Essentim Scope 4 Manuel utilisateur

User Guide

Table of Content
Notes 5
Safety Instructions 6
Intended Use and User 7
Device Description 8
General Information 8
scope 8
Technical data 9
Transport and Storage 10
Commissioning 11
Device functions 12
Button 12
Switch on / switch off 12
Reset 12
User interaction with the scope 12
LED function 13
Find / Identify scope (App) 13
Memory (App) 13
Operating modes (App) 14
Magic Time (App) 14
Dynamic Mode 14
Static Mode 15
Logger Mode 15
Scope-designation (App) 15
Cleaning, Maintenance and Repair 16
Cleaning 16
Maintenance and Repair 16
Checking the measuring accuracy 16
Replacement of Gecko-strip 16
Malfunction 16
FAQs 17
Troubleshooting 18
3
user manual scope - version 1.1

Notes
Warning: This symbol is a warning. It describes a dangerous situation or indicates
safety risks.
Note: This symbol indicates important information.
This symbol of a crossed-out wheeled bin indicates that this device contains
electronic components and should not be disposed of with household waste in
accordance with Directive 2002/96 / EC (WEEE).
Legal information
No part of this document may be reproduced, electronically reproduced or distributed in any
form without a written permission of essentim GmbH.
essentim GmbH assumes no liability for any errors or omissions. The determination of valid
measurement results, conclusions and measures derived therefrom are solely the sole
responsibility of the user. essentim GmbH does not guarantee the correctness of the
measured values or measurement results. Furthermore, essentim GmbH assumes no liability
for errors or damage resulting from the use of the measured values determined.
Reserve technical changes. All rights reserved. essentim GmbH
Warranty and liability
The device complies with the essential health and safety requirements of the relevant EU
regulations and has been factory tested for proper function. When claiming the warranty, the
device number must be indicated (see product label on the device). Non-observance of the
manufacturer's instructions or any legal requirements or unauthorized modifications to the
equipment or unauthorized replacement of any part or accessory may significantly affect the
electrical safety of this product and may void the warranty. Any liability, property damage or
personal injury resulting from the device being used contrary to the instructions in this user
manual is excluded. Technical and formal design modifications due to continuous
development and product improvement are reserved at any time without prior notice. For
damages resulting from improper use, no liability is assumed and warranty claims expire as
well.
5
user manual scope - version 1.1

Safety Instructions
Read these safety instructions carefully before using the device and always keep the
instructions accessible!
Warning!
Always observe all safety instructions in this document!
A non-observance may result in personal injury or property damage!
Always keep the safety instructions and the user manual accessible.
●Observe all technical limits and storage conditions for the device.
●If the device is obviously damaged, it must be decommissioned and ensured.
●Do not try to repair or modify the device. For maintenance and repair, it must be returned
to the manufacturer or a specific location.
●Pre-commissioning, the safety instructions and the user manual must be read and
understood by the user. Only persons to whom this applies may put the device into usage.
●In addition to the safety instructions in this user manual, the basic work safety regulations
must be observed.
●The system is safe and reliable and complies with the relevant EU directives. In case of
improper use, the user, third parties or property may be damaged.
●Safety risks arising from used and scope-monitored biological material or samples are the
responsibility of the user.
●Maintenance or repairs may only be performed by the manufacturer or
persons/companies commissioned by the manufacturer.
●Do not use the device in potentially explosive atmospheres, aggressive atmospheres or
explosion protection zones.
●The device is not a toy. Keep away from children and animals.
●Never immerse the device completely in liquid.
●Avoid ingress of liquid through the charging interface.
●Protect the device from direct sunlight.
●Do not remove safety signs or labels from the device. Keep all safety signs and labels in a
readable condition.
●Do not open the device with a tool.
●The product should not be sterilized.
6
user manual scope - version 1.1

