Enginko MCF-LW12TERPM Manuel utilisateur

2022/09/11 20:17 1/2 manual_mcf-lw12terpm
e n g i n k o . s u p p o r t . c e n t e r - https://www.enginko.com/support/
Table of Contents
MCF-LW12TERPM Operating Manual 1 .........................................................................................
1. Description 1 ................................................................................................................................
2. Overview 2 ....................................................................................................................................
2.1 Technical data 2 .........................................................................................................................
2.2 Installation 3 ..............................................................................................................................
2.3 Configuration 4 ..........................................................................................................................
2.4 Power ON/OFF 4 .........................................................................................................................
2.5 Backup battery 6 ........................................................................................................................
2.6 Firmware update 7 .....................................................................................................................
3. Measures 7 ....................................................................................................................................
3.1 Period 7 ......................................................................................................................................
3.2 Temperature 8 ...........................................................................................................................
3.3 Pressure 8 ..................................................................................................................................
3.4 Humidity 9 .................................................................................................................................
3.5 PM 9 ...........................................................................................................................................
4 LoRaWAN network 9 .....................................................................................................................
4.1 Activation 10 ..............................................................................................................................
4.2 Other settings 11 .......................................................................................................................
5 Passwords 13 .................................................................................................................................
6 Configuration file 15 .....................................................................................................................
6.1 Multi devices configuration 16 ...................................................................................................
7 LoRaWEB Tool 17 ...........................................................................................................................
8 Payload 18 ......................................................................................................................................
9 Maintenance 18 .............................................................................................................................
10 Ordering code 19 ........................................................................................................................
11 Declaration of conformity 19 ....................................................................................................
12 Contacts 19 ..................................................................................................................................

Last update: 2022/02/08
12:03 manual_mcf-lw12terpm https://www.enginko.com/support/doku.php?id=manual_mcf-lw12terpm&rev=1644318191
https://www.enginko.com/support/ Printed on 2022/09/11 20:17

2022/09/11 20:17 1/19 manual_mcf-lw12terpm
e n g i n k o . s u p p o r t . c e n t e r - https://www.enginko.com/support/
MCF-LW12TERPM Operating Manual
Important safety information
Read this manual before attempting to install the device! Failure to observe
recommendations included in this manual may be dangerous or cause a violation of the
law. The manufacturer will not be held responsible for any loss or damage resulting from
not following the instructions of this operating manual.
Do not dismantle or modify in any way.
The device is not intended to be used as a reference sensor, and enginko Srl will not be held
liable for any damage which may result from inaccurate readings.
Avoid mechanical stress
Do not use any detergent or alcohol to clean the device.
Disposal information for users
Pursuant to and in accordance with Article 14 of the Directive 2012/19/EU of the
European Parliament on waste electrical and electronic equipment (WEEE), and
pursuant to and in accordance with Article 20 of the Directive 2013/56/EU of the
European Parliament on batteries and accumulators and waste batteries.
The barred symbol of the rubbish bin shown on the equipment indicates that, at the end of its useful
life, the product must be collected separately from other waste.
Please note that the lithium batteries must be removed from the equipment before it is given as
waste and disposed separately. To remove the batteries refer to the specifications in the user manual.
For additional information and how to carry out disposal, please contact the certified disposal service
providers.
1. Description
The MCF-LW12TERPM is a solar powered sensor that reads temperature, humidity, pressure and PM
(PM1, PM2.5, PM10) and sends collected data over the LoRaWAN® network. Ideally suited for a wide
range of applications such as weather stations, urban monitoring, air quality, industrial,
environmental or farming projects.

Last update: 2022/02/08
12:03 manual_mcf-lw12terpm https://www.enginko.com/support/doku.php?id=manual_mcf-lw12terpm&rev=1644318191
https://www.enginko.com/support/ Printed on 2022/09/11 20:17
2. Overview
2.1 Technical data
CPU Cortex M0+
EEProm 32Kb
Flash 64k
Encryption AES 128 bit
Class A LoRaWAN® 1.0.2 stack EU868, AS923, AU915, US915
Temperature -30 ÷ 70°C (0 ÷ 65°C ±1.0°C)
Humidity 0% to 100% will following error @25°C:
From 0% to 20% ±5%
From 20% to 80% ±3%
From 80% to 100% ±5%
Pressure 300 ÷ 1100hPa (±1.0hPa)
PM sensor PM1\PM2.5 ±10%, PM10 ±30%
NFC for IoT node setup, FW upgrade and data reading
main 860mAh Li-Ion rechargeable battery and a 7200mAh Li-SOCl2 primary battery as backup
> 30 days of operation with no sun with main battery fully charged (20 hours of of direct
sunlight)
Wall or pole mounting
Storage temperature range -30 + 80°C

