37-45
46-48
31~39
40~42
49-52
53-54
UPC-A, UPC-A Expand to EAN-13.........................
Codabar..................................................................
13~15 Enable/Disable Barcode Symbology...........19-21
SYMBOLOGIES (GROUP 13 - 30)
FULL ASCII(CODE39)TABLE, FUNCTION
KEY TABLE(GROUP 31 - 42)
APPENDIX
22
Interleaved 2 of 5, IATA, Matrix 2 of 5.....................16
17 Industrial 2 of 5, NEC 2 of 5, Code 11.....................23
24
Code 93, MSI..........................................................18
Standard/Full ASCII Code 39, Code 32..................25
19
20 26
21
Code128, GS1-128, GS1 Databar.......................... 27
22 28
23 UPC-E, UPC-E Expand to UPC-A, UPC-E1...........29
EAN-8.....................................................................
24 30
31
32
33
25 EAN-13, ISBN.........................................................
China Post, Korea Post, Planet, Postnet................
26
27 Australian Post, Other Postal Codes......................
36
30 Codablock A, Codablock F, GS1 Composite...........
35
29
MaxiCode, Aztec, Chinese Sensible Code (Han Xin)..
34
28
PDF417, MicroPDF417, (Micro)QR Code, DataMatrix..
Full ASCII table(Code 39)...........................
Function Key table(Code 39)......................
Appendix 1 Default table........................................
Appendix 2 Barcode test chart...............................
9
LED & Beeper Indication..............................................
6
Reading Mode, Magnetic Switch...............................8
7
4-5
3
2
Send Data Length, Preamble, Postamble................
12
Table of Contents.........................................................
Cloning Mode............................................................
How to set up the parameter........................................
Default, Abort, Check Version, Setup Code Read.....
1
2
13-15
Beep tone, Vibrator, Terminator.................................
3
17
16
4
18
5Code ID, Inverse Barcode........................................
6
10
Symbologies Code Identifier.....................................
Set Code ID....................................................
7~9
Inter-block and Inter-character Delay.....................
11 Keyboard Layout....................................................
Caplock Mode, Numeric Key, HT/CR/ESC Conversion..
12
GENERAL SETTINGS (GROUP 1 - 12)
PREFACE
CONTENTS
10
11

LED & BEEPER INDICATION
Scanner
Status
Blue LED
Beeper
Initializing/
Power-up
Successful
Barcode
Scan
Unexpected
Barcode
Scan during
Configuration
1 Flash
1 Flash
1 Flash
1 Flash
1 long beep
2 beeps
Reads
Configuration
Barcode
1 beep
3 short beeps

CLONING MODE
FORMAT OF CLONING
WHAT IS CLONING MODE?
CLONING duplicates a scanners settings in other scanners. It can
save time when a number of scanners must be programmed to the
same settings.
HOW SHOULD CLONING WORK?
1. Using this guide, make all the necessary settings for one wand.
2. Scan the CLONING MODE bar code shown below.
3. When CLONING MODE is scanned, all setup parameters will be
converted to alphanumeric characters and shown on the monitor.
4. Using a bar code printer, print out all the setup parameters as
Code 39 bar code labels.
5. Scan the printed labels sequentially with each wand to be
programmed.
Figure 1
CLONING MODE
NOTES:
1. All cloning strings are upper case.
2. All cloning strings printed on labels should be the same as those on
the monitor sequentially from first to last.
3. Cloning mode works in Word Note Pad only.
4. Never edit the data on the first row (.A017$). It is an entry command
for cloning.
5. The cloning string’s length can be adjusted by combining multiple
strings into one, or by breaking one string into multiple strings starting
from the second row after “....”. Length must be in sequences of four,
such as 4, 8, 12, 16, 20 (MAX).
6. Be sure to print the dots exactly where they are shown on the monitor.
* Format of Cloning:
1st row >>> “.A017$” ( never edit any data of the first row )
2nd row >>> “....XXXX” you can adjust the String’s Length starting
from the dots “....” forward. The length of the string should
be in 4, 8, 12, 16 or 20 ( MAX )digits.
3rd row ~ so on >>> XXXX
End row - A dot “.” Is the ending of cloning.
XXXX Stands for any string
. A016$

