Farm King 1066 Manuel du produit

OperatOr and parts Manual
112010
Conventional Auger
Model 1066 & 1076
SZ000252


3
Table of Contents - 1066 & 1076 Conventional Auger
Introduction .................................................................................................................................4
Safety ............................................................................................................................................5
• Safety ................................................................................................................................5
• General Safety ..................................................................................................................5
• Operation Safety ..............................................................................................................5
• Transport Safety ...............................................................................................................6
• Electrical Safety ................................................................................................................6
• Safe Operation Instructions ............................................................................................6
Assembly ......................................................................................................................................8
• 4 and 6 Bolt Hub Assembly ...........................................................................................10
• Head Drive Assembly ....................................................................................................10
• Assembly Instructions ................................................................................................... 11
• Assembly Instructions - PTO Drive ...............................................................................15
Parts ............................................................................................................................................16
• 1066 and 1076 Parts........................................................................................................16
• Decals ..............................................................................................................................21
• PTO Drive ........................................................................................................................22
• 6005 Gear Box ................................................................................................................23
Warranty ....................................................................................................................................24
Manufacturer’s statement: for technical reasons Buhler Trading Inc. reserves the right to modify
machinery design and specifications provided herein without any preliminary notice.
Information provided herein is of descriptive nature. Performance quality may depend on grain
type, grain moisture, auger elevation and other factors.
Table of Contents

4
Introduction
To the owner
Thank you for purchasing a Farm King 1066 or 1076 Conventional Auger.
Farm King Conventional Augers have been designed to provide many years of profitable and
dependable service. To assure maximum performance of your auger, it is mandatory that you
thoroughly study the operator’s manual and follow its recommendations. PLEASE EXAMINE
YOUR UNIT CLOSELY AND READ THE ASSEMBLY INSTRUCTIONS TO SEE THAT YOUR UNIT IS
PROPERLY ASSEMBLED. Proper operation and maintenance are essential for safety, to maintain
performance, and to maximize the life of the auger. When ordering parts or inquiring about the
auger, you must include the serial number which is located on the second upright of the lower
truss support.
It is the owner’s responsibility to:
Operate and maintain this auger in a safe manner and in accordance with all applicable local, state,
and federal codes and/or laws.
Make sure each and every operator has read the operator’s manual and thoroughly understands
safe and correct operating procedures.
Make sure unauthorized people do not operate or are not in the vicinity of the auger while it is in
operation.
Maintain the auger in accordance with the maintenance schedule in this manual. Furthermore, as
additional technology becomes available, the owner is responsible for improving the safety and
reliability of the system.
Fulfill all warranty obligations so as not to void the warranties. Verify the unit is warranty registered
prior to making any warranty claims. The warranty section at the back of this manual outlines the
warranty policy of Farm King.
Abuse or modifications to the auger that change the performance other than original factory
specifications void the warranty.
Farm King reserves the right to make product improvements to the equipment at any time. It shall
not be obligated to make such changes to machines already in service.
*The owner, manager and/or operator is responsible for safe, accurate operation and maintenance
of the Farm King 1066 or 1076 Conventional Auger.
Introduction - 1066 & 1076 Conventional Auger

5
Safety
Safety Instructions
An Operator‘s Manual is furnished with each grain auger. Additional or replacement manuals
are available. Do not operate the unit before reading and understanding the Operator‘s Manual.
Understand the operating procedures below to avoid personal injury or death.
The alert symbol is used throughout this manual. It indicates attention is required and identifies
hazards. Follow the recommended precautions.
The safety alert symbol means…
ATTENTION! BECOME ALERT! YOUR SAFETY IS INVOLVED!
General Safety
An auger can collapse and fall on the operator or bystander causing serious injury or death.
Always support the discharge end when the following conditions occur:
• While unit is in operation.
• When dismounting the undercarriage.
The accidental tipping or upending of an auger may cause serious injury or death to the operator
or bystanders. When the grain flow is shut off to the auger an overbalance situation can occur,
suddenly raising the intake auger. Adequate anchorage of the intake end or support from bin is
required at all times, especially in the following conditions:
• While unit is in operation.
• When moving the auger.
• When raising or lowering the auger.
• Maximum elevation is determined by interference between track car and auger structure. The
operator must stop raising the auger before track car reaches the end of the track. Continued
lift will cause failure of the winch, lift cable or auger supports, causing auger to collapse,
which can result in serious injury or death.
Contact with rotating flighting will cause serious injury or death.
• Do not stand on the intake cage.
• Keep hands, feet and clothing away from the intake and discharge flighting.
Operation Safety
Intentional or accidental contact with moving parts may result in a serious injury or death. Observe
the following operating procedures.
• Keep all safety devices in place.
• Do not adjust, service, lubricate, clean, unclog or move the mechanism until all power is
shut off.
• Keep hands, feet and clothing away from moving parts while in operation.
• Keep off the equipment at all times.
• Make certain that everyone is clear of the equipment at all times.
• Make certain that everyone is clear of the equipment before applying power.
• Keep children, visitors and all untrained personnel away from machine while in operation
Safety - 1066 & 1076 Conventional Auger