2022/09/11 20:17 3/19 manual_mcf-lw12terpm
e n g i n k o . s u p p o r t . c e n t e r - https://www.enginko.com/support/
Working temperature range -30 + 60°C
Protection class IP33
Dimensions (approx) L x H X P: 210 x 310 x 200mm
Weight 2.5kg
2.2 Installation
The installation must take place in a place where the LoRaWAN® signal coverage is good (SF=7
optimal, SF=12 weak).
Place the sensor in a way that the solar panel is not in the shade and exposed to the greatest possible
amount of sunlight during the day.
2.2.1 Pipe mount
Mount the sensor on pipe as in picture:
2.2.2 Wall mount
Mount the sensor on wall as in picture:

Last update: 2022/02/08
12:03 manual_mcf-lw12terpm https://www.enginko.com/support/doku.php?id=manual_mcf-lw12terpm&rev=1644318191
https://www.enginko.com/support/ Printed on 2022/09/11 20:17
2.3 Configuration
To deploy the sensor, download the latest LoRa Tool Android App to setup LoRaWAN® credentials
and other preferences :
Always validate your settings by reading the NFC data after the sensor has restarted.
Configuration can be done only via NFC.
No USB port available for the user.
2.4 Power ON/OFF
The sensor is shipped completely off to prevent battery consumption during storage. It is therefore
necessary to carry out a first power-on prior to commissioning.
Move the NFC antenna of the mobile (the exact position varies depending on the model of the
smartphone) to the sensor antenna, in the area shown in the figure:

2022/09/11 20:17 5/19 manual_mcf-lw12terpm
e n g i n k o . s u p p o r t . c e n t e r - https://www.enginko.com/support/
At the first power-on, sensor will take from 1 to 5 minutes to give an effective measure of PM.
In case of long period inactivity, if necessary, is possible to shut-off again the sensor to prevent
battery consumption, via downlink or with LoRa Tool App:

Last update: 2022/02/08
12:03 manual_mcf-lw12terpm https://www.enginko.com/support/doku.php?id=manual_mcf-lw12terpm&rev=1644318191
https://www.enginko.com/support/ Printed on 2022/09/11 20:17
2.5 Backup battery
This sensor contains lithium battery, which must be disposed of separately.
MCF-LW12TERPM is provided with one Li-SOCl2 battery pack as backup:
Code Description
MCF-1S2PE 7200mAh battery pack
With this battery the sensor can run for 1 year with the rechargeable battery completely discharged.
Battery replacement can be done only by enginko or trained personnel.

2022/09/11 20:17 7/19 manual_mcf-lw12terpm
e n g i n k o . s u p p o r t . c e n t e r - https://www.enginko.com/support/
2.6 Firmware update
Save the firmware file (.FW) on the smartphone, and upload it with LoraTool App:
During the update, do not move the smartphone untill the end message.
3. Measures
3.1 Period

Last update: 2022/02/08
12:03 manual_mcf-lw12terpm https://www.enginko.com/support/doku.php?id=manual_mcf-lw12terpm&rev=1644318191
https://www.enginko.com/support/ Printed on 2022/09/11 20:17
Period is the interval (in minutes) between one measure and the next one. The sensor sends one
measures for every transmission. Value can be between 15 and 65535 minutes (default: 30 minutes).
Period interval can be set with App or with downlink command.
3.2 Temperature
3.3 Pressure
3.3.1 Altitude compensation
When the sensor is not installed at the sea level, the reading of barometric pressures at other
elevations must be compensated. Set the right altitude value with LoRa Tool app:
Value can be from -300 to 3000 meters.
Altitude can also be set with downlink command.
Table des matières
Autres manuels Enginko Accessoires

Enginko
Enginko MCF-LW12TERWP Manuel utilisateur

Enginko
Enginko EGK-LW20L00 Manuel utilisateur

Enginko
Enginko EGK-LW20W00 Manuel utilisateur

Enginko
Enginko MCF-LW12TERWP Manuel utilisateur

Enginko
Enginko MCF-LW12CO2E Manuel utilisateur

Enginko
Enginko mcf88 MCF-LW12TERWP Manuel utilisateur

Enginko
Enginko mcf88 MCF-LW12VOC Manuel utilisateur