Euramco Safety Ramfan EX150Li Manuel utilisateur

San Diego |Luxembourg |Dubai |Ningbo | Singapore
FlowPath™Control
Owner's Manual
ALL PURPOSE-BATTERY VENTILATOR
EX150Li

2
CONTENTS
Introduction .................................................................................................................................... 3
About Euramco ................................................................................................................ 3
Warning Labels and Safety Instructions ........................................................................ 4
Safety Checklist ................................................................................................................ 5
Unit Description .............................................................................................................................. 5
Parts List ............................................................................................................................ 5
Technical Specications .................................................................................................. 6
Dimensions ....................................................................................................................... 6
Main Interface .................................................................................................................. 7
Plug Type .......................................................................................................................... 8
Adjusting Angle ................................................................................................................ 9
Operational Modes ...................................................................................................................... 10
AC Operation .................................................................................................................. 10
DC Operation .................................................................................................................. 10
- Connection of Battery Pack ............................................................................ 10-11
- Battery Operation Procedures ...................................................................... 12-13
- Run Time ................................................................................................................ 13
- Charging Procedure .............................................................................................. 14
- The Fuel Gauge ..................................................................................................... 15
- Status Indicator Lights .......................................................................................... 16
- Battery Pack Protection ....................................................................................... 16
Storage/Transport Modes .......................................................................................................... 17
- Cord Storage ......................................................................................................... 18
- How to Store Batteries ......................................................................................... 18
- Cold Weather Operation ...................................................................................... 18
- Factors that aect Battery Life ............................................................................ 18
Maintenance and Disposal ......................................................................................................... 19
Accessories .................................................................................................................................... 19
Certication ................................................................................................................................... 20
Declaration of Conformity ......................................................................................................... 21

3
Introduction
Congratulations on your purchase of the high-end ventilator RAMFAN EX150Li.
WARNING!
Read this manual before starting for the rst time!
You now own an industrial ventilation unit that oers endless possibilities. Before using,
make sure that no damage was done to your ventilator during transport. If this is the case,
do not use the product and immediately contact your authorized Euramco dealer.
For your own safety and that of others, please read this instruction manual carefully before
using the unit.
Anyone involved in installing, operating or servicing the EX150Li must:
• Be a qualied, authorized professional.
• Strictly follow the instructions in this user manual.
Please take the time to read this manual carefully and thoroughly before operating the
ventilator. You should have a good knowledge of its operating conditions and all pertinent
product information.
After you have become familiar with this manual, we recommend that you keep a copy for
future use. All the information found in this manual is subject to change without notice.
Euramco reserves the right to modify and upgrade its range of products, with no obligation
to integrate these changes into products already sold.
If any questions arise concerning any of the information in this manual, Euramco Customer
Service must be consulted:
Euramco Group
2746 Via Orange Way
Spring Valley, CA - 91978
Ph 619.670.9590
Fx 619.670.7345
Toll Free: (800) 472-6326
www.euramco.com
About Euramco
Euramco Group is a leading manufacturer of portable ventilation solutions for the world’s
toughest job sites, with a primary focus on rotating machinery, engineered for superior
uid dynamics, and developing innovative industry-specic drive and control solutions.
Euramco Group sells to defense, reghting, hazardous area, and commercial safety
markets worldwide through ve locations globally.

4
Warning Labels and Safety Instructions
This is the safety-alert symbol.
When you see this symbol on your ventilator or in this manual, be alert to the potential for
personal injury or damage to your equipment. Be sure you understand all safety messages
and always follow recommended precautions and safe operating practices. Important
safety information is presented in this section and throughout the manual:
• Electrical shock hazard. Do not open the unit.
• DO NOT START with signs of visible damage.
• Ventilator is not intended for operation in explosive atmospheres.
• Wear ear protection when close by.
• Keep body parts and loose objects away from in take of ventilator.
• Do not move ventilator while in operation.
• Operate and repair by trained personnel only.
• Always use grounded plug and properly ground AC power receptacle.
• Heat sink becomes hot during charging to some extent. DO NOT touch. Do not place
items over heat sink area.
• Use with approved, good condition extension cord with the ground connector:
Wire Gauge Requirements per ft (m)
0-150 ft (0-50m) AWG 14 (2.5 mm2)
>150 ft (> 50m) AWG 12 (4 mm2)
HOT SURFACE
!
DO NOT TOUCH!
DO NOT PLACE ITEMS OVER
HEAT SINK AREA!
KEEP
FINS
CLEAR
HIGH VOLTAGE
DO NOT OPEN
No User Serviceable Parts
CAUTION!

