technical data
Water Inlet Connecon (Hot / cold)
1/2” BSP (DN 15mm)
5/8” BSP (In-wall recessed SBA)
Working Pressure Range
10-1200 kPa (Jumper valve, spring loaded valve)
50-800 kPa (Ceramic Disc)
Recommended Working Pressure Range* 150-500 kPa max*
Flow Rate Pre-rinse spray gun 4 L/min
Pot ller 8 L/min. supplied standard
Operang Temperature Range
0 - 95 °C (Jumper valve)
0 - 85 °C (Spring loaded valve, incl. pre-rinse spray gun)
0 - 75 °C (Ceramic Disk)
WATER SERVICES
Plumbing Code of Australia: Part B1 Cold Water
Services AS / NZS 3500.1-2003 Water Services;
• Secon 1.6(a) Facilies for people with Disabilies
• Secon 3.3.2 Pressure at outlets (min 50kPa)
• Secon 3.3.4 Maximum pressure within
buildings (500kPa stac)
• Secon 3.4 Velocity Requirement (Max 3.0m/s)
• Secon 16 Tesng and Commissioning; Flushing,
Hydrostac tesng, cleaning and disinfecon of
water services.
HEATED WATER SERVICES
Plumbing Code of Australia: Part B2 Heated Water
Services
AS / NZS 3500.4-2003 Heated Water Services;
• Secon 1.9 Water Temperature
1.9.1 Storage Temperature
1.9.2 Sanitary xtures delivery temperature
1.9.3 Acceptable soluons for control of delivery
temperatures
• Secon 10 Heated Water Services for People
with Disabilies
• Secon 11 Tesng and Commissioning
installation compliance
*Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA), AS/NZS3500
and the manufacturer’s instrucons.
Installaons not complying with PCA, AS/NZS 3500 or the manufacturer’s instrucons may void the product
and performance warranty provisions.
This product must be installed and commissioned by a qualied plumber. The following clauses must be
observed for a compliant installaon and correct operaon of Enware tapware.
For use with potable water only.