FireAngel WFS-627 Manuel utilisateur

WFS-627 User Manual
Wi-Safe Strobe
Alert System
Part of the Wi-Safe Home Safety
System
N`$JX]\


1
INTRODUCTION 2
OVERVIEW 3
DEFINITIONS 4
APPLICATION 5
POSITIONING 5
LIMITATIONS 6
HOW TO INSTALL YOUR STROBE ALERT
SYSTEM 10
1 Preparation
2 Connect the Rechargeable Battery
3 Installation
4 Connecting to Wi-Safe Alarms
5 Testing
OPERATION 16
6 Basic Function
7 Removal of AC (Mains) Power
8 Battery Care
9 System Integrity Check
10 Visual Indicators
WHAT TO DO IF YOUR STROBE ALERT
SYSTEM TRIGGERS 21
REPAIR 25
TROUBLESHOOTING 26
DISPOSAL 28
WARRANTY 28
RETURNS 30
CONTENTS

2
INTRODUCTION
Congratulations! You’ve made a wise investment
in an innovative product and your personal safety.
The Wi-Safe WFS-627 Strobe Alert System is
one of a new generation of domestic life safety
products from FireAngel, which combines the
latest technology and innovative design to provide
an aesthetically pleasing and effective contribution
to your re and carbon monoxide (CO) safety.
The Wi-Safe Strobe Alert System can only be
used in conjunction with Wi-Safe smoke and
carbon monoxide alarms.
What is Wi-Safe?
Wi-Safe is a FireAngel term to describe the
wireless, radio frequency (RF) communication
signal from Wi-Safe smoke or CO alarms to the
Strobe Alert System (or other Wi-Safe receivers),
using the FireAngel unique encryption protocol.
Wi-Safe Product Range suitable for use with
WFS-627 Wi-Safe Strobe Alert System
•Wi-SafeOpticalSmokeAlarmWSO-601
•Wi-SafeIonisationSmokeAlarmWSI-601
•Wi-Safe10YearOpticalSmokeAlarm
WSO-610
•Wi-Safe10YearIonisationSmokeAlarm
WSI-610
•Wi-SafeCarbonMonoxide(CO)Alarm
WCO-628
The WFS-627 Wi-Safe Strobe Alert System can
be used alongside the WBS-616 Remote Warning
Handset and any other FireAngel product containing
a Wi-Safe receiver.
The FireAngel range of products is constantly
being expanded. Please visit www.reangel.co.uk
to nd out about the latest additions to our
product range.

3
OVERVIEW OF THE
FIREANGEL WI-SAFE
HOME SAFETY SYSTEM
COMPONENTS
•StrobeAlertSystemWFS-627
•StrobeandVibratingAlertSystemWFSVP-629
•RemoteWarningHandsetWBS-616
•VibratingAlertSystemWVP-626
•SmokeAlarms,WSI-601,WSO-601,WSI-610,
WSO-610
•CarbonMonoxideAlarm,WCO-628
•OtherfutureWi-Safeproducts
All Wi-Safe products bear the
Wi-Safe logo
N`$JX]\
IMPORTANT: This user manual
contains important information
regarding the operation of your Strobe Alert
System. If you are installing this product for use
by others, you must leave this manual (or a
copy of it) with the end user.

4
DEFINITIONS
Strobe
High intensity ashing light
RF
Radio frequency, method of communication
LED
Light emitting diode (The 3 status indicators on
the front of the receiver box are LEDs)
AC Adaptor
Alternating current adaptor, plugs into mains
supply. The AC mains adaptor is rated at 230V
50Hz 0.075A input.
Encryption Protocol
A secure method of communication, identifying
alarms within an individual system.
This FireAngel Wi-Safe Home Safety System
consists of a Receiver Box with integrated
Strobe Light, with AC mains adaptor to be used
in conjunction with FireAngel Wi-Safe smoke or
carbon monoxide (CO) alarms.
The smoke and/or CO alarms should be
positioned in recommended locations specied in
the user manuals accompanying those products.
When your smoke or CO alarm triggers, it will
go into alarm and send a radio frequency signal
to the Wi-Safe Receiver Box. When the Wi-Safe
Receiver Box receives the signal, it will activate the
Strobe and the red LED visual indicator on the
Receiver Box will illuminate to indicate what type
of signal is being received.

5
APPLICATION
WARNING: The Strobe Alert
System is only designed to receive
signals from FireAngel Wi-Safe smoke or CO
alarms. It will not respond to other models
or brands of smoke or re alarm systems or
other FireAngel non Wi-Safe smoke or CO
alarms. The FireAngel Wi-Safe Home Safety
System is not intended as a substitute for a
complete re alarm system, as specied in BS
5839-6: 2004.
Your Wi-Safe smoke or CO alarms contain
transmitters only and will communicate with the
Wi-Safe Strobe Alert System (and other Wi-Safe
receiving products) only and will not communicate
with each other.
POSITIONING
WARNING: The Strobe Alert
System will only warn of smoke or
carbon monoxide if it receives a signal from a
recognised active alarm.
In which room should the Strobe Alert System be
installed?
It should be installed in the primary room
where you spend most of the time during
the day e.g. living room, kitchen, dining room.
Additional systems should be installed in any
room where you may need to be alerted in
the event of an alarm.
Where should the Receiver Box with Strobe be
positioned?
•Closetoapowersocketwhereitcanbeeasily
plugged in and does not create a tripping
hazard
•InapositionwhereyoucanseetheStrobe
light from anywhere in the room

