.75in.-Hg)
Maximum Pickup Weight Up to 4.4oz (125g)
Standards: RoHS Compliant, ESD Safe
Part # ESD-WSK-US
Part # ESD-WSK-EU
Part # ESD-WSK-UK

VPP50 Vacuum Pickup System Operating Manual
© 2020 Fisnar - 7 - VPP50 Rev 01
EXTERNAL CONTROLS
FIG. 1: External Controls – Overview
Item
Illustration Item
Illustration
1 Vacuum Inlet Port 5 ESD Grounding Point
2 ESD Input Connector 6 Air Inlet Port
3 Vacuum Control
4 Exhaust Port
REAR
FRONT
2
3
1
6
4
5

VPP50 Vacuum Pickup System Operating Manual
© 2020 Fisnar - 8 - VPP50 Rev 01
EXTERNAL CONTROLS
FIG. 2: External Controls – Front
1. Vacuum Inlet Port The air connector on the vacuum pickup pen is connected here.
2. ESD Input
Connector
The electrical plug on the vacuum pickup pen is connected here.
This does not apply if using optional vacuum pickup pen (#580046).
3. Vacuum Control
Adjusts the amount of vacuum pressure being used, for the suction cup
to safely and securely pick up the component.
Turn the knob counterclockwise to increase the vacuum pressure to
the desired level.
Vacuum pressure will not be generated until the foot pedal has been
pressed.
3
1
2

VPP50 Vacuum Pickup System Operating Manual
© 2020 Fisnar - 9 - VPP50 Rev 01
EXTERNAL CONTROLS
FIG. 3: External Controls - Back
1. Exhaust
When the machine is in use, air will be exhausted from this connector.
A muffler (#560024) can be fitted into the exhaust outlet port to reduce
the emitted noise of the exhausted air.
2. ESD Grounding
Point
ESD grounding cable (#5601947) is connected here. The other end of
the cable is to be connected to a suitable common ESD Safe grounding
point within the workplace environment.
3. Air In Push
Connector
External Compressed air 70-100 psi (5-7 bar) is to be connected here,
using the supplied ¼” OD air inlet hose.
3
1
2

VPP50 Vacuum Pickup System Operating Manual
© 2020 Fisnar - 10 - VPP50 Rev 01
MACHINE SET UP
FIG. 4: Machine Setup
1. Connect air hose (1) from compressed air 70-100 psi (5-7 bar) to the air inlet port on the
back of the machine. See FIG. 4.
2.
Insert the air connector and ESD grounding plug (2) from the vacuum pickup pen to the
ports on the front of the machine. See FIG. 4.
If using optional vacuum pickup pen (#580046) only the air connector will need to be
attached to the port on the front of the machine.
3.
Insert the ESD grounding cable (3) into the port on the back of the machine. The other
end of the cable is to be connected to a suitable common ESD Safe grounding point
within the workplace environment. See FIG. 4.
If there is no requirement for the machine to be used in an ESD Safe work environment,
this step can be ignored.
1
2
3
Table des matières