CORRECT SETTING
WRONG SETTING
EXAMPLE :
1. PROJECT ASSIGNMENTS:
1.1. Beep tone: BEEP LOW.
1.2. Capslock Mode: CAPSLOCK ON.
1.3. Reading Mode: CONTINUOUS AUTO OFF.
2. SETTING PROCEDURE:
2.1. Scan BEEP LOW (GROUP 3).
2.2. Scan CAPSLOCK ON (GROUP 12).
2.3. Scan CONTINUOUS MODE (GROUP2).
3. Scan [.A016$] Cloning Mode. All parameters will be output in alphanumeric
characters and shown on the monitor.
4. Print the results shown on the monitor as bar codes with a bar
code printer. The bar codes should be in the Code 39 symbology.
5.
Scan from the first row to the second and so on sequentially,
top to bottom, with the scanner you wish to “clone” these
settings to.
.A017$
....8C06
8D02980A
.
.A017$
....
0604
5A02
5F04
.
4
4
4
4
. (Dot)
.A017$
....06045A02
5F04.
12
4+.(Dot)
. A017$
. . . . 8C06
8D02980A.
.A017$
..
..0604
5A02
5F04
.
Wrong Setting: The string “....”
consists of 4 Dots, located at the
beginning of second row; do not
break the “....” into multiple strings.
Wrong Setting: The string lengths of the
second and third row do not match the
length requirements, because rows should
be in length of four digits.
.A017$
....06045
A025F04
.
Wrong Setting because you add
“....” after .A017$:
The .A017$ is a FIXED parameter to
enter setup procedure. It is an unchangeable
parameter. Never add, delete or rearrange
data from the FIRST row.
.A017$....
0604
5A02
5F04.
9 x
7 x
. (Dot)
X
4
4
4+.(Dot)
CLONING MODE

HOW TO SET PARAMETERS
1. Use the scanner to scan at the bar code representing the function/
parameter you want to set.
2. When you hear two beeps, the new settings have been defined or
updated permanently to the scanner.
Default parameters are indicated in bold type and underlined
characters. The character font is ARIAL BLACK.
Most settings require only a single bar code, but a few need several
different bar codes to be scanned in order to completely define a
setting (i.e Multi-step Configurations). They are:
How do you program a scanner with this user’s guide?
Preamble / Postamble (maximum 16 digits)
Step 1: Scan CLR PRE/POSTAMBLE.
Step 2: Scan PREAMBLE or POSTAMBLE.
Step 3: Scan 1 ~ 16 alphanumeric from Full ASCII table (Group 31-42).
Step 4: Scan PREAMBLE or POSTAMBLE.
Min Length / Max Length
Step 1: Scan MIN LENGTH or MAX LENGTH.
Step 2: Scan two digits from Full ASCII table - Numbers (Group 39).
Step 3: Scan MIN LENGTH or MAX LENGTH.
Set Code ID (Example: Code 39)
Step 1: Scan CODE 39 SET ID from Group 7
Step 2: Scan either one or two alphanumerics (maximum 2 digits)
from Full ASCII table (Group 31-39)
Step 3: Scan CODE 39 SET ID from Group 7
1. The scanner will beep three times as indication that a setting is
not yet complete or unexpected barcode is scanned during multi-step
configuration.
2. If you make a mistake, forget a step, etc., and want to abort the multi-
step configuration, scan RESET/ABORT and start over again.
NOTES:
. P023$
*.P023$*
RESET/ ABORT

SETUP CODE OFF
SETUP CODE ON
. A001$
DEFAULT
GROUP-1
SETUP CODE READ
GENERAL SETTINGS
. A007$
CHECK VERSION
RESET/ ABORT
. P023$
*Reset to factory default
*Check firmware version
*Abort multi-step configuration
*Caution: Scanning SETUP CODE OFF will turn the
scanner into unprogrammable state and the scanner
will not react to any configuration barcode!
*Caution: Before switching to USB VCP, please make
sure you have installed proper driver on PC. The driver
is available for download on website or from your local
distributor.
*Caution: Once disabled, the scanner will output
the original encoded data of the barcodes in Full
ASCII Table - Function/Navigation/Modifier Keys
(Group 53-55).
FUNCTION CODE
CONVERSION
DISABLE
*.C020$*
. C020$
ENABLE
. C019$
*.C019$*
INTERFACES SELECTION
. C008$
USB HID
USB VCP
. C006$

