ennoLogic eM870M Manuel utilisateur

eM870M Insulation Multimeter
User Manual

ennoLogic eM870M Insulation Multimeter
Made in China
User Manual Version 1.1. Revised 1/5/2018.
© 2018 ennoLogic®. All rights reserved.
https://ennologic.com

ennoLogic eM870M Insulation Multimeter
Table of Contents
Table of Contents
1. Precautionary Safety Measures........................................................................................................................1
1.1 Important Note: Limited Liability...............................................................................................................................1
1.2 Meter Safety Standards...............................................................................................................................................1
1.3 Warnings.....................................................................................................................................................................2
2. Instrument Description.....................................................................................................................................4
2.1 Features Overview ......................................................................................................................................................4
2.2 Main User Elements....................................................................................................................................................5
2.3 LCD Display.............................................................................................................................................................10
3. Function Descriptions .....................................................................................................................................13
3.1 General Functions.....................................................................................................................................................13
3.1.1 TRUE RMS Measurement ................................................................................................................................................ 13
3.1.2 Manual ranging and auto range mode ............................................................................................................................... 13
3.1.3 Maximum, Minimum and Average Value Measurements................................................................................................. 14
3.1.4 Automatic Shutdown......................................................................................................................................................... 15

ennoLogic eM870M Insulation Multimeter
Table of Contents
3.1.5 Low Battery Voltage Detection......................................................................................................................................... 15
3.1.6 Backlight ........................................................................................................................................................................... 15
3.1.7 Data Hold .......................................................................................................................................................................... 15
3.2 Measurement Functions............................................................................................................................................16
3.2.1 AC Voltage Measurement................................................................................................................................................. 16
3.2.2 DC Voltage Measurement ................................................................................................................................................. 18
3.2.3 DC mV/AC mV Measurement .......................................................................................................................................... 20
3.2.4 Frequency & Duty Cycle of Digital Signals and Temperature Measurements.................................................................. 22
3.2.5 Diode and Continuity Tests............................................................................................................................................... 24
3.2.6 Resistance Measurement ................................................................................................................................................... 26
3.2.7 Capacitance Measurement................................................................................................................................................. 28
3.2.8 DC and AC μA Current Measurement .............................................................................................................................. 30
3.2.9 DC and AC mA Current Measurement ............................................................................................................................. 32
3.2.10 Insulation Resistance Measurement ................................................................................................................................ 34
3.2.11 Frequency Measurement of Sinusoidal Signals............................................................................................................... 36

ennoLogic eM870M Insulation Multimeter
Table of Contents
4. Technical Specifications..................................................................................................................................37
4.1 General Specifications ..............................................................................................................................................37
4.2 Measurement Specifications.....................................................................................................................................38
4.2.1 AC Voltage........................................................................................................................................................................ 38
4.2.2 DC Voltage........................................................................................................................................................................ 38
4.2.3 AC Current ........................................................................................................................................................................ 39
4.2.4 DC Current ........................................................................................................................................................................ 39
4.2.5 Resistance.......................................................................................................................................................................... 39
4.2.6 Capacitance ....................................................................................................................................................................... 40
4.2.7 Diode................................................................................................................................................................................. 40
4.2.8 Frequency of Square Waveforms ...................................................................................................................................... 40
4.2.9 Temperature....................................................................................................................................................................... 40
4.2.10 Frequency of Sinusoidal Signals ..................................................................................................................................... 40
4.2.11 Duty Cycle....................................................................................................................................................................... 41
4.2.12 Insulation Resistance....................................................................................................................................................... 41

ennoLogic eM870M Insulation Multimeter
Table of Contents
5. Maintenance.....................................................................................................................................................42
5.1 General Maintenance ................................................................................................................................................42
5.1 Battery Replacement.................................................................................................................................................42
5.2 Fuse Replacement.....................................................................................................................................................43
6. Accessories........................................................................................................................................................44