Intended Use and User
The scope was developed to monitor biological samples in the laboratory. For this, the scope
is attached directly to the respective vessel or sample and carried along by the complete
process. In addition to use in the laboratory, the scope can also be used for transport
monitoring, as long as the safe operating conditions are not surpassed or under-passed.
Warning!
Always follow the stated safe conditions of use!
●The operating temperature is -20 °C to + 60 °C with non-condensing humidity up to 100 %
and an ambient pressure of 0.8 bar to 1.2 bar.
●Scopes should be used as a stationary or mobile measuring unit.
●Scopes must be charged at room temperature (but in any case between 0 °C and 40 °C).
●Only use essentim approved cables and extension in conjunction with the scope.
●Avoid mechanical stress on the scope, damage to the housing may damage the
lithium-polymer battery. This can lead to leakage of liquids from the battery or short
circuits and temperature development.
●For transport monitoring, the transport destination of the respective transport service
provider with regard to lithium-containing batteries must be considered. For more
information contact your transport service or essentim GmbH.
The typical user is e.g. a trained laboratory assistant / assistant / technician / student. Every
user must read and understand the safety and the user manual.
7
user manual scope - version 1.1

Device Description
General Information
The scope is a wireless sensor with a recording function (datalogging function). The data is
transmitted in real time via Bluetooth broadcasts and stored in parallel in the local memory.
The scope measures temperature, humidity, vibration and movement, brightness and
barometric pressure. Through an interface, the scope can be extended by various
measurement parameters. The scope has a button for switching on and off and interaction
during operation.
Through an electrostatic adhesive strip ("Gecko-strip"), the scope can be attached to smooth
surfaces and removed without leaving any residue easily.
To achieve a 24/7 monitoring the scope can be used in combination with the wireless sensor
infrastructure of essentim. This requires at least one essentim gateway. Further information
can be found at www.essentim.com/en/essentim-sensors.
scope
8
user manual scope - version 1.1

Technical data
Producer
essentim GmbH
Model
scope version 4
Type
Wireless multi-parameter-sensor
Power supply for charging
5V DC (min. 50mA)
Battery type
Lithium-Polymer-Battery, 35mAh,
rechargeable, firmly installed
Operating conditions
(EN / IEC 61010-1)
- Operating location
-Operating temperature
-Humidity
-Other
Terms for storage and charging process
-Temperature
-Humidity
-Storage
Inside, in a transport box with securing, not for outdoor
use, no use or storage in potentially explosive atmosphere
-20 °C to 60 °C
Maximum 100 % relative humidity, non-condensing
Do not expose to chemicals or mechanical stress.
The product must not be sterilized!
Observe the cleaning instructions in the user manual to
avoid damage.
0 °C to 40 °C
10 % to 50 %
Keep away from frost and heat, prevent from contact with
hazardous materials, storage in a place protected from
dust and direct sunlight
EMV
DIN EN 61326-1; VDE 0843-20-1:2013-07
Other conformities
RoHS, FCC, IC, CE MIC, KC
Protection (EN 60529)
non
Sensor specification and measuring range
-Temperature
-Air humidity
-Barometric pressure
-Brightness
-Motion
-20 °C to 60 °C (+/-0,3K)
0 % to 100% (+/- 2%)
300 hPa to 1100 hPa (+/- 1hPa)
0 % to 100 % (dark to very bright)
Stop detection, motion detection
Interfaces
BLE (BT4.2), USB-C for charging and connecting sensor
extensions (no USB)
Dimensions
43 x 16 x 10,5 (in mm)
Weight
Ca. 10 g
9
user manual scope - version 1.1

Transport and Storage
Warning!
Improper transport can lead to personal injury and property damage. Observe
all instructions for safe transport.
The scope must be secured against vibrations during transport. The scope must be positioned
so that the button is not mistakenly pressed.
Always take into account the transport guidelines of your transport service provider when
transporting lithium-containing batteries. Information can be obtained directly from the
transport service provider or contact essentim.
Unused scopes should be stored with a charge of about 30 %.
Note
It is recommended to store the scopes no longer than 3 months without
charging. Long-term storage can shorten the maximum battery life.
Terms for storage and charging process
-Temperature
-Humidity
-Storage
0 °C to 40 °C
10 % to 50 %
Keep away from frost and heat, prevent from contact with
hazardous materials, storage in a place protected from
dust and direct sunlight
10
user manual scope - version 1.1
Table des matières