Installation
8 Care@Home™ Stationary Panic Button User Guide
6. Press the PAIRING button, located on the right edge of the front of the CP, for five (5) seconds. The
CP beeps and the ring, around the EMERGENCY button, lights up in Blue with a circular movement
effect.
7. Holding the SPB, move at least 2 m (~6 ft. 7 in.) from the CP.
8. Press the Panic button on the SPB.
9. Ensure that the pairing process is successful. The process can have the following results:
If the pairing process is successful, the CP beeps and the ring, around the CP EMERGENCY
button, blinks Blue three times.
If the pairing process is not successful, the CP beeps and the ring lights up Red for two
seconds.
If the peripheral device is already paired, the CP beeps and the ring lights up alternating
between Blue and Red.
If no additional peripheral devices can be integrated, as when the CP memory is full, the CP
beeps and the ring lights up Red.
The CP returns to its previous operation mode automatically following the pairing process.
10. Install the SPB as follows:
a. Identify the location for installing the SPB, according to the recommendations in section 2.2 on
page 4.
b. Clean the surface of the mounting location thoroughly. Make sure the location is dry.
c. Peel off the protective strips from the mounting tape, as shown in Figure 10 on page 14.
d. Press the SPB into place.
NOTE: Refer to the section “Using Screws” of Appendix A,on page 15, for
information about installing the SPB using screws.
3.2. Testing the SPB
To check that the SPB has been installed correctly, perform the following procedure:
1. Press the Panic button on the SPB.
2. Verify that the LED on the SPB lights up Red.
3. Verify that the CP EMERGENCY button on the CP flashes Red and a vocal announcement declares
that the emergency alarm has been triggered.
4. Verify that the monitoring station receives an emergency message from the CP.