1. XL4800TM EZ HOOKUP
ZONE HOOKUP
The XL4800EZ contains 16 zones connected as follows;
KEYPAD CONNECTIONS
ZONE TERMINALS ZONF TFRMINALS
1 1 & 2 [Delay] 9 38&39 [Per/m.]
2 3 & 2 [hx FO//j 10 39 & 40 [Pedm.]
3 4 & 5 [Perim.] 11 41 842 [Perim.]
4 6 & 5 [Perim.] 12 42 & 43 [Perim.]
5 7 & 8 [Perim.] 13 44 8 45 [Perim.]
6 9 & 8 [Perim.] 14 45 & 46 [Perim.]
7 lO& 11 [Perim.] 15 48 & 49 [Perim.]
8 12 8 11 [Fire] 16 48 & 49 [Aud. Panic]
The factory default values for each zone is displayed above, and
each zone can be programmed for any of the following types; Delay,
Interior, Interior Follower, Perimeter, Silent Panic, Audible Panic,
Day Trouble, 24 Hour Trouble, or Fire Zone. Each of the zones can
be EOL supervised using the 2.2K EOL resistors provided. The zone
programming questions are questions 35 and 36 within the LCD
keypad programming sequence.
The XL4800 keypads are connected to the control panel with four
conductor cables to terminals 13 through 16. Attach each keypad
used within the system to the terminals as follows;
T13 Red ( + voltage)
T14 Green
T15 Yellow
T16 Black ( - voltage)
The keypads should be connected in parallel at the control panel
with wire runs not to exceed 3000 feet using 22 gauge wire. Keypads
can also be daisy chained, however the maximum sum of the wire
run should not exceed 5000 feet from the control panel using 22
gauge wire. For example, if one keypad is 500 feet from the control
panel with another keypad run 200 feet from the first keypad, this
wire run would be considered 1200 feet (500 to first keypad + 700 to
second keypad).
The available keypad power from connections 13 and 16 is restricted
to 250 ma. Since each keypad draws approximately 60 ma, a
maximum of 4 keypads can obtain their power from these terminals.
Additional key pads must obtain their power from the other auxiliary
panel outputs(if sufficient capacity is available) or an external power
supply. Note: All keypads must be connected to terminals 14 and 15
regardless of where they obtain power.
Auxiliary power (13.8VDC regulated) can be obtained from three
different outputs of the XL4800 EZ panel. The total regulated output
oower from the XL4800 EZ is 900 ma with oower available as
iollows;
TERMINALS MAX. CURRENT APPLICATION
13 (+) 8. 16(-) 250 Ma. Keypads
17 (+) & 16(-) 500 Ma. Misc. (Passives etc.).
33 (+) & 32(-) 150 Ma. Smoke Detectors
NOTE: Terminal 35(+) is internally connected to 17 (+). The
maximum current available from both of these points added together
is 500mA. Power can be obtained from any of these connections
provided that the total does not exceed the rated capacity of the
terminals. Consult the specifications for the devices being connected
to determine the power requirements for your installation.
AUXILIARY POWER
STAR XL4800 EZ INSTALLATION INSTRUCTIONS Page 1