01
Rev. 31.10.18 MANUAL FOR MOUNTING SYSTEM WITH TRUSSHOOK FOR PITCHED ROOF WITH TILES
1. Introduction
This manual describes the installation of the ClickFit Evo mounting system with trusshook on a pitched roof with roof tiles
(for solar panels in portrait and landscape layout).
Read the manual carefully so that you are aware of its entire contents. Follow the instructions in the manual meticulously.
Always execute the actions in the correct sequence.
Store the manual in a safe and dry place. If you lose the manual you can request a new copy from Esdec B.V.
2. General installation conditions
General
Failure to comply with the instructions in this document can result in the nullication of all guarantee and product liability claims.
The information, comments and recommendations in this document are binding and must be checked for completeness and current
relevancy. Esdec BV reserves the right to alter this document without further announcement.
Stability and condition of the roof
The roof must be in good condition and sufciently strong to bear the weight of the solar panels and the additional materials, wind and
snow loads. Check the stability of the roof and alter the roof/construction where necessary. If in doubt, use a construction rm. Ensure
that the load reserve of the roof is not exceeded either completely or at specic points.
Safety warnings
• Mounting the ClickFit Evo mounting system must always be executed by qualied technical personnel (minimum of 2 professionally
qualied persons).
• The addition or omission of parts can have a detrimental effect on the function and is advised against in the strongest terms!
• The roof must be clean, dry, even and free of algae, etc. for placement of the solar panels.
• Avoid mounting if there is a strong wind and a wet roof surface.
• Always work on a pitched roof with a safety harness and safety nets and edge safety if necessary.
• Slide roof tiles upwards so that gaps are created in which you can place your feet. Attention!: Never stand in the gutter.
• Wear shoes with reinforced toecaps and strong anti-slip soles.
• Always wear the correct protective clothing when executing the work.
• Always use a lifting/hoisting installation when moving the material (solar panels, etc.).
• Always place a ladder on a strong and stable surface.
• Always place the ladder at an angle of approximately 75º and allow it to protrude above the edge of the roof.
• If possible, secure the top of the ladder with a rope or tensioning strap.
• Preferably work in accordance with the “working safely on roofs” manual.
• Attention: The trusshook must be placed against the roof batten!
Range of application ClickFit Evo
• Solar panels of all brands and models with a frame height between 30 and 50 mm with a maximum dimension of 2 x 1m (2m2) per
solar panel.
• Range of adjustable trusshook (tiling batten thickness + roof tile thickness): 37 - 62mm
• Wind zone (1 to 3)
• Roof height (3 - 12 m). Contact your supplier if your roof is higher
• Roof covering type: Pitched roof with roof tiles
• Roof incline: Between 15 - 60 degrees (35 degrees is optimum)
Edge zone
The distance from the solar panels to the roof ridge and the gutter must be a minimum of 30 cm, in consideration of the wind load.
The distance from the solar panels to the side of the roof must be a minimum of 30 cm. Solar panels may not be placed here either
completely or partially.