INSTALLATION
AFTER THE WALL IS FINISHED ...
MOUNTING THE SENSOR PLATE
The stainless steel sensor unit is always mounted
ush to the wall. Feed the power pack cable
through the conduit and make the connecon
to the sensor by joining the line plug and socket,
observing the polarity of the plug.
Connect exible inlet hose for the spout to
solenoid again, turn on water and test for leaks.
Test the tap again for correct operaon.
Important:
Before xing the plate in place, apply a bead of
silicon sealant across the top of the plate and
down the sides to prevent moisture geng
between the wall face and the plate.
Fix the sensor panel using four screws provided.
Take care not to put hands in front of the lens
when mounng the plate, as the tap is now
operaonal and will acvate.
TESTING
Turn on the power to the unit and test the unit.
Wave-On Wave-O Model: Wave the back of
your hand through the beam to turn the water
on, and again to turn the water o.
Time-Flow: Simply place your hand in front of
sensor, and acvate the sensor.
For more details on sensor funcons, refer to
“Sensor Program”.
WARNING:
Sensor components are fragile and
sensive. Do not force the sensor
plate to t onto wall, or aempt to
disassemble sensor components, as this
could result in damage to sensor.
TESTING
Turn the water on, and check for leaks.
Connect all electrical components together temporarily, turn the power on and test the tap.
Once correct operaon of the tap is conrmed, disconnect the sensor plate cable and turn o the
power to the transformer. Turn water o at the isolaon valve and disconnect the spout & sensor
plate. The tap is now ready for sheeng or nishing of the wall.