5
Safety Checklist
√Always purchase from a Euramco's authorized dealer to ensure you are getting real
RAMFAN products, a full product warranty, and the best customer service.
√Flexible electrical cables connected to the equipment may not be used when damaged
√If you are unsure if the equipment is unsafe or if there are signs indicating that the
equipment is defective or damaged, report it and do not use it.
√ Check if the connectors, cables and its connections are in perfect condition.
√Do not use the equipment until the equipment has been fully assembled and
inspected for correct performance in accordance with the Owner's Manual.
√ Fully charge the batteries before the rst use! Safeguard your battery to ensure
continued high performance. It should be recharged after each use.
Unit Description
• The EX150Li is a multi-purpose 18"/46 cm ventilator powered by battery(s) or 90-250V
single phase, 50-60Hz AC power source. Its multipurpose frame can be congured for
PPV, smoke ejector or ducted ventilator use in both normal, horizontal and hanging
positions. The ventilator can be tilted from 0-30° within the frame in PPV mode.
• The motor controller and batteries are water-resistant, IP66 rated.
• The motor is a variable-speed BLDC motor controlled by a microprocessor integrated
with a power supply, dual battery chargers and an LED light driver.
• The EX150Li will run with one or two 52V 8Ah Lithium Ion Battery Packs. The batteries
may be swapped during operation.
• AC voltage can be applied while running on batteries and the ventilator will auto-switch
to AC power. Conversely, the AC power can be removed, and the unit will auto-switch
to battery power, if enough charge remains to power the ventilator.
• The integrated battery chargers will charge one or two fully discharged battery packs in
6 hours or less.
• LED scene lights are integrated into the ventilator shroud and have a 3-intensity
innite switch knob: high, low and o. Turn to change. The LED knob selects the scene
lights output level in a row. Clockwise Progression: O Full Half O.
• A Control Panel on the top of the unit controls all functions.
Parts List
Qty Description
1Ventilator EX150Li with Wheel Kit assembled
2Lithium-ion Battery Pack M1-52V 8Ah
1Power Cord

6
23"
17"
19" 21"
2.3"
4.3"
4.5"
7.8"
Technical Specications
Dimensions
Model EX150Li 18” (46 cm)
Motor 1.9hp (1.4kw)
Order #EL6500 EX150Li with wheel kit assembled (1), 52V 8Ah battery (2) and
power cord (1)
Runtime @ Full speed
DC: 45 min
DC Max: 30 min
AC: Unlimited
AC Input Multiple plug options available
Battery System 52V Lithium-Ion, 832Wh, 16Ah
IP Rating (Motor/
Battery
System/Controller)
IP66 / IP66 / IP66
Weight
2 packs
Without Battery
71 lbs (32 kg)
58 lbs (26 kg)
Dimensions (h x w x d) 23 x 21 x 19 in / 58 x 53 x 48 cm
Approvals
AMCA Vered Airow in
DC Power Supply
12,377 cfm (21,029 m3/hr)
AMCA Vered Airow in
AC Power Supply
11,896 cfm (20,211 m3/hr)

