Everfine EMS61000-2A Manuel utilisateur

EMS61000-2A
ESD GENERATOR
USER’S MANUAL
V 4.02
EVERFINE Corporation (Stock Code: 300306)
ADD :Bldg.1 #669 Binkang Rd., Binjiang Hi-Tech
Zone, Hangzhou(310053), China
Tel :86-571-86698333
Fax :86-571-86696433
E-mail:Global@everfine.net
Globalservice@everfine.net
http://www.everfine.net
Copyright © EVERFINE, Copy or spread without authorization is prohibited.


EMS61000-2A User’s Manual
Copyright © EVERFINE, Copy or spread without authorization is prohibited. 1
Foreword
Thank you for purchasing the EVERFINE EMS61000-2A_30kV ESD Generator. This
user’s Manual contains useful information involving the instrument’s functions and
operating procedures as well as precautions that should be noticed during operation.
In order to use the instrument correctly, please read the manual carefully first, then put
it in a right place for quick references.
Notes:
The contents of this manual may be changed without prior notice.
Great effort has been made in preparation of this manual to ensure the accuracy of
its contents. If you have any questions or find any errors, please contact your
dealer or EVERFINE sales office.
If you have different understanding to this manual, please refer to the Technical
Service Department of EVERFINE.
Checking package contents
Please check the instrument carefully when you unpack the box for the first time. If
the instrument and related accessories are missing or appear abnormal, please contact
the dealer or EVERFINE immediately.
Warm notice to valued customers of EVERFINE
"Ensure the quality, insist on continuous improvement and make every customer
more satisfied" is the quality policy of EVERFINE. Therefore, the quality of
products and services provided by EVERFINE should be better than those have
been promised. If you have further suggestions or advices on our products and
services, please provide your feedback to our quality supervision department.
Your supervision is the motivation for us to move forward!

EMS61000-2A User’s Manua
Copyright © EVERFINE, Copy or spread without authorization is prohibited.
2
Copyright Statement
The copyright of this manual and the related information belongs to EVERFINE,
and it is protected by the copyright law of Peoples Republic of China and other
relevant international treaties. Copying, modifying, spreading, excerpting, backing up
and translating the whole or part contents of this manual by any company or personnel
without the written permission of EVERFINE is prohibited. Otherwise it will be
treated as infringement and the infringer will assume law responsibility and all loss of
EVERFINE. Any infringement related above can be traced back to the responsible
user by the unique product number printed in the manual.
If EVERFINE has signed a written agreement with user and the contents in the
agreement are in conflict with above terms, the contents in the written agreement have
preferential force effect.

EMS61000-2A User’s Manual
Copyright © EVERFINE, Copy or spread without authorization is prohibited. 3
Safety regulation
The following general safety precautions must be observed during all phases of
operations, including verification and repair. If the instrument is used in a manner not
specified in this manual, the function of this instrument may be hindered.
Flags below are adopted in the instrument.
High-voltage
Ground
Warnings
Never use the instrument in an explosive environment
Never use the instrument with explosive, gunpowder and firecracker around.
Using any electrical appliance in the explosive environment may be harmful.
Protecting Grounding
Ensure the instrument has been well grounded before turning on the power to avoid an
electric shock. Avoid taking the zero line of alternating current as the protective
grounding.
Power Supply
Make sure that the rated voltage of the instrument is equal to the voltage of the power
before connection.
Only lithium battery charger will be supplied and the lithium battery should be setted
when instrument is on operation.
Maintenance of the lithium battery
The battery should be charged/discharged every 3 months and it should be 60% power
left at least before store again. It should be charged within 24 hours if it is turned off
as the power shortage, otherwise, the battery would be damaged.
If the battery needs to be changed, please contact the retailer or EVERFINE.
Vents

EMS61000-2A User’s Manua
Copyright © EVERFINE, Copy or spread without authorization is prohibited.
4
Vents provide necessary cooling channel and should not be blocked when instrument
is on operation.
DO NOT take away any parts of the case
Since the instrument works at a high voltage, never remove the case of the instrument
or operate with the case opening.
Relative humidity
Never operate the instrument with wet hands or in an environment with high
humidity.
Transport
Take care when moving the instrument, and avoid collision, vibration or placing the
instrument upside down.

