Firefly cygnus hpg Manuel utilisateur

CYGNUS HPG 12-24 KVA
User manual v1.6
For use with the following models:
CYG3/12/37/AGM CYG3/12/50/AGM
CYG3/18/37/AGM CYG3/18/50/AGM
CYG3/24/37/AGM CYG3/24/50/AGM
www.reycleanenergy.co.uk

Page 2 CYGHPG12-24-User-Manual-v1.6.indd
1 Introducon 4
1.1 Foreword 4
1.2 Convenons 4
1.3 Warnings 5
1.4 Standards & Regulaons 6
1.5 Disposal & Recycling 6
1.6 Firey Contact Details 6
1.7 About Firey 7
2 Geng Started 8
2.1 Storage 8
2.2 Transporng, Liing & Posioning 8
2.2.1 Transportaon 8
2.2.2 Liing (Loading/Unloading) 8
2.2.3 Posioning 9
2.3 The Cygnus HPG Control Panel 10
2.4 Connecng Cygnus HPG 12
2.4.1 Earth aachment: Installing an Earth Rod 12
2.4.2 Input Opons 13
2.4.3 Connect The AC Input 15
2.4.4 Connect The AC Output 17
3 General Operaon 18
3.1 Turning The Power On 18
3.1.1 Descripon Of The Power Modes 18
3.1.2 Switching On The Cygnus HPG 19
3.1.3 Monitoring Baery Bank State of Charge 20
3.1.4 Emergency Stop Buon 21
3.1.5 Turning O The Cygnus HPG 21
3.1.6 Disconnecng Cygnus HPG 22
3.2 Charging From An AC Supply 22
3.3 System Sengs 23
TABLE OF CONTENTS

Page 3CYGHPG12-24-User-Manual-v1.6.indd
FIGURES
TABLE OF CONTENTS
Fig. 1 - Control Panel 10
Fig. 2 - Earth Point 12
Fig. 3 - Earth Rod 12
Fig. 4 - Input Current Sengs for use with 63 A Input 14
Fig. 5 - Inputs, Outputs and Circuit Breakers 16
Fig. 6 - 5 mm Double Barb Key 17
Fig. 7 - AC Output Bus Bar Connecons 17
Fig. 8 - The RCC 03 Baery Monitor Screen 20
Fig. 9 - Auxiliary Bus Bar 28
3.4 Care And Maintenance 26
3.4.1 General Cleaning 26
3.4.2 Caring For The Baery Bank 26
3.4.3 Tesng Cygnus HPG 26
3.5 Troubleshoong 27
4 Appendices 28
4.1 Connecng To A Fuel Generator For Automac Stop/Start 28
4.1.1 Control Panel Auxiliary Connecons 28
4.1.2 Bus Bar Auxiliary Connecon 28
4.2 Earthing Cygnus HPG 29
4.2.1 When Used Inline With A Fuel Powered Generator 29
4.2.2 When Used As A Standalone Power Source 29
4.2.3 When Charging A Standalone Generator from An AC Source 29
4.3 Warnings 29
4.3.1 Safety Noce Regarding The Units’ Baeries 29
4.4 Technical Data 30
4.5 Warnings
4.5.1 Safety Noce Regarding The Units’ Baeries

Page 4 CYGHPG12-24-User-Manual-v1.6.indd
1 INTRODUCTION
1.1 Foreword
Firey takes this opportunity to congratulate you on receiving your new Cygnus
HPG.
Designed and manufactured within the United Kingdom using only the nest
European sourced electrical components, your new Cygnus HPG oers
sustainable power generaon with the reliability that you demand.
The purpose of this manual is to introduce you to Cygnus HPG and provide you
with a guide to its safe installaon and operaon. This manual describes how
your Cygnus HPG works, will help you with fault nding and examines what key
components are doing and why.
1.2 Convenons
Throughout this user manual the following symbols are used:
W A R N I N G
This symbol warns of the presence of a dangerous voltage
which could cause harm to the operator or others.
This symbol indicates the potenal of damage to the unit or
connected devices.
This symbol indicates important or useful informaon.

Page 5CYGHPG12-24-User-Manual-v1.6.indd
The following terms are used in this manual to provide greater clarity:
• Firey will be referred to as “The manufacturer”.
• The Cygnus HPG Hybrid Power Generator will be referred to as “Cygnus
HPG” or “Unit”.
• Any items that consume power will be referred to as “Consumers”.
1.3 Warnings
This user manual is an important part of Cygnus HPG. It
must be kept available to all operators and kept close to the
unit so that it can be referred to at any me.
W A R N I N G
When the unit is operang it generates potenally lethal
voltages. Work must only be performed on the unit by the
manufacturer or a qualied service engineer approved by
the manufacturer.
All items connected to the unit including distribuon cables
and boxes should be regularly checked and adhere to the
same local regulaons and standards as a regular grid-ed
mains installaon.

