FingerTec Kadex Manuel utilisateur

12-01-01 SUN
support@fingertec.com
Kadex
Card Reader for
Time Attendance & Door Access ControlSystem
User Guide

5-6 Chapter 1 • GETTING STARTED
Viewing the User Guide in the Internet
Terminal Included Accessories
Included Printed Materials
Activating Terminal
Registering Terminal
7-9 Chapter 2 • BASICS
Introduction to Products
Overview
Power On/Off Button
Keypad
Battery
Date/Time
Voice Control
Turn On/Off
Adjust Volume
Security Features
Admin Affirm
Tamper Switch
Cleaning Terminal
Restarting and Resetting Terminal
Restart the Terminal
Reset the Terminal
10-13 Chapter 3 • CONNECTION
– SYNCING TERMINALS
Installations
Communications
USB Port
TCP/IP Port
Power Supply Port
RS232/RS485/Wiegand Connection Port
Access Control Port
Bell Port
Checking the Genuine TCMS V2
Installation and Setup of TCMS V2
Connecting The Terminals to TCMS V2
Determining Terminal Number
Using TCP/IP
Using RS232
Using RS485
Using USB to Download/Upload Data
Communication
Key
CONTENTS
15-16 Chapter 4 • USER
Enrolling User
Card Enrollment
Password Enrollment
Card and Password Enrollment
Types of Verification Method
Adding User Information
Deleting User
Access Level/Privilege
17-20 Chapter 5 • SYSTEM
General Settings
Adjusting Date/Time
Date Format
System Language
Voice
Volume (%)
User Interface Style
Button Beep
Defining Work Codes
Update Firmware
System
Information
Number of Users in the Terminal (User
Count)
Quantity of Attendance Log Saved in the
Terminal (Att Log)
Number of Administrator Registered in
the Terminal (Admin Count)
Transactions Done by Admins in the
Terminal (S Logs)
Free Space Information (Free Space)
Device Information (Dev Info)
Log Information (Log Opt)
Alarm Super Log
Alarm Attendance Log
Interval Time to Check for Updates
21 Chapter 6 • DATA
Deleting Transaction Logs
Deleting All Data
Managing User Privilege
Resetting to Factory Settings

22 Chapter 7 • USB
Understanding the Need for USB Flash Disk
Type of USB
Downloading Attendance Logs
Downloading User Data
Uploading User Data from USB to Terminal
Uploading Short Messages
23-26 Chapter 8 • ACCESS
Using The Terminal as Door Access
Access Options
Time Zone
Grouping
User Account Options
Access
Combination
Lock
Door Sensor Delay
Door Sensor Mode
Door Sensor Alarm
Turning Off Alarm
Duress Options
Help Key
Password Trigger
Trigger Methods
Alarm Delay
Alarm Count
Group Verification Type
27 Chapter 9 •
RFID CARD FUNCTION
Enrollment of RFID Card
Verification Using RFID Card Only
Multi Verification Methods Using RFID
Deleting RFID Card
Changing Card ID
28 Chapter 10 •
HID CARD FUNCTION
Registering HID Card
Deleting HID Card
29 Chapter 11 • AUTO TEST
Who Should Do The Auto Test?
Run All Tests At Once
FLASH Test
LCD Test
Voice Test
Key Test
RTC Test
30 Chapter 12 •
TROUBLESHOOTING
“Unable to Connect” Appears
“Admin Affirm” Appears
The LED is Blinking All The Time
RFID Card Doesn’t Respond
No Sound
31 Chapter 13 •
OTHER RESOURCES
Information About FingerTec
Copyright Notice & Disclaimer

