FA-TECH VEGA MB-97 Manuel utilisateur

US Version
Page of1 26
VEGA MB-97
Operator’s Manual

FATech Diagnostics Italia
Corporate Headquarters
37, Via Sisto V
63074, San Benedetto del Tronto (Italia)
Tel.+39 0735 592648
User Resources and Customer Support
Contact your FATech Diagnostics Italia representative for customer support. For the latest informa-
tion on FATech Diagnostics Italia products and services, please visit the FATech Diagnostics Italia
website at: www.fatechdiagnostics.com
Scope
This document contains basic information on the use and operation of VEGA MB-97 Cassette
Printer and assumes you have received basic training on the instrument. Please contact your FAT-
ech Diagnostics Italia representative for information not provided in this manual. This manual does
not provide instructions for the installation or upgrade of hardware.
Introduction
The VEGA MB-97 Cassette Printer is designed to generate a unique identification mark in the
form of high-resolution linear bar codes, two-dimensional bar codes and text onto VEGA MB-97
Cassettes hence reducing errors due to misidentification of cassette blocks or specimen slides
caused by illegible handwriting. The VEGA MB-97 Cassette Printer comes equipped with 6 maga-
zines with a capacity to accommodate 60 Laser Cassettes. Optional additional magazines are
available for easy cassette style or color changes.
Intended Use
The VEGA MB-97 Cassette Printer is intended for imprinting identification marks on FATech Tis-
sue Cassettes for histology.
Installation Procedure
The VEGA MB-97 Cassette Printer and associated software must be installed, and instrument
performance is to be verified, at the customer site by trained FATech Diagnostics Italia representa-
tives.
Relocation Procedure
Contact your FATech Diagnostics Italia representative before relocating your VEGA MB-97 Cas-
sette Printer.
Disclaimers
This manual is not a substitute for the detailed operator training provided by FATech Diagnostics
Italia, or for other advanced instruction. A FATech Diagnostics Italia representative should be con-
tacted immediately for assistance in the event of any instrument malfunction
Page of2 26

Table of Contents
Section 1 | Safety 4...............................................................................................................................
Instrument Compliance 6...................................................................................................................
Component Location 7..........................................................................................................................
Section 2 | System Specifications 9......................................................................................................
Section 3 | VEGA and Cassette Printing Software 10...........................................................................
Launching VEGA Software 10...........................................................................................................
Loading Cassettes 12.....................................................................................................................
Load HUB button 12.......................................................................................................................
Extra hoppers carousel 12.............................................................................................................
Printing Cassettes 13........................................................................................................................
Prioritizing Cassettes 13....................................................................................................................
Adding Cassette 13........................................................................................................................
To add or edit cassette click on “HUB” and you will get a new screen “Modify cassette-maga-
zine”. 13..........................................................................................................................................
Section 4 | Creating a new User 15......................................................................................................
Generate a copy of the parameter list 16..........................................................................................
Data Export 16...................................................................................................................................
Section 5 | Troubleshoot cassette jam 17.............................................................................................
Section 6 | Marked cassettes dispensing methods 18..........................................................................
Section 7 | Maintenance 19...................................................................................................................
Removal of marking dust. 19.............................................................................................................
LASER LENS Cleaning every 6 months. 19......................................................................................
Mechanical test every 6months. 19...................................................................................................
APPENDIX A | LASER SAFETY 20......................................................................................................
Laser Hazard Classifications 20........................................................................................................
APPENDIX B | SYMBOLS DEFINITION 23..........................................................................................
APPENDIX C | LABELS PLACEMENT 24............................................................................................
WARNING FOR USERS DIODE Lifespan 24...................................................................................
Page of3 26

Section 1 | Safety
Caution Symbol
Optical Laser Safety
Operational Safety
The CAUTION symbol appears on the instrument's product label to remind you
of the necessity to refer to this guide, or other documentation, that outlines labo-
ratory practices required by your facility and local regulatory agencies. Failure to
comply with these requirements may result in a hazardous condition. This may
also nullify the instrument warranty.
The VEGA MB-97 Cassette Printer should not be used in any way not specified
by FATech Diagnostics Italia. Otherwise, the protection provided by the instru-
ment may be impaired.
Note: Refer to Appendix B: Symbol Definitions for additional symbols
INVISIBLE LASER RADIATION AVOID EYE OR SKIN EXPOSURE TO DIRECT
OR SCATTERED RADIATION
CLASS 1 LASER PRODUCT, USING
The laser beam Exits the Final lens 6.6 inches (17cm) above the cassette while it
is in the marking position
Never attempt to operate the VEGA MB-97 Cassette Printer without the protec-
tive covers in place.
Never attempt to override any of the safety interlocks on the instruments.
Never attempt to dismantle or repair the laser head. In case of malfunction con-
tact a FATech Diagnostics Italia Service representative.
Any of the actions mentioned above may result in permanent eye or skin dam-
age. Refer to Appendix A for more information on laser safety.
Routine of VEGA MB-97 Cassette Printer is required for maintaining system in-
tegrity and proper operation. Maintenance must be carried out as specified in
this manual. Refer to Section 9 | Maintenance, for more information.
Do not attempt to install or re-locate the VEGA MB-97 Cassette Printer . Doing
so may result in corruption, of data and/or malfunctioning instrument. For Cas-
sette Marker installation contact a FATech Diagnostics Italia service representa-
tive
Locate the VEGA MB-97 Cassette Printer only on a sturdy flat surface.
VEGA MB-97 Cassette Printer is intended for Indoor use only. Maximum oper-
ating altitude is 9,840 ft. (3000m), operating temperature 59 to 95 degrees F, (5
to 35 degrees C), 80% maximum relative humidity, rated 100-240Vac (max range
of 90 to 264Vac), over-voltage category, II, pollution degree 2, IPX0
Please be aware that some discoloration to the FATech Cassettes can occur
when they are subjected to reagents containing picric acid, e.g. Bouin’s Fixative.
Page of4 26

