FILTRABOX MICRO Manuel utilisateur

USER MANUAL

1

2
TABLE OF CONTENTS
i. SPECIFICATIONS –pg. 3
ii. MACHINE DIAGRAM –pg. 4
iii. ASSEMBLY INSTRUCTIONS –pg. 6
iv. INSTALLATION INSTRUCTIONS –pg. 7
v. QUICK START INSTRUCTIONS
a. CALIBRATION –pg. 8
b. AIRFLOW SETTING –pg. 9
vi. FILTER REPLACEMENT INSTRUCTIONS
a. CAPACITY WARNING –pg. 11
b. FILTER CHECK FEATURE - pg. 12
c. REPLACING THE DUST PRE-FILTER - pg. 13
d. REPLACING THE DUST HEPA FILTER - pg. 13
e. REPLACING THE OXY-CARBON GAS FILTER - pg. 14
vii. MENUS
a. FILTER CHECK –pg. 15
b. NEW APPLICATION CALIBRATION –pg. 15
c. SERVICE MENU –pg. 15
viii. SUPPORT –pg. 16
ix. WARRANTY –pg. 17

3
SPECIFICATIONS
Micro
Voltage
120V
Frequency (Hz)
50 / 60
Wattage (kW)
0.7
Blower Type
1x Brushless
Length (mm/inches)
432/17
Width (mm/inches)
254/10
Height (mm/inches)
660/26
Weight (Kg/Lbs)
36.3/80
CFM
128
Pressure: inH2O
80 (High Pressure)
Construction
Steel
Design
Independent Filters
Operating Decibels
50
Display/Control
LCD/Push Button
Flow Control
Auto-Compensation
Warranty
1 year
Pre-Filter
Rigid Aluminum Pre-Filter
Media: F9 Glassfiber
Filtration Area: 3m²
FIL-P-MC-426
HEPA Filter
Rigid Aluminum HEPA Filter
Efficiency: 99.999% @ 0.3
Media: Glassfiber
Filtration Area: 3m²
FIL-P-MC-426
Gas Filter
OXY-CARBON Filter
Dual Action: Oxidation/Adsorption
Carbon Weight: 20 lbs
FIL-G-MC-406

4
MACHINE DIAGRAM

5
MACHINE DIAGRAM –USER INTERFACE

6
ASSEMBLY INSTRUCTIONS
UNPACKING
! Useful Tip: The Filtrabox is shipped in custom packaging for maximum
protection during transport. Consider keeping the packaging should you wish to
ship the product again.
! Attention: The OXY-Carbon Gas Filter is HEAVY. This filter weighs
approximately 20lbs. Take appropriate care and precaution when lifting the
filter.
Remove all the packaging and place all the parts on the floor. Take inventory of the parts included with
your kit:
BOX 1:
1. Filtrabox Micro Fume Extractor with Pre-Installed Filters:
a. Dust Pre-Filter
b. Dust HEPA Filter
c. OXY-Carbon Gas Filter
2. User Manual and Quick Start Guide
3. Screws and Tool for Threaded Inlet
BOX 2:
1. Power Cord
2. Threaded Inlet
3. Flex Hose 4” with Hose Clamp
a. Specific hose adapters may also be provided
The Filtrabox Micro is packaged without the Threaded Inlet to protect it in shipping. Follow the
Installation Instructions on the next page to get started.

7
INSTALLATION INSTRUCTIONS
! Important Note: The Calibration system will take all the bends and restriction
of the flex hose into account and provide optimal performance.
1. Install the Threaded Inlet onto the Lid Module using the three screws and the tool provided
with the user manual. See figure below.
2. Screw the supplied 4” Flex Hose onto the inlet of the machine. Insert the hose into the threads
and turning anti-clockwise until it can longer turn. See figure below.
3. Secure the other end of the supplied 4” Flex Hose to your laser with the supplied Hose Clamp.
4. Place the Filtrabox Micro in the final position that it will be regularly used. This is important for
Calibration as the system will take all the bends and flow restrictions of the flex hose into
account and provide optimal performance.
5. Install the supplied power cord onto the back of the Filtrabox Micro and turn it on with the Main
Power Switch located to the right of the User Interface.

8
QUICK START INSTRUCTIONS:
CALIBRATION & AIRFLOW SETTING
SAFETY
! Before connecting the device to a power source, ensure that the main power
switch in the rear of the device is in the off position “0”.
! Avoid plugging or unplugging the unit while it is powered ON ( “I” ).
CALIBRATION INSTRUCTIONS
! Device must be calibrated to your specific laser engraver to function properly.
! Failure to calibrate the device prior to usage may significantly reduce the life of
your filters.
1. Hook up the Filtrabox fume extractor to the Laser Engraver, with the supplied hose or with
the hose you intend to permanently use for the application. Arrange the laser, Filtrabox and
the hoses into their desired locations. ! This is important because the calibration process
takes the restrictions caused by the bends in the hose and positioning of the equipment into
account.
2. Press OK to confirm that the Filtrabox and laser engraver are connected in their desired final
positions; this will initiate the automatic calibration procedure.
3. The Filtrabox will display various screens as the calibration steps are conducted; this will
take a couple minutes. At this point no input is required. When the calibration is finished,
the machine will display the main screen where the flow setpoint can be adjusted with the
up/down keys See AIRFLOW % SETTING to determine how to set your machine.

9
AIRFLOW % SETTING
! USEFUL TIP 1: Use the “4-6 second rule” to determine adequate evacuation of
the laser; the “Airflow %” setting should be set to the value where you can
observe full evacuation of the fumes from the laser enclosure within 4-6 seconds
from the instant that the laser stops engraving/cutting. Check by opening the laser
top cover 4-6 seconds after the laser stops. There should NOT be any fumes visible.
If you cannot achieve the 4-6 second rule, you can try the 6-8 second rule, which is
also acceptable.
Set your “Airflow %” to the lowest possible setting that will adequately evacuate
the fumes from your laser. This ensures that you are using your filters to their
maximum potential which minimizes costs.
! USEFUL TIP 2: Start by setting your Filtrabox at 35% for a small sized laser and
incrementally increase, using the 4-6 second rule to determine the minimum
adequate evacuation setting.
SETTING THE AIRFLOW% SETTING
1. The Status screen is the first screen shown once the device has finished calibrating or finished
booting up. The device will display the current flow setting.
2. Turn on the blower by pressing the POWER key.
3. Set the “Airflow %” to the desired starting point by pressing the +or -keys.
! USEFUL REMINDER: Start by setting your Filtrabox at 35% for a small sized
laser and incrementally increase, using the 4-6 second rule to determine the
minimum adequate evacuation setting.
4. Start engraving/cutting on the most smoke/odor generating substrate you will typically use.
5. Adjust the “Airflow %”until you see significant movement of the fumes towards the laser intake
vents.
6. Check to see if you have achieved the adequate evacuation flow using the 4-6 second rule or the
6-8 second rule.
7. Continue adjusting your flow until you are satisfied with the performance. The “Airflow %”
value will be automatically saved to memory.
8. When the laser is not in use, press the POWER key to turn the blower(s) off.