5
USB Extension
To connect to the USB port of
a computer for uploading and
downloading of data.
Screwdriver
Use the screwdriver to open the
back plate of the terminal and
to install the back plate against
a wall.
TCP/IP Connector
Connecting the network cable
from a PC or Network switch
to a TCP/IP connector at the
terminal.
TCP/IP Cable
Connecting terminal for
Ethernet connection.
A Packet of Bolts
Use the screws to hold the
back plate of the terminal
against a wall.
RFID Cards (5 pieces) /
HID/MIFARE Cards (1 piece)
For card enrollment and
verification.
Door Accessories Cable
Cables for 12V door lock, push
button, 12V alarm, door sensor
and 12V door bell, for door ac-
cess.
RS232/RS485/Wiegand
Output Cable
For serial cable connection and
Wiegand Output connection.
Power Supply Cable
To connect the terminal to a
12V power supply.
12-01-01 SUN
support@fingertec.com
CONTENTS
1• GETTING STARTED
Viewing the User Guide in the Internet
The User Guide is available in the package when you purchase the terminal. The User
Guide is also available online at fingertec.com and user.fingertec.com. Choose the lan-
guage that you prefer for your online User Guide.
Terminal Included Accessories

6
8
Settings of Working Time &
Group
9
Assign Users To Wo rking
Group
For Time Attendance Functions
(Skip steps 8 & 9 if you are NOTusing time attendance functions)
5
6
7
4
TCMS
V2
Quick Start Guide
For more info go to http://user.fingertec.com
TCMSV2 Installation
Communication
Settings TCMS V2 Initial Settings
terminal to computer installed
with TCMS V2
Download Fingerprint
Tem plates
User Information
Fillup user information in TCMSV2
123
456
78
0
9
ESC
OK
MENU
TCMS
V2
TimeControlManagementSystem-V2
SOFTWARE
INSTALLATION
*Refer to TCMS V2
Manual
SOFTWARE
SETTINGS
*Refer to
TCMS V2
Manual
SOFTWARE
SETTINGS
*Refer to
TCMS V2 Manual.
SET ALL if using
both functions.
CONTENTS
Included Printed Materials
• FingerTec Comprehensive DVD (with Product Code and Activation Key)
• Quick Start Guide
• Pamphlet
• User Enrollment Template Form
• Warranty Card
Activating Terminal
To activate terminal, connect the terminal’s power adapter to a standard power outlet
and turn it on with the power. To download the data from the terminal, you need to have
the product key and activation code for the TCMS. The product key and activation codes
can be retrieved on top of the TCMS V2 manual booklet.
In case you lose TCMS V2 product key and activation code, go to user.fingertec.com/re-
trieve_key_user.php for retrieval.
Registering Terminal
Make sure that you register your terminal’s warranty with us at fingertec.com/ver2/eng-
lish/e_warranty.htm.

7
12-01-01 SUN
support@fingertec.com
L.E.D Display
LCD Screen
Keypad
Card Induction
Area
USB
Port
Reset Button
Speaker
CONTENTS
2 • BASICS
Introduction to Products
The terminal for time attendance and door access system supports RFID card ID, 5-digit
password or combination of both. It works with security alarm system to alert users in
cases of break in and when the duress function in the terminal is used. The terminal can
integrate with a fire alarm system to unlock all doors when the fire alarm is triggered.
The terminal communicates with a computer via TCP/IP and it allows data transfer to be
done with USB flash disk to eliminate extra wiring.
The terminal complies with international standard of CE & FCC, our testament to safety
& quality.
Overview
ITEM FUNCTION
LCD Screen Displaying status of terminal, day, date and time.
LED Display Green LED – The terminal is working fine and it is in standby mode.
Red LED – There is an error at the terminal that requires checking.
For first time use, the terminals need to be charged fully to avoid
having the red light blinking.
Keypad To input instructions into the terminal and to allow configuration.
RFID Card Induction Area Area that reads RFID cards.
USB Port To upload/download users information, password and transaction
logs via USB flash disk.
Speaker For terminal voice emission.
Reset Button To restart the terminal as and when required.