Electrical Safety
Mechanical Safety
FCC
Please be aware that degradation or loss of text printed text on FATech Cas-
settes may occur when they are subjected to solutions containing strong acids
for extended periods of time.
Decalcification processes of tissue in the FATech Cassettes involving strong
acids such as hydrochloric acids or nitric acids should always be validated by the
users prior to implementation.
The main power cord for the VEGA MB-97 Cassette Printer must be plugged into
earthed outlet only. Only use the power cord provided with this product
Be sure to position the VEGA MB-97 Cassette Printer to allow for easy removal
of the main power cord from the back panel.
Never attempt to operate the VEGA MB-97 Cassette Printer without the protec-
tive covers in place.
Never attempt to override any of the safety interlocks on the instruments.
Apart from a class 4 laser, the instrument contains moving machinery that may
cause damage to the user if the above advices are not followed.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful inter-
ference in which case the user will be required to correct the interference at his
own expense.
Page of5 26

Declaration of conformity
Déclaration de conformité
Dichiarazione di conformità
FATech Diagnostics Italia, Srl
declare under our sole responsibility that the product,
déclarons sous notre seule responsabilité que le produit,
dichiariamo sotto nostra unica responsabilità, che il prodotto,
VEGA MB-97 Cassette Printer,
to which this declaration relates is in conformity with the following standard(s) or other normative
documents.
auquel se réfère cette déclaration est conforme à la (aux) norme(s) ou au(x) document(s)
normatif(s).
a cui si riferisce questa dichiarazione è conforme alla/e seguente/i norma/e documento/i normativa/
e
Instrument Compliance
FATech Diagnostics Italia herby declares the equipment specified conforms to the Classification(s),
Directive(s) and Standard(s) set forth in this document.
FATech Diagnostics Italia produces laser systems within one of two classes as identified and classi-
fied by theCDRH. These are Class I and Class IV. (see CDRH 21 CFR (J) 1040.1 - 1040 .5). End
user of the equipment should be familiar with ANSI, CDRH and OSHA standards for radiation emit-
ting devices as they apply to them also.
Certifications:
- [Saf] IEC 61010-2-101:2015
- [Saf] IEC 61010-1:2010
-[EMC] EN 61326-1:2012
-[EMC] EN 61000-3-2:2019
-[EMC] EN 61000-3-3:20
-FCC CFR 47 Part 15 Subpart B and ICES-003 Issue 7
Page of6 26
Declaration of Conformity

Component Location
Page of7 26
Laser Cooling Fan grid
Laser Label
Cooling Fan grid
USB Port
Interlock Key
ON/OFF Switch
Power supply socket
Organizer connector
Remote Interlock
- USB
- Interlock Key
- ON/OFF Switch
- Remote Interlock
- Power supply sock-
- Organizer connector
- Green: Loading Hub
- Red Reset unit

LED Indicators
Page of8 26
- Cassette hoppers
- Spare hoppers carousel
- Cassette dispensing chute
- LED Indicator label

Section 2 | System Specifications
VEGA MB-97 PH 6 Cassette Printer
Item
Description
Dimensions
D 60 cm X W 20 cm X H 52 cm
Weight
23.3kg
Laser
YAG Class 4 Sealed Laser 2,2-Watts 1064µm wave-
length
Electrical Requirements
110V-240V 50/60 Hz ±10% output 24VDC 5A
Fuses
120V 4 Amp
240V 3 Amp
Max dBA Sound level
55dBA
Max Power
70W
Over Voltage Category
II
Index Protection
IP55
Hubs (6)
Cassette Capacity
80 Cassettes per Hub
480 Cassettes total
Print Speed
Up to 12 cassettes/minute
Print Resolution
600 dpi
Operating Temperature Range/
Humidity
15°C to 35°C
10% to 80% non-condensing
Barcode compatibility
Data Matrix, QR code, Code 128, Code 29, PDF417
Connectivity to PC
USB
Pollution Degree
2
Maximum Altitude
2500m
Page of9 26

Section 3 | VEGA and Cassette Printing Software
1. Press the power ON button positioned at the rear of the instrument.
2. Press the Emergency button positioned at the left side of the cover.
When the system will be ready the emergency button will turn RED.
Launching VEGA Software
1. Double-click the VEGA icon
2. Enter User Name and Password.
Default values “administrator/administrator”
3. The cassette marker will perform a self-test.
4. SAMLight will launch in the background.
NOTE: You should see the VEGA and SAMLight icons in the taskbar.
Page of10 26
Table des matières
Manuels Équipement de laboratoire populaires d'autres marques

Agilent Technologies
Agilent Technologies 5800 ICP-OES Manuel utilisateur

Endress+Hauser
Endress+Hauser Cleanfit CPA875 Manuel utilisateur

NI
NI PXI-5422 Manuel

Collomix
Collomix Aqix Manuel utilisateur

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series Manuel utilisateur

Ocean Insight
Ocean Insight FLAME-NIR+ Manuel utilisateur