6
•WhereitcanbesecuredtoawallOR where
it can be placed on a table (take care not to
knock the Receiver Box off the table)
•WhereyoucanseetheLEDindicatorsonthe
front of the receiver box
CAUTION: Do not put the Strobe Alert
System
•Outsidethebuilding
•Inacupboard
•Inadamporhumidarea
•Inanareawherethetemperaturecould
regularly drop below –5°C or rise above 40°C
•Whereitcaneasilybeknockedordamaged
WHAT ARE THE
LIMITATIONS?
Your Strobe Alert System requires a FireAngel
Wi-Safe smoke or carbon monoxide (CO) alarm
to trigger it by radio signal. The Strobe Alert
System will not operate in isolation (on its own),
with non Wi-Safe FireAngel smoke or CO alarms
or any alarms made by other manufacturers.Your
Strobe Alert System is designed to alert you by
ashing a high intensity light on the Receiver Box
when it receives a signal from an activated smoke
or CO alarm. Your Strobe Alert System may not
respond to a signal from a smoke or CO alarm if
the alarm and the Receiver Box are too far apart; if
there are obstructions that signicantly reduce the
signal (e.g. steel reinforcement in concrete); or if
there are other electrical or electronic equipment
that creates interference and obscures the signal.
Your Strobe Alert System will only alert you to
the triggering of a smoke or CO alarm if that
alarm has been recognised (see ‘Connecting to
Wi-Safe Alarms’ on page 12) by your Strobe Alert

7
System. After initial installation and testing, the
performance of the communication between the
smoke or CO alarm and your Strobe Alert System
may be compromised by changes in the building’s
structure or contents. Always test to ensure the
entire Wi-Safe Home Safety System (all alarms
and receivers) is still working after any changes to
your building’s structure, wiring, plumbing, heating
or changes in position of major items of furniture
(beds, sofas, shelving units, etc.)
We recommend that, as a minimum, you install a
strobe in a room where you are likely to spend
a lot of time during the day. To get you started
quickly your FireAngel WFS-627 has been
designed to detect a signal from any FireAngel
product with a Wi-Safe transmitter as soon as it
is activated. We highly recommend you uniquely
code your Wi-Safe system to your home, and
isolate your Wi-Safe system from other Wi-Safe
systems nearby. To do this go through the simple
section ‘Connecting to Wi-Safe alarms’ starting on
page 12 of your user manual.
The Strobe Alert System will not alert you to
a smoke or re situation unless it has been
triggered by a recognised and operational Wi-
Safe smoke alarm. Also it will not respond and
alert you that a high level of carbon monoxide
(CO) has been detected without the triggering
of a recognised and operational FireAngel Wi-
Safe CO alarm.
The FireAngel Wi-Safe Home Safety System may
not alarm before a re causes damage, injury or
death, as the smoke may not reach the smoke
alarm in time. Examples include smoking in bed
and violent gas explosions. The smoke alarm
may not respond in a reasonable time if it is not
installed in the best position or if obstacles, such as
furniture or closed doors, are located between the
smoke alarm and the re.
The Wi-Safe Home Safety System may not
alarm before a dangerous CO level causes illness,
poisoning or death, as the CO may not reach the
CO alarm in time.The CO alarm may not respond
in a reasonable time if it is not installed in the

8
best position or if obstacles, such as closed doors,
are located between the CO alarm and the source
of CO.
The Strobe Alert System requires both a
continuously powered AC electrical supply and
internal battery for its normal operation. The
battery accompanying this product is rechargeable
and charges when there is mains power to the
Receiver Box.
WARNING: Use only the battery
included in this pack as it has been
chosen specically for this application. Use of
other batteries may damage the product.
The battery provided is rechargeable and is
continuously charged when plugged into the
mains. Installation of the wrong type of battery
is dangerous and may cause harm or damage.
If the electrical supply fails or is removed, the unit
will continue to operate on its back-up battery for
up to 3 days.The yellow LED will ash twice every
5 seconds in the event of a low battery condition.
WHEN THIS OCCURS YOU MUST RESTORE
POWER WITHIN 3 DAYS TO RECHARGE
THE BACKUP BATTERY AND MAINTAIN
CORRECT OPERATION.
The Strobe Alert System is designed to alert you
with a visual indication from the Strobe. Residents
who are asleep or under the inuence of alcohol
or drugs may not see the Strobe. Make sure the
Strobe is not obstructed.Test and check that you
can see the Strobe in all positions in the room in
which it is located.
The Strobe Alert System employs the latest
technology and is independently tested as being
compliant with the applicable clauses of relevant
British and European Standards. However, as
with any electronic product, it might fail and may
not give an indication of smoke or CO within
sufcient time to alert you of the danger and
provide adequate time for your escape. In order
Table des matières
Autres manuels FireAngel Produit de sécurité domestique
Manuels Produit de sécurité domestique populaires d'autres marques

Hydreon
Hydreon FakeTV FTV-10 Manuel utilisateur

KIDPRO
KIDPRO Monofilament net Dimensions et guide d'installation

Fiessler
Fiessler ESPE Type 4 Manuel utilisateur

Maretron
Maretron MD-6517-N Manuel utilisateur

LST
LST MGE8-1 Manuel utilisateur

P3 International
P3 International Mini Bug Detector P7050 Manuel utilisateur