Auto-Sensing Mode (CCD) uses ambient light
to detect barcodes. The LED dims until a barcode
is presented to the scanner, then the LED brightens
to read the code.
If the ambient light condition is poor, the scanner
might not be working properly.
By default, the scanner will simply operate like
Trigger Mode which requires manual trigger.
To enable auto-sensing, place the scanner on an
Auto Hands-free Stand or disable Magnetic Switch
by scanning below configuration barcode.
GENERAL SETTINGS - READING MODE
GROUP-2
. F002$
TRIGGER MODE
. F007$
AUTO SENSING MODE (CCD)
The LED will light when the trigger is
pressed.
The LED will go off when the trigger is
released.
. F060$
The LED will turn on when the trigger is pressed.
The LED will turn off when the trigger is released.
Optimized to read bar codes from mobile phone
or other LED displays
MOBILE PHONE MODE
. F034$
MAGNETIC SWITCH OFF
. F035$
1. The Magnetic Switch is automatically activated when the scanner is in
Auto-Sensing Mode.
2. If Magnetic Switch is on, auto-sensing will be activated only when
the scanner is placed on an Auto Hands-free Stand.
3. If Magnetic Switch is off, the scanner will always be auto-sensing.
MAGNETIC SWITCH
NOTES:
MAGNETIC SWITCH ON

. D012$
. D013$
CR+LF
. D014$
TAB
. D015$
SPACE
. D010$
NONE
. D016$
ESC
. D011$
LF
.F019$
BEEP HIGH
.F022$
BEEP LOW
BEEP OFF
. F012$
.F018$
BEEP MEDIUM
GROUP-3
GENERAL SETTINGS -
BEEP TONE, VIBRATOR, TERMINATOR
BEEP TONE
VIBRATOR
TERMINATOR
1. For the USB HID interface the default terminator is CR.
2. For the USB VCP interface the default terminator is CR+LF.
3. Below is the position of Terminator among output data string:
[Preamble] [Symbology ID] [Barcode Length] [Barcode Data] [Postamble] [Terminator]
4. By default, with Preamble, Postamble, Barcode Length and Symbology ID
disabled, the scanner data output will be:
[Barcode Data] [Terminator]
NOTES:
CR
. D034$
. D035$
VIBRATOR OFF
VIBRATOR ON

PREAMBLE (16)
. A012$
POSTAMBLE (16)
. A013$
CLEAR PRE/ POSTAMBLE
. A011$
SEND DATA LENGTH ON
.D019$
.D020$
GROUP-4
SEND DATA LENGTH, PREAMBLE & POSTAMBLE.
SEND DATA LENGTH
PREAMBLE & POSTAMBLE ( PREFIX AND SUFFIX )
EXAMPLE:
SETTING PROCEDURE:
DATA FORMAT:
NOTES:
1. A PREAMBLE is a string of up to 16 characters added
to the beginning of a scanned barcode.
2. A POSTAMBLE is a string of up to 16 characters added
to the end of a scanned barcode.
3. Default value for both: None.
[Preamble] [Symbology ID] [Barcode Length] [Barcode Data] [Postamble] [Terminator]
Set PREAMBLE String as “ ## ”
POSTAMBLE String as “ $$ ”
STEP 1 : Scan : CLEAR PRE/ POSTAMBLE.
STEP 2 : Scan : PREAMBLE.
STEP 3 : Scan : “ # ” twice from Full ASCII Table.
STEP 4 : Scan : PREAMBLE.
STEP 5 : Scan : POSTAMBLE.
STEP 6 : Scan : “ $ ” twice from Full ASCII Table.
STEP 7 : Scan : POSTAMBLE.
SEND DATA LENGTH OFF
Table des matières
Autres manuels Ez One Shot Lecteur de codes-barres
Manuels Lecteur de codes-barres populaires d'autres marques

POSMicro
POSMicro Datalogic PowerScan D7100 Manuel utilisateur

Marson
Marson MT780 Guide de configuration rapide

NCR
NCR RealPOS Manuel utilisateur

Motorola
Motorola SE3300 Guide de configuration rapide

Element
Element P130BT Manuel utilisateur

Motorola
Motorola Symbol LS3008 Manuel d'installation et d'exploitation