7
Main Interface
Control Panel:
AC PWR
PUSH FOR
WAKE | STOP PUSH FOR
MAX
L
R
DC PWR
DC MAX
FAULT
BAT. FAULT
NO PWR
STORAGE
MODE
Intellisense
TM
E3
LIGHTS SPEED
MAX
1
5
2
6
4
3
Number Symbol Indicate Function
1Wake Button / Emergency Stop Button
Press and hold WAKE button to start.
2Maximum Speed (DC) Button
Press MAX button for 2 seconds.
3LED Scene Lights
On, o, on high or on low.
4Speed Control
Controlled operation from 0 to full speed
5
Battery Status LED Lights
6
Ventilator Status LED Lights
See table below for details.
MAX
MAX
L
R
BAT. FAULT
AC PWR
DC PWR
DC MAX
FAULT
NO PWR
STORAGE
MODE
LIGHTS
SPEED
Color Status Description
O NO PWR Power is o
Green (Solid) AC PWR Ventilator is running on AC Power Supply
White (Solid) DC PWR Ventilator is running on DC Power Supply
White (Flashing) DC MAX Ventilator is running on Maximum speed - DC
Power Supply
Red (Flashing) FAULT Fault on the ventilator
Yellow (Flashing) STORAGE MODE Storage/Transport Mode

8
Plug Types
The EX150Li is suitable for worldwide applications. A voltage converter is not needed. The
unit includes a simple removable cord that allows the unit to operate up to 250 VAC:
Mainly used in Type Order #
USA, Canada, Mexico and
Japan
BEL-CUS-4762
Germany and France (and
most European countries)
E/F EL-CEU-4762
United Kingdom, Ireland,
Malta, Malaysia and
Singapore
GEL-83070-4762
Australia, New Zealand,
Papua New Guinea and
Argentina
IEL-84040-4762
China I EL-84640-4762
If it becomes necessary to use a power cord with another plug standard, order the power
cord that matches the electrical requirements of the country or area. The physical adapter
for the outlet is interchangeable for use in dierent countries and allows you to swap the
cable yourself into the socket.
This is an overview of electric plugs that are in use around the world. If you need a
special solution, just inform your local Euramco representative about the specic.
If you must change the power cord, please disconnect the cord from the electrical outlet
located on the back of the ventilator, as shown below, and replace with another:
How to Install and Remove Power
Cable:
• Cable snaps into place, easy one
hand usage.

9
Adjusting Angle
To adjust the ventilator angle to suit the desired position, unscrew the tilt adjustment knob
and adjust it at the desired angle upwards and then lock it in position by tightening the
knob. The shroud can pivot upwards to a range of 30°.
30°
Tilting Angle
30°
Pull the plug out itself, never by the cord or by wiggling it out of the outlet.

10
Connection of Battery Pack
DC Operation
• Plug the ventilator connector cable (blue) into the battery connector:
• Set the installation index on the battery with the cable, lining up with the cable
connector.
• Press the connector lock and rotate the blue piece clockwise (a quarter turn to the
right) in the most careful way possible.
• Align the edge of the battery pack with holder under the red line where it says, “Align
battery EX150Li” and rmly slide the battery in the direction of the arrow as shown in
the illustration until a loud click is heard.
Operational Modes
• Input Voltage. 90-250VAC, 50/60Hz
• The ventilator is capable of operating seamlessly in countries that supply electricity at
either 120V AC/60 Hz or 240V AC/50 Hz without manual adjustments by the user.
• Operation out of these limits can damage electrical components and will void the
warranty.
1. Connect the fan to an AC power source.
2. Status LED Light will automatically turn green, displaying the status “Ventilator is running
on AC Power Supply”.
3. Start the ventilator by using the Speed Control knob to the desired speed.
Note: You can keep the batteries on their location without charging the battery.
Battery Indicator Lights will turn o because there is no battery charging
when ventilator is running on AC.
4. When the fan is powered o, Status LED Light will automatically turn o after 1 hour and
the battery Indicator Lights will redisplay battery charge level of each battery pack detected.
The ventilator will begin charging the battery packs after 60 minutes of idle time.
5. Battery Packs do not charge while ventilator is running.
AC Operation
Table des matières
Autres manuels Euramco Safety Ventilateur