Page 6 CYGHPG12-24-User-Manual-v1.6.indd
1.4 Standards & Regulaons
Cygnus HPG conforms to the following standards and regulaons:
• Manufactured in compliance with ISO 9001:2008
• LVD 2006/95/EEC: EN 50178:1197, EN 62040-1:2008
• EMC Direcve 2004/108/EC: EN 61000-6-2:2005, EN 61000-6-3:2007,
EN 61000-3-2:2006, EN 61000-3-12:2005, EN 62040-2:2006
• IP44
• WEEE Direcve
1.5 Disposal & Recycling
Cygnus HPG comprises of components that must be disposed of responsibly.
For the sake of the environment many of the components within the unit can be
recycled or reused. Firey will ensure the safe decommissioning and recycling
of the unit at no charge if the unit is returned to the manufacturer. Otherwise,
please contact the manufacturer for more informaon on safe and proper
decommissioning of your Cygnus HPG.
1.6 Firey Contact Details
Firey Solar Generators Limited
Unit 20 Clie Industrial Estate
South Street
Lewes
East Sussex
BN8 6JL
United Kingdom
Tel: +44 (0) 1273 40 95 95
Fax: +44 (0) 1273 40 95 96
E-mail: info@reycleanenergy.co.uk
Web: www.reycleanenergy.co.uk
IP56

Page 7CYGHPG12-24-User-Manual-v1.6.indd
1.7 About Firey
Firey is the market leading expert in the design and manufacture of o-grid,
portable Hybrid Power Soluons for temporary and permanent power
applicaons. Firey has built its highly regarded reputaon within the industry,
based on excellent customer service and product reliability. Founded in 2007 the
Company connues to develop innovave soluons to cater to the needs of its
ever growing customer sectors.
The Company oers green energy products and services that meet the needs of
environmentally concerned individuals and organisaons internaonally, that
are looking to reduce their carbon emissions caused by the use of fossil fuels
and diesel powered equipment. The unique range of renewable technology
soluons produce zero emissions, are truly silent running and eliminate the need
for fuel.
The systems are manufactured in the UK, under an ISO 9001:2008 approved
quality control system. Component suppliers are carefully selected to ensure
high levels of reliability and performance of the nal product. Installaon and
stringent tesng is carried out to ensure compliance with EU and local legislaon
where applicable.

Page 8 CYGHPG12-24-User-Manual-v1.6.indd
2 GETTING STARTED
2.1 Storage
1. Cygnus HPG is designed to be used and stored outside. However, to
prevent unnecessary weathering it is recommended that the unit is
stored inside when possible.
2. It is recommended that the baery bank is charged regularly while in
storage. Refer to "3.2 Charging From An AC Supply" on page 21 for
further informaon.
3. The emergency stop should be engaged (pushed in) and output
protecon switches should be switched o when in storage and not
being charged to prevent unnecessary discharge of the baery bank.
2.2 Transporng, Liing & Posioning
This unit is considerably heavier than regular fuel powered
generators of similar physical dimensions. Be sure to double
check the capacity of liing equipment.
2.2.1 Transportaon
1. Cygnus HPG can be transported using its oponal trailer, light or heavy
goods vehicle with adequate available payload. Check the relevant
transportaon documentaon for suitability.
2. The gross weight of the unit can be found on the rang plate posioned
on the le hand side of the unit.
3. It is recommended that the unit is secured using suitable straps when
in transit to prevent it from moving.
2.2.2 Liing (Loading/Unloading)
1. Cygnus HPG must be loaded or unloaded using the correct equipment
operated by suitably trained personnel.
2. Using the fork pockets, Cygnus HPG can be loaded or unloaded with a
suitable fork-li truck or telehandler.
3. Cygnus HPG can be safely lied using its integral liing ring.

Page 9CYGHPG12-24-User-Manual-v1.6.indd
Always check the rang plate to ascertain the gross weight
of the unit.
The unit must remain upright at all mes.
2.2.3 Posioning
1. The unit must be posioned upright on a at, solid surface. Ensure that
the unit is not at risk from being submersed in water above the fork
pockets.
2. The unit should be posioned as close as possible to the chosen input
source (e.g. Gen. Set, solar array) and where necessary, close to its
earth point.
3. Ensure adequate space is allowed for venlaon on all sides and that
vents are not obstructed.
Refer to liing equipment’s operaon manual for liing
capacity and manufacturer’s operang instrucons.

Page 10 CYGHPG12-24-User-Manual-v1.6.indd
2.3 The Cygnus HPG Control Panel
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Fig. 1 - Control Panel
Table des matières