ennoLogic eM870M Insulation Multimeter
Precautionary Safety Measures
1
1. Precautionary Safety Measures
1.1 Important Note: Limited Liability
Cascadia Innovations is the exclusive distributor of all ennoLogic®products. Except as explicitly stated, Cascadia
Innovations is not liable for direct, indirect, incidental, or other types of damages arising out of, or resulting from the
use of this product. By using the eM870M you agree to hold ennoLogic®and Cascadia Innovations harmless for any
and all consequences of the use of this product or application of data from the use of this instrument.
1.2 Meter Safety Standards
The insulation multimeter eM870M was designed and manufactured according to the safety requirements specified in
the IEC61010-1 standard for electronic test instruments and hand-held digital multimeters. Its design and
manufacturing comply with Measurement Category 1000V CAT III of IEC 61010-1 and Pollution Degree 2.
The meter conforms to the following European Union directives: 89/336/EEC (Electromagnetic Compatibility EMC),
73/23/EEC (Low Voltage Directive LVD) and 93/68/EEC (CE Mark).

ennoLogic eM870M Insulation Multimeter
Precautionary Safety Measures
2
1.3 Warnings
Before first use of the meter please check if the housing shows any cracks or if any plastic parts are missing, and
check whether the test leads are damaged or have any exposed metal. The meter must be used only if there are no
problems or damage affecting insulation.
Please read the operating instructions and safety measures sections in this manual carefully. Using the meter
outside the methods specified in this manual may cause damage to the meter or other equipment.
Do not use the meter or test leads if they appear to be damaged.
Do not operate the meter around explosive gas, steam, vapor or dust.
Caution when working with voltages above 60V DC or 30V AC rms, there is the possibility of a shock hazard.
Avoid direct body contact with ground during measurement, or with any metal object that may be at ground
potential. The body should be kept insulated from ground with dry insulating shoes, insulating pads or insulating
clothes.
When performing measurements with a test probe make sure you grab the probe behind the protective plastic ridge
designed to protect your fingers from making accidental contact with the probe tip or circuit.

ennoLogic eM870M Insulation Multimeter
Precautionary Safety Measures
3
Do not attempt to measure voltages above 1000V AC or 1000V DC, the meter may get damaged and/or the
operator’s safety may be threatened if the maximum limit for voltage measurements is exceeded.
To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon
as the battery indicator appears.
Before installing or replacing the battery, disconnect test leads and/or any connectors from any circuit under test,
turn the meter off and remove test leads from the input terminals.
Use AAA batteries and make sure to insert them with the proper polarity.
When measuring voltage or current be certain that the test leads are connected to the correct input terminals.
Any adjustments, maintenance or repair work on the meter should only be performed by qualified personnel.
If any faults or abnormalities are observed, take the instrument out of service and ensure that it cannot be used
until it has been checked out.
If the meter is not going to be used for an extended period of time, take out the batteries and do not store the meter
in high temperature or high humidity environments.

ennoLogic eM870M Insulation Multimeter
Instrument Description
4
2. Instrument Description
2.1 Features Overview
5000 counts digital display
AC Voltage and DC Voltage measurements up to 1000V
DC measurement accuracy as low as 0.1%
High resolution: resistance 0.1Ω, voltage 10µV
Digital frequency and sinusoidal frequency measurement, as well as duty cycle
Capacitance measurements, range 0.1nF to 1000µF
AC True RMS measurements
Maximum and minimum values
Insulation resistance measurement, range: 50KΩ to 2GΩ
Automatic shutdown or continuous-ON mode
Backlight
Overload protection
Secondary plastic shell with insulating performance of 1000V CAT III
Table des matières
Autres manuels ennoLogic Multimètre
Manuels Multimètre populaires d'autres marques

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 Manuel utilisateur

PeakTech
PeakTech 4000 Manuel d'utilisation et d'entretien

YOKOGAWA
YOKOGAWA 90050B Manuel utilisateur

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 Manuel utilisateur

Fluke
Fluke 8846A Manuel d'utilisation et d'entretien

Tempo Communications
Tempo Communications MM200 Manuel utilisateur