6
Transport Safety
Care must be used when moving or transporting the auger. Accidental tipping or upending of an
auger can occur and may cause serious injury or death to the operator or bystanders.
• Never move the auger manually.
• Be sure auger is empty before attempting to move.
• Never push on the undercarriage of the auger.
• Tow the auger at slow speed and in the down position.
• Always test the intake end of the auger for downward weight when attaching or releasing.
• Never raise the hitchpoint higher than the vehicle‘s tow bar.
Electrical Safety
Contact with overhead wires may cause electrocution of the operator or bystanders. Contact with
overhead obstructions may cause collapse or tipping of the auger or may cause the overhead
obstruction to fall. In both cases the operator or bystander can be seriously injured or killed.
Observe the following:
• Tow the auger at slow speed and in the down position.
• Raise or lower the auger slowly.
Electrical malfunction can cause electrocution of the operator or bystanders.
Observe the following rules.
• Disconnect power and electrical driven units before resetting motor overloads.
• Do not operate electric motor equipped units until unit is properly grounded.
Safe Operating Instructions
There are several decals on the grain auger and its attachments with safety instructions.
Read and understand these safety alerts before operating.
The shielding has been removed in some of the illustrations for parts demonstration only.
Install all shields before operating the unit.
DANGER
Electrocution hazard. This machine is not insulated. Keep away
from overhead electric wires and devices. Electrocution can occur
without direct contact. Failure to keep away will result in serious
injury or death.
DANGER
Maximum elevation is determined by interference between track
car and auger structure. The operator must stop raising the auger
before track car reaches the end of track. Continued lift will cause
failure to the winch, lift cable or auger supports, causing auger to
collapse, resulting in serious injury or death.
Safety - 1066 & 1076 Conventional Auger

7
Safety - 1066 & 1076 Conventional Auger
DANGER
Upending hazard. 1 - Never mover the auger manually - use a
vehicle. 2 - Always have downward weight on the intake end of
the auger. 3 - Always test the downward weight before releasing
the auger from the vehicle or hold down. 4 - Always lift the intake
slowly and keep it no higher than the tractor tow bar when
attaching and releasing it. 5 - Never push on the undercarriage.
6 - Never move the auger, with grain, in the auger tube. 7 - Always
lower the auger to transport postion before moving. Failure to
follow these guidelines may cause upending, which may result in
serious injury or death.
Shear bolt failure indicates an overload on the auger.
To remedy the problem:
1. Reduce flow into the intake of the auger. Wet grain requires more power to operate the auger.
The flow must be reduced in wet grain to prevent plugging and/or shear bolt failure.
2. Make certain the auger is running at the correct speed. Run the tractor PTO at 540 RPM for the
correct flighting speed. Slowing the auger will allow it to overload and plug.
3. Check for foreign objects (sacks, cans, rags, etc.) in the tube. Objects may go part way up the
tube and wedge between the flights, blocking the grain flow.
ALERT
Do not operate the auger empty during the break-in period.
For the best results, do not full feed the intake for the first 500
bushels. After break-in, never run auger at slow idle when full
feeding the auger.

8
Assembly - 1066 & 1076 Conventional Auger
1066 Trussing
1076 Trussing

9
Assembly - 1066 & 1076 Conventional Auger
Keep all shields in place during operation.
NOTE: Use a 3/8" x 1-1/4" Grade 2 shear bolt.
Using other than a Grade 2 bolt may result in
damage to the drive components.
1066 Model
1076 Model

10
Assembly - 1066 & 1076 Conventional Auger
Keep all shields in place during operation.
4 and 6 Bolt Hub Assembly
Head Drive Assembly
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Farm King Outils