Eversolar Eversol-TL2100 Manuel utilisateur

Installation Instructions 1
Table of Contents
Table of Contents.........................................................................................................1
1 About this manual.....................................................................................................3
1.1 Validity ................................................................................................... 3
1.2 Target group .......................................................................................... 3
1.3 Retention of the manuals ...................................................................... 3
1.4 CE marking............................................................................................ 3
2 Safety instructions and regulations .........................................................................4
2.1 Technical rules....................................................................................... 4
2.2 Accident prevention regulations .......................................................... 4
3 Unpacking..................................................................................................................5
3.1 Scope of delivery.................................................................................... 5
3.2 Check for transport damage ................................................................ 5
4 Technical data ...........................................................................................................6
4.1 DC input data......................................................................................... 6
4.2 Output data............................................................................................ 6
4.3 Efficiency and safety equipment .......................................................... 7
4.4 General data........................................................................................... 7
5 Installation and startup ............................................................................................8
5.1 Selecting an appropriate place for installation ................................... 8
5.1.1 Dimensions and weight ................................................................................8
5.1.2 Ambient conditions ......................................................................................9
5.1.3 Position.......................................................................................................10

2 Installation Instructions
5.2 Installing the inverter.......................................................................... 10
5.3 Electrical connection ........................................................................... 13
5.3.1 Connection to the public grid (AC) ............................................................14
5.3.2 Connection to the PV generator (DC) ........................................................20
5.4 Startup.................................................................................................. 23
5.5 Communication ................................................................................... 23
5.5.1 Communication through RS232 .................................................................23
5.5.2 Communication through RS485 .................................................................25
5.6 Safety protection.................................................................................. 28
5.6.1 Grid voltage and frequency protection .......................................................28
5.6.2 Over temperature monitoring .....................................................................28
5.6.3 Ground fault current interruption (GFCI)...................................................29
5.6.4 Isolation fault detection ..............................................................................29
5.6.5 Earthing fault monitoring ...........................................................................29
5.6.6 Active anti-islanding protection .................................................................29
5.6.7 DC current injection monitoring.................................................................29
5.6.8 DC reverse polarity protection ...................................................................29
6 Contact.....................................................................................................................30

Installation Instructions 3
1 About this manual
1.1 Validity
This installation instructions describes the installation and startup of Eversolar New
Energy inverters of the type Eversol-TL2100, Eversol-TL3200, Eversol-TL4600,
Eversol-TL5400.
1.2 Target group
Only an authorized skilled electrician who is approved by the supply grid operator
may install and startup the inverter. This documentation contains important
information regarding installation of the system. Be sure to read this manual carefully
before installing.
1.3 Retention of the manuals
All documents for the Eversol and the installed components must be kept with the
system and available at all times.
1.4 CE marking
Type Normative reference
Eversol-TL2100/3200 EN50178, EN61000-6-1, EN61000-6-3, EN61000-6-2,
EN61000-6-4, EN61000-3-2, EN61000-3-3
Eversol-TL4600/5400 EN50178, EN61000-6-1, EN61000-6-3, EN61000-6-2,
EN61000-6-4, EN61000-3-12, EN61000-3-11

4 Installation Instructions
2 Safety instructions and regulations
2.1 Technical rules
Installation must be suited to the on-site conditions and comply with local regulations
and technical rules.
2.2 Accident prevention regulations
1. Only skilled electricians who have read and fully understood all safety
information contained in these operating and installation instructions, may install
the inverter.
2. The Eversol may only be operated with PV generators. Do not connect any other
source of energy to the Eversol.
3. All covers on the unit must remain closed during operation and all screws must be
tightened.
4. Be sure that the PV generator and inverter connect to the ground in order to
protect property and persons.
5. Before opening the cabinet, the solar inverter must be disconnected from the grid
and PV generator. You must wait at least five
minutes in order that the energy storage
capacitors are fully discharged during this
period after disconnecting the inverter from the
grid and PV generator.

Installation Instructions 5
3 Unpacking
3.1 Scope of delivery
Object Description Quantity
A Eversol inverter 1 pcs
B Ornamental plate 1 pcs
C MC IV-connectors including male
connector and female connector
2 pairs (for TL4600 and TL5400)
1 pair (for TL2100 and TL3200)
D AC connector 1 pcs
E Installation and operating
instructions 2 pcs
Please check all of the components carefully in the box. If something missing, contact
your dealer at once.
3.2 Check for transport damage
Thoroughly inspect the inverter upon delivery, if you discover any damage to the
packaging which indicates that the inverter may be damaged, inform the responsible
transport company immediately. We will be glad to assist you if required.

