eXact PipeCut V800 System Manuel utilisateur

PipeCut V00 Ventilation
System
EN Operating manual 5-16
patents: US 7,257,895, JP 4010941, EP 1301311, FI 108927, KR 10-0634113
Exact Tools Oy
Särkiniementie 5 B 64
00210 HELSINKI
FINLAND
Tel + 358 9 4366750
FAX + 358 9 43667550
www.exacttools.com


2
Exact PipeCut V00
Blade information for Exact PipeCut saws
Cermet (ceramic alloy tip) saw blades are very durable special saw blades.
Cermet V155 is designed specially for cutting thin sheet materials such as spiral ducts.
Cermet blades can be sharpened a few times.
Pipe Support V00
We recommend to use Exact Pipe Support V00 for to support the pipes when using Exact
Pipecut V00 pipe saw. These pipe holders are specially designed to be used with Exact
Pipecut V00 pipe saw. They can be used with pipes from 3’ (75 mm) up to ’ (00 mm).
2


2
A

2
Declaration of Conformity
We declare under our sole responsibility that the products described under “Technical Data” are in
conformity with the following standards or standardization documents: EN60745 according to the
provisions of the directives 2004/108/EC, 2006/42/EC.
For more information, please contact Exact Tools at the following address.
The technical ¿le is available at the address underneath.
The person authorized to compile the technical ¿le:
0DUNR7|UU|QHQ5'0DQDJHUPDUNRWRUURQHQ#H[DFWWRROVFRP
Helsinki, 1.9.2011
Seppo Makkonen, Managing director
Exact Tools Oy
Särkiniementie 5 B 64
FI-00210 Helsinki
Finland

2

5
Contents Translation of the original instructions english
Contents
6. Technical data
6. Package contents
Safety
7. Safety instructions
Operation
10. Functional description
10. Product features
11. Before operating the tool
11. Connection to the mains power supply
11. Precise setting of the cutting point
11. Setting the pipe on supports
12. Attaching the pipe saw to the pipe
12. Piercing the pipe wall
12. Sawing around a pipe
13. Overload protection
13. Straightness of cut and adjusting wheel
14. Installing and changing the saw blade
14. Service and maintenance instructions
16. Environment/Disposal
16. Guarantee/Guarantee conditions
16. Tips for users
Exploded view (separate attachment)
De¿nitions: Safety guidelines
The de¿nitions below describe the level of severity for each signal word. Please read the manual and
pay attention to these symbols.
DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in
death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in
minor or moderate injury.
NOTICE: Indicates a practice not related to personal injury which, if not avoided, may result
in property damage.
Denotes risk of electric shock.

6
Information english
Operating, safety, and servicing instructions
Please read this operating, safety, and servicing instructions carefully before using
the pipe saw. Also store this instruction book somewhere accessible to everyone
using the pipe saw. In addition to these instructions, always follow the of¿cial work,
health and safety regulations. The Exact PipeCut is meant for professional use only.
Technical data
Pipecut V00
Voltage 220-240 V or 110-120 V / 50-60 Hz
Power 1010W
No-Load speed 4000 r/min
Intermittent operation S3 25% 10min (2,5 min ON /7,5 min OFF)
Blade diameter 155 mm
Mounting bore 65 mm
Weight 6,6 kg
Range of use Ø 75 mm –00 mm
Max. pipe wall steel 1,5 / 6 mm
Protection class
/ II
Spindle lock YES
Speed preselection NO
Constant electronic control NO
Overload Protection YES
Reduced starting current NO
Vibration emission value ah 2,2 m/s2
Uncertanity ofVibration emission value K 1,5 m/s2
LWA (sound power) 98 dB
LpA (sound pressure) 87 dB
LpC (highest peak of sound pressure) 101 dB
The values given are valid for nominal voltages [U] of 230/240V. For lower voltage and models for
speci¿c countries, these values can vary.
Please observe the article number on the type plate of your machine. The trade names of the
individual machines may vary. Only for power tools without reduced starting current: Starting cycles
generate brief voltage drops. Interference with other equipment/machines may occur in case of
unfavourable mains system conditions. Malfunctions are not to be expected for system impedances
below 0.36 ohm.

7
Information english
Noise/Vibration Information
Measured values determined according to EN60745-1:2009 + A11:210 ja EN60745-2-3:210.
Wear hearing protection!
The test was performed using Ø315 thin wall spiral duct.
The vibration emission level given in this information sheet has been measured in accordance with
a standardised test given in EN 60745 and may be used to compare one tool with another. It may be
used for a preliminary assessment of exposure.
WARNING: The declared vibration emission level represents the main applications of the tool.
However if the tool is used for different applications, with different accessories or poorly
maintained, the vibration emission may differ. This may signi¿cantly increase the exposure level
over the total working period. An estimation of the level of exposure to vibration should also take into
account the times when the tool is switched off or when it is running but not actually doing the job.
This may signi¿cantly reduce the exposure
level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as:
maintain the tool and the accessories, keep the hands warm, organisation of work patterns.
Exact PipeCut V00 pipe saw
Package contents:
Please check the package contains the following items (page 4):
1. Pipecutting System case
2. Exact PipeCut V00 pipe saw
3. Operating instructions
4. Allen key 5 mm ¿xed to the
handle
5. Cermet blade 155 x 65 ¿tted
on the machine
1.
2.
3.
4.
5.
Table des matières