8CONTENTS
Power On/O Button
There is no power button available. Restart the device using the reset button shown on the
bottom of the terminal.
Keypad
You can insert inputs into the terminals through the
keypad. It contains numbers from 0-9, an OK button,
an ESC/Cancel button, a Scroll up/down button, a
doorbell button and a Menu button.
Battery
The terminals operate using power supply from a standard power outlet.
Mini UPS: Mini UPS 12V can also be used to provide power supply to turn on the termi-
nals. Refer to accessory.fingertec.com for more information about accessories.
Date/Time
The terminals displays the date and time at the home screen. Choose the date and time
format based on your preference. Press Menu > Options > Systems Options > Date/Time
> set your time and save.
To change the date format: Press Menu > Options > Systems Options > Fmt > Deter-
mine the date format based on your preference.
Voice Control
Voice Control lets you control the level of volume emitted by the terminal.
TURN ON/OFF
The system lets you turn on/off the voice based on your preference. Press Menu > Op-
tions > System Option > Adv Option > Voice > Y/N.
ADJUST VOLUME
The default volume of the terminal’s voice is 67. The volume can go as high as 100 and as
low as 0. To sustain the performance of the speaker, it’s recommended to stay at range
60-70. To adjust the volume Press Menu > Options > System Option > Adv Option > Adj
VOL (%) > adjust accordingly .

9
CONTENTS
Security Features
Security features help protect the information in the terminal from being accessed by
unauthorized individuals.
ADMIN AFFIRM
Register an administrator into the system by enrolling or a password to a user ID. Press
Menu > User Manage > Enroll Admin > Choose enrollment method > Perform enrolment
and Save. After enrolling an administrator, the main menu can only be accessed by the
administrator.
TAMPER SWITCH
The terminals come with a tamper switch located at the rear of the terminals. During
installation, the tamper switch is compressed against the back plate. Any attempt to dis-
mantle the terminal will trigger an alarm and a “System Broken” message will be dis-
played on the panel.
Cleaning Terminal
CLEANING THE BODY
Use a dry cloth to clean the terminal’s body. Do not use any liquids, household cleaners,
aerosol spray, solvents, alcohol, ammonia and abrasive solutions to clean the body of the
terminal because it could damage it.
Restarting and Resetting Terminal
If a feature isn’t functioning as it should, try restarting or resetting the terminals
RESTARTING THE TERMINAL
Push the On/Off button or “reset button” on the terminal to restart the terminal. If you
can’t restart the terminal, or if the problem persists, you might want to reset.
RESETTING THE TERMINAL
Press Menu > Option > System Option > Adv Opt > Reset terminal. Resetting of the termi-
nal will cause all your settings to return to its original factory settings. Make sure that you
have backed up all data before you proceed.

10
Back Plate
4 feet / 1.2 meter
(recommended)
CONTENTS
3 • CONNECTION – SYNCING TERMINALS
Installations
FingerTec terminals offer several connections for power and communications. Installa-
tions of FingerTec time attendance terminals are simple.
MOUNT ON WALL
Attached the back plate on the wall securely and attach the terminal to the back plate
when mounting it on the wall.

11
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
ALM+
ALM-
NC
COM
NO
BUT
GND
SEN
BEL+
BEL-
GND
+12V
DC12V
Power Supply
For NC
or NO
door
lock
system
BEEP
GLED
RLED
INWD0
INWD1
GND
+12V
Wiegand
IN
Power
OUT
3rd party
controller
with 26 bits
wiegand
output
485+
485-
485+
485-
RX+
RX-
RX+
RX-
1. RS485 Single Connection
RS232/RS485
Data Converter
RS232/RS485
Data Converter
2. RS485 Network Connection
485+
485-
RJ45-1
RJ45-2
RJ45-3
RJ45-6
WD0
WD1
GND
RXD
TXD
GND
485+
485-
TCP/IP
Wiegand
OUT
RS232
3rd party controller
with 26 bits
wiegand input
RS232
cable
TCP/IP
RS485
CONTENTS
Communications
Connection points for power and communication are available on top of the terminals.
Refer to the following diagrams for the terminals you require.
Autres manuels pour Kadex
2
Table des matières