6 Installation Instructions
4 Technical data
4.1 DC input data
Type TL 2100 TL 3200 TL 4600 TL 5400
Max. PV-generator power [W] 2100 3200 4600 5400
Max. DC Voltage [V] 580 580 680 680
MPPT voltage range [V] 125 - 530 125 - 530 125 - 550 125 - 550
Turn off DC Voltage [V] 125 125 125 125
Max. DC current [A] 18 20 20 25
Nominal DC current [A] 16.2 18 18 22.5
Number of DC connection 1 1 2 2
Number of MPP trackers 1 1 1 2
DC-connection MC IV-connector
Turn on power [W] 10
4.2 Output data
Type TL 2100 TL 3200 TL 4600 TL 5400
AC connector Spring-clamp tech
Power connection Single phase
Rated AC power [W] 1800 2800 4000 4600
Max. AC Power [W] 1980 3080 4400 5060
Grid voltage range 187-264 V / 207-264
Grid frequency range 47.5-50.2 Hz / 47-50.5Hz
Rated current [A] 7.8 12.2 17.4 20.0
Max. current [A] 9.9 / 9.57 15.4 / 14.9 22 / 21.3 25.3 / 24.4
Power factor 0.99 0.99 0.99 0.99
Harmonic distortion (THD) at
rated output <2% <2% <2% <2%
Power consumption at night [W] <0.2 <0.2 <0.2 <0.2
Power consumption at standby [W] 6 6 6 6

Installation Instructions 7
4.3 Efficiency and safety equipment
Type TL 2100 TL 3200 TL 4600 TL 5400
Efficiency
Max. efficiency 97.1% 97.3% 97.5% 97.5%
Euro efficiency (at 360VDC) 96.5% 96.5% 97.0% 97.0%
MPPT adaptation efficiency 99.5% 99.5% 99.5% 99.5%
Safety equipment
Internal overvoltage protection Integrated
DC Insulation monitoring Integrated
Earth fault protection Integrated
Mains monitoring According to VDE 0126-1-1, GB, G83/1
Earth fault current monitoring According to VDE 0126-1-1, GB, G83/1
DC current monitoring According to VDE 0126-1-1, GB, G83/1
4.4 General data
Type TL 2100 TL 3200 TL 4600 TL 5400
Housing Aluminium housing for inside and outside installation
Operating temperature range -20°C to +60°C(up 40°C derating)
Relative humidity 0% to 98%, no condensation
Site altitude Up to 2000m without derating above sea level
IP protection type IP 65 according to IEC 60529
Isolation type Transformerless
Cooling concept Convection Regulated cooling
Noise level < 40 dBA
LED display 3
LCD display Backlight, 16×2 Character LCD
Data logger
Data communication interfaces RS232 and RS485
Standard warranty (option) 5 years

8 Installation Instructions
5 Installation and startup
5.1 Selecting an appropriate place for installation
Danger!
Danger of lethal injury due to fire or explosion!
The Eversol may become hot in normal operation.
Do not install the Eversol on flammable construction materials and
where flammable materials are stored.
Do not install the Eversol in areas where there is a risk of explosion.
Caution!
Danger of burns from hot housing components!
Install the Eversol so that it cannot be touched unintentional.
5.1.1 Dimensions and weight

Installation Instructions 9
Type Eversol-TL2100 Eversol-TL3200 Eversol-TL4600 Eversol-TL5400
Weight 19.9 kg 20.7 kg 21.4 kg 23.5 kg
5.1.2 Ambient conditions
1. The area where the units installed is as dry as possible in order to extend their
service life.
2. Ensure good access to the unit for installation or any service work that may later
be required.
3. Maintain the following minimum clearances around the unit:
4. If the wall is wooden, please add a thermal insulating layer between Eversol
inverter and the wooden wall.
5. Do not expose the Eversol to direct sunlight, in order to avoid power reduction
due to excessive heating. That the ambient temperature keeps below 40 oC will
guarantee the Eversol working in optimal status.
6. Provide better ventilation for Eversol to ensure that heat is dissipated adequately.
7. Install Eversol on a solid surface. Because of the noises made by the Eversol
when in operating, do not install the unit on plasterboard walls in order to avoid
audible vibrations.
Direction Minimum clearance
above 30 cm
below 30 cm
sides 30 cm

10 Installation Instructions
5.1.3 Position
1. The unit has been designed for vertical or tilted backwards by max. 15°
installation.
2. Do not install the Eversol forwards.
3. Never install it horizontally.
4. Installing at eye level makes it easier to operate and read the display.
5.2 Installing the inverter
Installing procedure:
a) Drilling holes
Drill four holes for the screws at the selected installation position. The space between
every two holes is shown in the figure below. Keep drilling vertical to the wall, and
don’t shake the drill to avoid holes tilting. The depth of the holes must be the same
and in the range of 55 mm ~ 60 mm. After removing the dust in the four holes,
measure the net depth of the holes. If the depth is deeper than 60 mm or less than 55
mm, the expansion tubes wouldn’t be installed and tightened.
Ce manuel convient aux modèles suivants
3
Table des matières