EMS61000-2A User’s Manual
Copyright © EVERFINE, Copy or spread without authorization is prohibited. 5
Contents
Foreword........................................................................................................................ 1
Copyright Statement.......................................................................................................1
Safety regulation.............................................................................................................3
Contents..........................................................................................................................5
Chapter 1 Overviews...................................................................................................... 7
Chapter 2 Specifications.................................................................................................8
2.1 Main specifications............................................................................................8
2.2 Conventional specification................................................................................ 9
Chapter 3 Panel Instructions.........................................................................................11
3.1 Front panel.......................................................................................................11
3.2 Rear panel........................................................................................................12
Chapter 4 Parameters Setting....................................................................................... 13
4.1 Interface and Parameters Setting..................................................................... 13
Chapter 5 Operation..................................................................................................... 22
5.1 Preparations..................................................................................................... 22
5.2 Power ON........................................................................................................ 22
5.3 Test parameter setting......................................................................................22
5.4 Starting test......................................................................................................22
5.5 Test termination............................................................................................... 23
5.6 Ending test....................................................................................................... 23
5.7 Altering information and its countermeasures.................................................23
Chapter 6 Verification...................................................................................................26
6.1 Verification basis............................................................................................. 26
6.2 Verification conditions.....................................................................................26
6.3 Verification of ESD high voltage output......................................................... 26
6.4 Verification of ESD gun.................................................................................. 27
Chapter7 Set-up in laboratory...................................................................................... 31

EMS61000-2A User’s Manua
Copyright © EVERFINE, Copy or spread without authorization is prohibited.
6
7.1 Test set-up in laboratories................................................................................31
Chapter 8 Driver installation........................................................................................ 35
8.1 Internet driver installation............................................................................... 35

EMS61000-2A User’s Manual
Copyright © EVERFINE, Copy or spread without authorization is prohibited. 7
Chapter 1 Overviews
EMS61000-2A ESD Generator is a highly reliable test system specially designed
according to the characteristics and requirements of ESD immunity test, with built-in
lithium battery and portable design. The maximum ESD voltage is up to 30 kV and
meets the highest severity level requirements of the standards, and provides an
accurate and satisfactory basis for the immunity assessment of electrical equipment
subject to electrostatic discharge.
EMS61000-2A ESD Generator meets requirements of standards such as ICE610
00-4-2, ISO10605. Equipped with different modules, EMS61000-2A ESD genera
tor can output international standard of ISO discharge models.
Main characteristics of EMS61000-2A:
1. With built-in lithium battery, portable and convenient to use.
2. Test voltage can up to 30KV maximum.
3. Identify the discharge resistance/capacitance modules intelligently to conduct
ESD test.
4. With discharge detection function, its sensitivity can be adjusted.
5. 7 inch LCD touch screen displayer and computer interaction interface.
6. With file systems, export and save test reports conveniently.
With RJ45 and USB communication Function.

EMS61000-2A User’s Manua
Copyright © EVERFINE, Copy or spread without authorization is prohibited.
8
Chapter 2 Specifications
2.1 Main specifications
(1) Electrostatic voltage
Polarity: positive/negative/alternate
Output voltage: up to 30.00kV±5%
Resolution: 0.01kV(10.00kV~30.00kV)
(2) Discharge interval
Contact discharge: 0.050s~30.0s
Air discharge: 1.0s~30.0s
(3) Discharge count
1~9999 when discharge interval is larger than 0.1s
1~100 when discharge interval is less than 0.1s
(4) Trigger mode
Manual: discharge one time when triggering the discharge gun or discharge button of
trigger module
Auto: continuously discharge as setting interval
External: discharge one time when receive an external trigger signal.
(5) Discharge network
Discharge network are listed in Table 2.1.
Table.2.1 Discharge network setting
Discharge
mode
Discharge
network
Max electrostatic
voltage
Standard
Remark
ISO
330Ω/150pF
±30.00kV
ISO10605
ESD gun
(optional)
330Ω/330pF
±30.00kV
ISO10605
2000Ω/150pF
±30.00kV
ISO10605/IEC61000-4-2
2000Ω/330pF
±30.00kV
ISO10605